background image

13

14

(diagram 17)

Under normal working condition, hold down POWER knob at the left of panel, 
at the same time long press (>5s) the UP knob or DOWN or SET to adjust 
temperature to the required values separately in term1 or term2 or term3. 
When you hold down POWER knob at the left of panel and short press (<5s) UP
or DOWN or SET knob to use the storage setting temperature into current work
temperature and air volume.

(Notice: up, down, set refer to storage term1, term2, term3)

3.Shortcut keys set storage 

Under normal working condition, hold down both POWER knob at right of 
panel and " 

" knob on the handle to calibrate soldering station temperature 

(diagram18). Temperature value can be calibrated by pressing UP or DOWN
knobs. Pressing the SET knob to confirm storage and quit from this calibration 
(diagram 11).

4.Temperature comp temperature and calibration

(diagram 18)

In normal working condition, press POWER key at the right of panel to make
the device be standby (diagram 2). Make the power off, at the same time, the
soldering station is off and the whole station will off when the temperature is
low to 100 .

5.Standby 

Standby state of screen B

(diagram 2)

A. When "H-E"  is displayed on the screen A, there is no temperature  
     (diagram19),which indicates that the heating element fails.
B. When "S-E"  is displayed on the screen A, there is a fault in sensor
     (diagram20), which signifies that there is something wrong with 
     the sensor or the related circuit of the sensor. 

6.Error/Fault indication

Screen B: fault of heating

screen B: fault of sensor 

(diagram 19)

(diagram 20)

III. Conversion of temperature unit

Under the power off condition, hold down the UP, DOWN and SET knob and 
then put power on to switch 

/

.

IV. Replacement of heater

Please follow the following steps for the successful replacement of the heating
element of hot-air rework station:

A. Cut down power, please refer to the following diagram to replace heater
     after it is cool.
B. Based on diagram, loosen the three screws of the handle.
C. Dismantle the upper cover of the handle, pull out the ground wire on the
     duct and take out the fan.
D. Take out the heating element from PCB board.

Summary of Contents for ETC-RW900D

Page 1: ...User s Manual SOLDERING STATION SMD REWOEK ETC RW900D Intelligent lead free rework station CBN 019006 2 in 1 THERMO CONTROL ANTI STATIC...

Page 2: ...of the nozzles which is normal 9 Don t touch the iron tip or surrounding metals 10 Change the components or tip after cutting off power and waiting to cool it 11 Don t use this device do other work e...

Page 3: ...old air delay shutdown power off A screen to display working station of soldering stations power switch 12 12 Button instructions Position Knob Button First function Second function short press 5s Sec...

Page 4: ...erature area 2 which means thedevice is standby When the temperature area shines the station isunder the condition available to set Description for LCD display Upon power on the unit the reworking sta...

Page 5: ...perature 4s no press or press SET knob you can keep the temperature and quit out this setting diagram 7 B Setting hot airvolume via handleof rework station You can pressUP knob or DOWN knob to adjust...

Page 6: ...off after the temperature below 100 9 Standby diagram 1A diagram 1 Standby state of screen A 1 When H E is displayed onthe screen A there is nohot air inthe nozzle diagram13 which indicatesthat the he...

Page 7: ...iagram 2 Make the power off at the same time the soldering station isoff and thewhole station willoff when thetemperature is low to 100 5 Standby Standby state of screen B diagram 2 A When H E is disp...

Page 8: ...uartz tube PCB Top shell Lower shell ETC RW900D Power cord Nozzle Bracket handle iron holder User manual 1 unit 1 strip 1 set 1 set 1 pc 1 set 1 copy WARNING This tool be placed on its stand when not...

Page 9: ...17 18 Interchangeable soldering tips of soldering station Nozzles...