? Can’t power on

   Check whether the adaptor is well plugged and the 5VDC power supply is working.

ERROR CODE AND SOLUTIONS

CODE

PROBLEM

E01

E02

E03

E17

E31

.

34

CO

2

 or PM2.5 sensor is damaged

Measured reading is under the lower limit

Measured reading is above the upper limit

ABC mode of CO

2

 sensor is fail

Temp

./

RH measuring circuit is in error

Send back to repair

For CO

2

 E02: Re-calibrate. For other E02: leave the meter in 

room condition  for 30 mins. 
If it not works, send back to repair

For CO

2

 E03: put the meter in fresh air for 5 mins. For other 

E03: leave the meter in room condition  for 30 mins. 
If it not works, send back to repair

Send back to repair

Send back to repair

SOLUTION

5. Under the stable atmospheric environment, the sudden fluctuation of air humidity would have strong 
    impact to accumulative rise and abrupt rise of PM concentration. 
    The strong fluctuation in RH is an essential condition for 32 times higher of abrupt rise in PM 
    concentration so the probability of abrupt rise in PM2.5 concentration is as high as more than 80% 
    due to the aftereffect of strong RH fluctuation
    Please note, extremely high (ex: 85%) or low RH (35%) could not have big effect on the change in PM 
    concentration but the fluctuation of RH can . This explains why the PM2.5 value abrupt rise while the 
    wheather is suddenly changed. 

 

? Unexpected or expected blackout

   While meter is programmed to record data, once the logging is started, blackout will cause the logging function 
   stop. “StoP”  and real time CO

2

 value will appear in turns. 

   Please return to computer to download data and re-program again.  

? NO response at all 

   The meter might crash after long term usage. There are two methods to power on
   again. One, unplug the power cable for 2 hours and then plug again. If you could 
   not wait for 2 hours time to discharge, please use any suitable and available pin 
   to do the hardware reset. The reset hole is on the rear side of meter, next to PM2.5 
   Air In filter.  Using pin to press the reset key and see the display re-start again.

6.While see the need or after replacing filter, you can manually clean up the PM2.5 sensor periodically. 
    Press “

 

SET

” + “         ” keys at the same time to activate the sensor cleaning function for 10 seconds.

    Please do it in clean environment.  

  

 

II

WARRANTY & RETURN AUTHORIZATION

The meter is warranted to be free from defects in material and workmanship for a period of one year from the 
date of purchase. This warranty covers normal operation and does not cover misuse, abuse, alteration, 
neglect, improper maintenance, or damage resulting from leaking batteries. Proof of purchase is required for 
warranty repairs. Warranty is void if the meter has been opened.

Authorization must be obtained from the supplier before returning items for any reason. When requiring a RA
(Return Authorization), please include data regarding the defective reason, the meters are to be returned along 
with good packing to prevent any damage in delivery and insured against possible damage or loss. 

 

  

 

 

   

 

EASTERN ENERGY CO.,LTD. (HEAD OFFICE)

40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170

Tel: 0-3844-6200   Fax: 0-3844-6205   Email: [email protected]

Contact :

www.ete.co.th

www.ete.co.th

Summary of Contents for 7710

Page 1: ...rant and other public places where personal comfort and healthy are important The standard package contains below CO2 monitor x 1pc USB C cable x 1pc NOTE provided USB C cable is for both data transfer and power charging Operation manual x 1pc Sticker Screws for wall mount hanging dust filter x 1 pack MATERIAL SUPPLIED CAUTION Please take off the AC power adapter when this monitor left idle for lo...

Page 2: ...g 0 1 99 9 RH Humidity o 5 RH at 25 C 10 90 RH o 7 RH at 25 C other range Humidity Response time CO2 Tair Operating Storage Power supply Meter size Weight Standard package 30 seconds 63 step change 2 mins 90 step change o 0 50 C 0 95 RH avoid condensation o 20 50 C 0 95 RH avoid condensation 5VDC USB type C port 610g Meter manual USB type C cable Hanging accessories Power consumption 500mA 20 minu...

Page 3: ...healthy Hazardous 0 0 12 0 12 1 35 4 35 5 55 4 55 5 150 4 150 5 250 4 250 5 350 4 350 5 500 7 Hazardous 5 Setting Long pressing SET key to enter the settings And then press SET key to select setting modes in sequence bL Brightness of light bar ALC 2 0 CO2 Alarm color ALC 3 0 PM2 5 Alarm color Unit temperature unit Buzzer Pressure compensation and ABC auto background calibration Press key to adjust...

Page 4: ... while still connected with computer Windows O S Download memory as csv file to computer csv file could be easily used by many analysis software Within 30 mins Within 30 mins hanging the device in the location where you want to take record Several Days II Press stop key longer time to stop the recording Double click Logger configuration tool to setup the logger The logger configuration screen offe...

Page 5: ...uracy Press SET keys at the same time till CAL and 400 appears Long pressing SET key to start the calibration During the calibration 400 will flash on display After 5 minutes the display return to normal measuring mode to indicate the calibration is done During the calibration procedure long pressing key can quit the calibration function CAUTION Do not calibrate the meter in the air with unknown C...

Page 6: ...oP and real time CO2 value will appear in turns Please return to computer to download data and re program again NO response at all The meter might crash after long term usage There are two methods to power on again One unplug the power cable for 2 hours and then plug again If you could not wait for 2 hours time to discharge please use any suitable and available pin to do the hardware reset The res...

Reviews: