ETCR 6000 Manual Download Page 3

 

-2- 

Warning 

 

Thank you for purchasing our company's 

ETCR6000 AC/DC Clamp Leaker

, for better use of this 

product, please: 

——

Read carefully the user's manual.   

——

Follow strictly safety rules and notes listed in this manual.   

 

u

    Under any circumstances, please pay special attention to your safety in the course of using this 

leaker. 

u

    Give heed to label texts and symbols on panel and back plate of this leaker. 

u

    Please be more careful if the line voltage is above 60VDC or 30VAC. 

u

    After power on, please first calibrate zero before measuring.   

u

    Put the tested wire through the geometrical center of jaw when measuring AC current, error will 

increase if deviate the center. 

u

    Please  don't  place  and  store  this  leaker  in  hot  and  humid  condition,  locations  with  moisture 

condensation and under direct sunlight for a long time. 

u

    In case voltage of battery was low, please replace batteries. 

u

    In case this leaker would not be used for a long time, please take out batteries.   

u

    When changing batteries, please pay attention to polarity of battery.   

u

    Use, disassembly and maintenance of this leaker shall be operated by authorized personnel. 

u

    In case dangers would have with continues use of this leaker, please stop to use it and seal it for 

safekeeping immediately; and then, send it for disposal of authorized agency.   

u

    Users shall carry out operation based on danger signs 

       

 on leaker and manual.   

u

    Users shall carry out safety operation based on instructions listed in this manual, e.g. 

       

 and 

danger signs on this manual.   

 
 

I Introduction   

ETCR6000  AC/DC  Clamp  Leaker

  is  specially  designed  for  measurement  of  AC/DC  current;  by 

adopting up-to-date CT technology and digital integration technology. The small clamp is suitable for line 

densely places (electric power measurement system, the high speed rail system, car circuit overhaul, 

and so on), non-contact measurement, to ensure safe operation. It is a product with relatively small size, 

high  accuracy  and  perfect  function  compared  with  similar  leakers  in  the  world.  The  leaker  could  be 

widely applied in those fields as electricity, communications, meteorology, railroad, oilfield, construction, 

measurement,  scientific  &  research  teaching  institutes,  industrial  and  mining  establishments.  it  is  an 

essential tool for electrician safety testing. 

ETCR6000  AC/DC  Clamp  Leaker 

also  named: 

DC  Leakage  Current  Clamp  Meter

Car

 

DC 

Leakage Current Clamp Meter

,

 AC/DC Clamp Leakage Current Tester

. It has those functions as data 

holding and data storage. It obtains one RS232 interface, communication cable and software, through 

which historical data inquiry is available, for reading, saving and printing. 

 

 

 

Summary of Contents for 6000

Page 1: ......

Page 2: ...I Electrical Signs 3 Ⅲ Technical Specifications 3 Ⅳ Structure 4 Ⅴ LCD Display 4 Ⅵ Operating Method 4 1 Start up Shutdown 4 2 Calibration 4 4 Hold Storage Access Reading and Deleting 5 5 Data Upload 5 Ⅶ How to Change Battery 6 Ⅷ Accessories 6 ...

Page 3: ...e it and seal it for safekeeping immediately and then send it for disposal of authorized agency u Users shall carry out operation based on danger signs on leaker and manual u Users shall carry out safety operation based on instructions listed in this manual e g and danger signs on this manual I Introduction ETCR6000 AC DC Clamp Leaker is specially designed for measurement of AC DC current by adopt...

Page 4: ...ng Rate 2 times s Frequency AC 45Hz 400Hz Polarity Indication DC current auto identified and display Test Position Tested wire in the jaw center Range Shift Automatically Line Voltage AC600V RS232 Interface Data stored in the memory of the meter via RS232 upload to PC Com Configure Baud rate 9600 data bit 8 stop bit 1 Data Memory 99units FULL blinks when the memory is full Reading Hold DH indicati...

Page 5: ...the leaker will shut down automatically after flickering for 30s it will shut down formally to reduce battery consumption In case you have pressed HOLD key when LCD was flickering the leaker will continue to work for 5 minutes If the tester power off automatically the gear should firstly be switched to OFF for power on next time 2 Calibration When measuring first choose AC or DC gear adjust ZERO k...

Page 6: ...a and automatically stored in the memory with a code press HOLD key again to release the hold state and the leaker continues its measuring in case stored data reached to 60 groups press HOLD key again the FULL symbol will display which means storage memory is full press HOLD key to cancel FULL flickering and return to measuring mode 2 Long press HOLD key to enter into data access mode and display ...

Page 7: ...t off the battery to storage 1 symbol means the battery is undercharge and need to be replaced 2 Shut down the leaker before opening the battery cover please confirm the leaker is in off position and then replace with qualified new battery special attention shall be paid to polarity of battery at last cover battery cover plate Ⅷ Accessories Clamp tester 1 pc RS232 Com cable 1 pc Software 1 disk Ba...

Page 8: ...CR Electronic Technology Company Address F 3F No 4 Pengshang Zhifu Road Jiahe Baiyun District Guangzhou Guangdong China Post Code 510440 Tel 86 20 62199556 62199553 Fax 86 20 62199550 E mail info etcr cc Website www etcr cc ...

Reviews: