Fixture information

HPL lamp table

CAUTION: Do not use lamps other than the HPL in Source Four 

fixtures. Use of lamps other than HPL will void UL/cUL 
safety compliance and your warranty.

Lamp code

Watts Volts

Initial 

Lumen

Color 

temp.

Average 

rated life

HPL 780/77*

750

77

22,950

3,250°

300 hours

HPL 550/77*

550

77

16,170

3,250°

300 hours

HPL 550/77X*

550

77

12,160

3,050°

2000 hours

HPL 750/115

750

115

21,900

3,250°K

300 hours

HPL 750/115X

750

115

16,400

3,050°

1500 hours

HPL 575/115

575

115

16,520

3,250°K

300 hours

HPL 575/115X

575

115

12,360

3,050°K

2000 hours

HPL 375/115

375

115

10,540

3,250°K

300 hours

HPL 375/115X

375

115

8,000

3,050°K

1000 hours

HPL 750/120

750

120

21,900

3,250°K

300 hours

HPL 750/120X

750

130

16,400

3,0500°K

1500 hours

HPL 575/120

575

120

16,520

3,250°K

300 hours

HPL 575/120X

575

120

12,360

3,050°K

2000 hours

HPL 750/230

750

230

19,750

3,200°K

300 hours

HPL 750/230X

750

230

15,600

3,050°K

1500 hours

HPL 575/230

575

230

14,900

3,200°K

400 hours

HPL 575/230X

575

230

11,780

3,050°K

1500 hours

HPL 375/230X

375

230

7,250

3,000°K

1000 hours

HPL 750/240

750

240

19,750

3,200°K

300 hours

HPL 750/240X

750

240

15,600

3,050°K

1500 hours

HPL 575/240

575

240

14,900

3,050°K

400 hours

HPL 575/240X

575

240

11,780

3,050°K

1500 hours

HPL 375/240X

375

240

7,250

3,000°K

1000 hours

* To be used with ETC Dimmer Doubler™

Summary of Contents for Source Four PARNel

Page 1: ...c Theatre Controls Inc Product information and specifications subject to change ETC intends this document to be provided in its entirety 7061M1008 Rev E Released 2016 11 Production dates September 200...

Page 2: ...5 12 360 3 050 K 2000 hours HPL 375 115 375 115 10 540 3 250 K 300 hours HPL 375 115X 375 115 8 000 3 050 K 1000 hours HPL 750 120 750 120 21 900 3 250 K 300 hours HPL 750 120X 750 130 16 400 3 0500 K...

Page 3: ...hanging the fixture Note Use only color frames or accessories with 7 5 inch mounting flange Note The performance of saturated colors may be less than desirable in any theatrical lighting fixture espe...

Page 4: ...available See HPL lamp table on page 2 Operating HPL lamps above their rated voltage reduces lamp life and can cause premature lamp failure WARNING Unplug the fixture and allow it to cool down before...

Page 5: ...ss lamp retaining clip across lamp base to secure 7 Reinstall the lamp housing by aligning the bolt hole and tightening the knurled bolt Focus knob positioning To adjust focus knob tension loosen or t...

Page 6: ...emove or install lenses with fixture hanging 2 Rotate the focus knob to the full spot position 3 Tilt the front of the fixture down at least 45 See figure below 4 Press the spring clip with your finge...

Page 7: ...ns rotator ring 5 Gently push the top of the lens inward until it snaps behind the spring clip Positioning the wave stippled front lens 1 There are seven notches cut into the stippled side of the lens...

Page 8: ...ctor The reflector is located behind the rear fixed position wave clear lens and requires disassembly of the fixture to access it See the Source Four PARNel Assembly Guide for instructions on fixture...

Reviews: