Setting up a DMX connection: 

 

DMX is a standardized transmission protocol that allows all DMX

-compliant models of the various 

manufacturers  to  be  connected  to  one  another  and  controlled  by  a  single  mixer.  Free  DMX  data 

transfer between different DMX devices are used.

 

 

The  connection  arrangement  between  the  devices  has  no  influence  on  the  DMX  addressing.  For 

example, DMX address 1

 

has been assigned to a device, and the DMX connection position can be 

positioned at the beginning, at the end or anywhere in the middle. 

 

Therefore the first device, which is controlled by a controller, can be the last one in a row at the 

same time. When 

the DMX address 1 has been assigned to a device, the DMX controller knows which 

addressers the data send filter, no matter where the DMX cable is located

 

 

Resistance 120 ohms 1 / 4w between PIN 2DMX 

-

) and PIN 3 (DMX +) of the last headlight

 

Attention:

 Avoid the contact between the general and the housing grounding of the headlight. The 

general grounding may cause a loop and your headlight could only function irregularly. Test the 

cables with a resistance meter to check the correct polarity and to ensure the correct polarity. 

 

Connect the headlights: 

 

If you want to control light shows with one or more devices with a DMX

-512 controller, or you want 

to play synchronized shows with two or more devices in master / slave mode, you must use a serial 

data transmission line. The total number of channels required by all devices determines the number 

of devices that the data transmission line can support. 

 

The devices connected to a serial data transmission line must be connected in series. According to 

the standard EIA-

485,  no  more  than  30  devices  should  be  connected  to  a  data  transmission  line. 

However, if you connect more than 30 devices to a serial data transfer line without using an optical 

splitter, the quality of the DMX signal may be degrade

d. 

 

 

 

Maximum recommended length of the DMX data transmission line: 100m

 

 

Maximum  recommended  number  of  headlights  on  a  DMX  data  transmission 

line: 30 devices 

 

With 220V: Up to 6 devices can be connected in series

 

 

 

DMX channel allocation: 

 

8 DMX channels 

Summary of Contents for E60 Spot

Page 1: ...LED Moving Head E60 Spot ...

Page 2: ...LEDs decreases with time The main cause is HEAT because it speeds up the process When LEDs are placed very close together they are exposed to a higher operating temperature than when an ideal distance is maintained or operated under optimal conditions ie individually For this reason the useful life is significantly reduced when all color LEDs are operated with maximum brightness The service life a...

Page 3: ...lly epileptics Intended Use This unit is not suitable for continuous operation Maintaining regular operating breaks increases the life of the unit The minimum distance between the light source and the illuminated area is 0 5 meters The maximum ambient temperature for operation is ta 45 C and must never be exceeded The relative humidity must not exceed 50 at an ambient temperature of 45 C If the ap...

Page 4: ...alifications you should refrain from performing an installation yourself The installation should be inspected once a year by a suitably trained specialist Power connections Connect the device to the power supply with the mains cable Always ensure that the colored cables are connected to the appropriate correct locations International Europe Cable UK Cable USA Cable PIN L BROWN RED YELLOW COPPER PH...

Page 5: ...ears The operator must ensure that all safety related and mechanical devices are inspected once a year by qualified personnel The following points must be considered during the inspection 1 All screws used to install the product or parts of the product must be secured and not corroded 2 Neither the housing nor the fixtures or the places where the product is attached may be deformed 3 Mechanically ...

Page 6: ...omatic correction and functions such as dimmer shutter motorized focus prism and high frequency stroboscopic effects the Moving Head E60 is a versatile device for creative lighting concepts and amazing effects Other features include low overall weight XLR DMX connectors powerCON power sockets and an active cooling system for trouble free operation Technical specifications Power consumption 120W Po...

Page 7: ...erCON IN OUT 5 ON OFF switch 6 Security 7 DMX linking IN OUT Funktionen und Einstellungen LCD Display MENU Function mode selection such as DMX Master Slave Auto Sound Mode and Brightness settings DOWN UP Previous or Next function Enter Confirm and save the selection 1 6 7 2 3 4 5 ...

Page 8: ...S Extended attitude PAN Revers Tilt Revers Display Revers Factory setting starting position password xxx 018 PAN 128 127 Tilt 128 127 Dimmer 128 127 Colour 128 127 Rotation Gobo 128 127 focus 128 127 Mic Empfindlichkeit 000 100 System Info Aktuelle Zeit Gesamtzeit Aktueller Modus Temperatur Software Version E60 V1 06 Manuell Pan 000 255 Tilt 000 255 P T Speed 000 255 Dimmer 000 255 Strobe 000 255 ...

Page 9: ...t The general grounding may cause a loop and your headlight could only function irregularly Test the cables with a resistance meter to check the correct polarity and to ensure the correct polarity Connect the headlights If you want to control light shows with one or more devices with a DMX 512 controller or you want to play synchronized shows with two or more devices in master slave mode you must ...

Page 10: ...ro 3 128 167 Color Gobo macro 4 168 207 Color Gobo macro 5 208 247 Color Gobo macro 6 248 255 Color Gobo changing to music controlled 6 Color gobo speed 000 255 Color Gobo speed from slow to fast 7 Motion macro 000 007 No Function 008 032 Motion macro 1 033 058 Motion macro 2 059 084 Motion macro 3 085 110 Motion macro 4 111 136 Motion macro 5 137 162 Motion macro 6 163 188 Motion macro 7 189 214 ...

Page 11: ...lour4 200 255 Color rotation counter clockwise 077 085 Colour 4 Colour 5 9 Gobo 000 007 Open white 92 112 Gobo5 008 028 Gobo1 113 133 Gobo6 029 049 Gobo2 134 194 Gobo7 050 070 Gobo3 195 255 Gobo Rotation 071 091 Gobo4 10 Gobo Rotation 000 009 No function 010 129 Gobo rotation from fast to slow clockwise 030 134 Gobo rotation stop 135 255 GoboRotation from fast to slow counterclockwise 11 Focus 000...

Page 12: ...______________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _________...

Page 13: ...Page 13 Importeur Hansaring 138 142 48268 Greven Germany Fon 49 0 25 71 80 5 40 42 Fax 49 0 25 71 80 5 40 41 www etec professional de ...

Reviews: