14
Source 4WRD II Installation and User Manual
Configure the Fixture
Up and down
navigation buttons
User interface
The two-button, seven-segment display
shows the DMX address, AC mode, or
the manually-set level. Use the up and
down navigation buttons to configure
the fixture.
•
Set a DMX address: Use the up and
down arrows to navigate to
the desired DMX address number
(1–512).
•
Set the fixture to use line-dimming
(AC mode): Use the down arrow to
navigate one number below DMX
address 1. The display will read
AC
.
•
Manually set a level: Use the down arrow to navigate one number
below
AC
. The display will read
L.FL
(Level = Full). Use the down
arrow to decrease the level to a percentage of full (
L.99
= 99%,
L.98
= 98%, etc.). You can set levels from 0%–100% (full).
RDM Values
Parameter
RDM PID
Value
Manufacturer ID
0x6574
Electronic Theatre Controls
Model ID
0x0801
ETC Source 4WRD II (230 V)
DMX Start Address
0x00F0
Range = 1–512
Personality ID
0x00E0
1 = DMX
2 = AC Dimming
3 = Local Control