Irideon Control Installation and User Manual
25
Composer Lite
Purpose and Function:
A Composer Lite system requires that a custom sequence with up to 30
presets, programmed via Composer Lite Software, be downloaded from
the PC to the luminaire(s) and stored in the luminaire memory. Once the
programmed sequence is downloaded to the luminaire, it can be played
from a master luminaire (luminaire #1) by toggling the luminaire address
into test mode (address 0 for the AR50 and AR500, for the AR6 turn dip
switch #7 ON). Once the luminaires have the sequence, there is no need
to have a PC to control the luminaires, unless a change in sequence is
desired.
The Composer Lite Control System configuration utilizes an RJ45
connection from the PC to the luminaires or Luminaire Programming Jack
for programming. This system is limited to 1-31 Irideon luminaires which
are to be wired in a single data run (daisy chain configuration). Remote
Control Stations are not compatible.
AC
AC
AC
AR6's
AR50's
AR500's
Standard & Remote
Luminaire Data
LPJ
CL/PK
Summary of Contents for IRIDEON
Page 10: ...6 Introduction This page intentionally blank...
Page 44: ...40 System Test This page intentionally blank...
Page 50: ...46 Troubleshooting This page intentionally blank...
Page 60: ...56 Maintenance This page intentionally blank...
Page 64: ...60 Software Hardware Components This page intentionally blank...
Page 70: ...66 Astronomical Time Clock installation instructions This page intentionally blank...
Page 83: ...Irideon Control Installation and User Manual 79 This page intentionally blank...