Etdoor 1000E Installation Instructions And User Manual Download Page 10

Installation recommendations

Remember

there are specific standards that have to be strictly followed regarding the safety

rules of electrical installations and automatic gates and doors.
As for the legal requirements and standards that must be adhered to, please take notice of the
following points to ensure maximum safety and reliability of your installation.
1. Before installing, check the surrounding environment. Carefully evaluate any hazards which
could be physical damage (transiting vehicles, parts of trees falling etc.), possible contact with
persons’ bodies (insects, leaves, etc.), flooding hazards, or any other exceptional events.
2.Check the main voltage numbers is the same as the numbers that are given on the rating
plate and in this manual.
3. Check and make sure if there is suitable electrical protection against short circuits/power
spikes and proper earthed on the main supply.

Remember

the unit having main voltage running through it (electrocution hazard, fire

hazard).
4. Take care with the control unit; the parts may be subject to damage if the control unit is
abused.
5. Make sure that you have all the necessary materials, and they are suitable for this kind of
use.
6. Read all the instructions thoroughly, and make sure they are understood before attempting
to install the opener.
7. Before starting the installation carefully analyze all the risks relating to automating the door.
Verify that the door is automated in a sound condition and that the mechanisms are in good
working order. Observe the safety margins and minimum distances.
8. Carefully evaluate the safety devices to be installed and the right place to install them; always
install an emergency stop device for power interruption to the opener if it is required.
9. Once the risks have been analyzed, install the opener and relative safety devices,
emergency stop and/or photoelectric cells.

Important note:

As for additional safety rules, we strongly recommends the fitting of Photo

Electric safety beams on all installations.
10. While installing the opener, strictly follow all the instructions given in the instruction manual.
If some points or procedures in this manual are not very clear, do not install the unit until all
doubts have been cleared up with our technical department.

Summary of Contents for 1000E

Page 1: ...lease read the manual carefully before installation and use The installation of your new door opener must be carried out by a technically qualified or licensed person Attempting to install or repair the door opener without suitable technical qualification may result in severe personal injury death and or property damage ...

Page 2: ... aluminum track 4 Installation steel track 5 Installation sectional steel track 6 Installation recommendations 8 Basic function setting and applying 9 Special function introduction and application 11 Manual disengagement 13 Maintenance 13 Final notes 14 Important information for the user 14 Packing list 14 Technical specifications 15 ...

Page 3: ...rage door is fully closed stationary before leaving 8 Keep hands and loose clothing off the opener and garage door all the time 9 The Safety Obstruction System is designed to work on STATIONARY objects only Serious personal injury death and or property damage may occur if the garage door comes into contact with a moving object 10 This appliance is not intended for use by persons including children...

Page 4: ...verloading force detecting the door will reverse more than 15 cm automatically when it is overloaded when closing and will stop when it is overloaded when opening 4 Safety resistance adjustable with a wide range sensitive and reliable 5 Low voltage protection the process will not perform any action of opening and closing when voltage is too low door panel and controller won t be damaged 6 We adopt...

Page 5: ...4V DC flash light optional 6 Power socket 3 Wall switch optional 7 Door opener 4 Photo beam optional Maintain a minimum gap of 30mm from the top panel s maximum height Fig 2 Make sure the track is horizontal and vertical to the shaft Make sure the connection of hanging bracket F and ceiling is firm enough Fig 3 Warning Make sure the opener is affixed to noggins in ceiling and not to plasterboard F...

Page 6: ...m in place using a second 6mm nut and then lock the brackets to the rail by tightening the inverted lock nuts D Connect the opener edge G to the hanging bracket F Connect the aluminum track to the wall bracket Fig 5 Check measurements for drilling insert and lock the brackets F and fix the opener to the ceiling with the correct fixings Fig 3 Cut off any hanging brackets excess Fig 4 Fig 5 ...

Page 7: ...xing the opener on ceiling by hanging bracket Notice Make sure the track is horizontal and vertical to the shaft Make sure the connection of hanging bracket and ceiling is firm enough 5 Fix the clutch cord 6 Release the clutch try to open and close the door by hand Make sure there is no resistance between door panel and track 7 Connecting the opener with power and adjusting the operation Notice Ma...

Page 8: ...Installation sectional steel track Fig 7 Fig 8 Fig 9 The middle rail The first sleeve The end rail The top rail The second sleeve The middle rail The first sleeve The end rail A A ...

Page 9: ...slide the top rail into the 2nd sleeve 3 Remove the plastic film on the end rail cut the plastic cable tie on the screw rod A 4 As Fig 9 pull the screw rod A along with inner chain to the end of top rail 5 As Fig 10 undo the nut spring 6 Tight the nut to the right position as shown in Fig 11 cut the plastic cable tie on sprocket then whole rail assembled finished B 19MM ...

Page 10: ...ay be subject to damage if the control unit is abused 5 Make sure that you have all the necessary materials and they are suitable for this kind of use 6 Read all the instructions thoroughly and make sure they are understood before attempting to install the opener 7 Before starting the installation carefully analyze all the risks relating to automating the door Verify that the door is automated in ...

Page 11: ... limit position then press set button The opener will operate a cycle automatically to remember the limit positions and the opening closing force Press CODE button and hold on until the LED dot is on Fig A Then press any button on the transmitter once the dot will be off press the button again the dot will fast flash then LED displays 11 Fig B After that the transmitter will be available Press COD...

Page 12: ...DOWN button and hold on until the LED displays 11 press UP button the LED displays H photo beam function is available Press DOWN button the LED displays 11 to cancel this function When setting is finished press SET to confirm When connecting pulsed quantity control infrared sensor wiring as Fig 12 When infrared sensor is controlled by switch value wiring as Fig 13 Notice Close the photo beam funct...

Page 13: ... photo beam function when you don t use photo beam sensor 3 Flash light function optional There are corresponding interfaces for this function and provide 24v 35v flash light voltage Connect the flash light with DC 24v 28v current 100mA When use AC 220V power flash lights please match an adapter and wiring as required Fig 14 4 Pass door SD protection optional This function ensures that the door ca...

Page 14: ...Fig 14 Fig 15 ...

Page 15: ...te it is recommended that an external disengagement device should be fitted Fig 17 Maintenance No particular maintenance is required for the logic circuit board Check the door at least twice a year if it is properly balanced and all working parts are in good working condition or not Check the reversing sensitivity at least twice a year and adjust if it is necessary Make sure that the safety device...

Page 16: ...s and all the risks that can arise if it is used improperly The user must avoid placing himself herself in dangerous situations such as standing within the door s operating range when it is moving Do not let children play near the door and keep the remote controls out of their reach All services repairs or checks must be carried out by professionally qualified persons and noted on a maintenance re...

Page 17: ...DC LED 24V DC LED 24V DC Light time 3 minutes 3 minutes 3 minutes Decoding Rolling code Rolling code Rolling code Transmitter power 23A 12V battery 23A 12V battery 23A 12V battery Radio frequency 433 92MHz or other on request 433 92MHz or other on request 433 92MHz or other on request Working temperature 20 40 20 40 20 40 Relative humidity 90 90 90 Max door area 10m2 12m2 14m2 Dimensions 400 x 250...

Reviews: