20
Irideon WLZ User Manual
RDM Values
Parameter
RDM PID
Value
Manufacturer ID
0x6574
Electronic Theatre Controls
Model ID
0x901
Irideon WLZ
DMX Start Address
0x00F0
Range = 1–512
Personality ID
0x00E0
1=DMX
2=Local
Output Frequency
0x8123
0 = Standard (1.2 kHz)
1 = High (25 kHz)
Focus and Setup
Yoke
locking
knob
Adjust the Tilt
1. Loosen, but do not remove the
yoke locking knob.
2. Tilt the fixture to the desired
angle.
3. Tighten the yoke locking knob.
Field angle
markers
Adjust the Field
Rotate the back of the fixture body to adjust the
field between wide and narrow (see image at
left). The field angle markers on the side of the
fixture indicate the field angle as you adjust
within the range of 16–91 degrees.