background image

9

10

Under the setting condition. Then you can press "SET" button to set hot
-air rework station' s temperature and the main temperature area shines
the setting temperature, you can press UP knob or DOWN knob to adjust
the setting temperature. 4s-no-press or press SET knob, you can keep the
temperature and quit out this setting. (Diagram 6).

A. Setting temperature via handle of rework station. You can press UP knob
    or DOWN knob directly to adjust temperature and the main temperature
    area indicators setting temperature. 4s-no-press or press SET knob, you 
    can keep the temperature and quit out this setting, at that time, you can
    adjust hot-air volume by pressing " " Whether screen A or screen B 
    shine 

 as you set, the device is under the setting condition and 

    shining area for 

  switch to screen "A " automatically.

Notice: 

continually pressing UP or DOWN knob in long time will quickly adjust 

the temperature, at that time, the screen don't shine. 

(Same as below description)

    

In normal working condition, there are two methods to set hot-air volume:

A. If screen A shines 

 setting temperature through operating the 

    button of panel. If screen A doesn't shine 

 you must press the "SET"

    button to switch to shine  

 of screen A then the station under the 

    setting condition. Then you can press "SET" button to set hot-air rework
    station' s temperature and the main temperature area shines the setting 
    temperature, you can press UP knob or DOWN knob to adjust the setting 
    temperature. 4s-no-press or press SET knob, you can keep the 
    temperature and quit out this setting (diagram 7). 

B. Setting hot-air volume via handle of rework station. You can press UP 
    knob or DOWN knob to adjust hot-air volume and the main temperature
    area indicators setting volume. 4s-no-press or press SET knob, you can
    keep the volume and quit out this setting, at that time, you can adjust
    hot-air volume by pressing "

" When the screen A or screen B shine 

    

 as you set, the device is under the setting condition and shining 

    area for 

 switch to screen"A" automatically. 

4.Hot-air volume settings

5. Storing the Temperature values

Under normal working condition, hold down POWER knob at the left of panel, 
at the same time long press (>5s) the UP knob or DOWN or SET to adjust 
temperature and air volume to the required values separately in term 1 or 
term 2 or term 3. But when you hold down POWER knob at the left of panel and
short press (<5s) UP or DOWN or SET knob to use the storage setting 
temperature and air volume into current work temperature and air volume
(diagram8, diagram9, diagram10).  
(Notice: up, down, set refer to storage term 1, term 2, term 3)

(diagram 6)

(diagram 7)

(diagram 8)

(diagram 9)

(diagram 10)

Screen A: 

Working state of shortcut 1 

Screen A: 

Working state of shortcut 2

Screen A: 

Working state of shortcut 3

6.Temperature comp temperature and calibration
    

     Under normal working condition, hold down both POWER knob at left of 
     panel and  "

" knob on the handle to calibrate.  Screen A will display the 

     character CAL, and temperature value can be calibrated by pressing UP or 
     DOWN knobs. Pressing the SET knob to confirm storage and quit from this 
     calibration (diagram 11).  

Summary of Contents for ETC-RW900D

Page 1: ...User s Manual SOLDERING STATION SMD REWOEK ETC RW900D Intelligent lead free rework station CBN 019006 2 in 1 THERMO CONTROL ANTI STATIC...

Page 2: ...of the nozzles which is normal 9 Don t touch the iron tip or surrounding metals 10 Change the components or tip after cutting off power and waiting to cool it 11 Don t use this device do other work e...

Page 3: ...old air delay shutdown power off A screen to display working station of soldering stations power switch 12 12 Button instructions Position Knob Button First function Second function short press 5s Sec...

Page 4: ...erature area 2 which means thedevice is standby When the temperature area shines the station isunder the condition available to set Description for LCD display Upon power on the unit the reworking sta...

Page 5: ...perature 4s no press or press SET knob you can keep the temperature and quit out this setting diagram 7 B Setting hot airvolume via handleof rework station You can pressUP knob or DOWN knob to adjust...

Page 6: ...off after the temperature below 100 9 Standby diagram 1A diagram 1 Standby state of screen A 1 When H E is displayed onthe screen A there is nohot air inthe nozzle diagram13 which indicatesthat the he...

Page 7: ...iagram 2 Make the power off at the same time the soldering station isoff and thewhole station willoff when thetemperature is low to 100 5 Standby Standby state of screen B diagram 2 A When H E is disp...

Page 8: ...uartz tube PCB Top shell Lower shell ETC RW900D Power cord Nozzle Bracket handle iron holder User manual 1 unit 1 strip 1 set 1 set 1 pc 1 set 1 copy WARNING This tool be placed on its stand when not...

Page 9: ...17 18 Interchangeable soldering tips of soldering station Nozzles...