Custom

The 1-button station provides the following button actions by default before configuration using
ElahoAccess:

Push

Hold

Double-tap

Double-tap the button to toggle the zone to its full or off, using a 1/2 second fade time.

Note:

These are the default button actions for the station when the Function switch is

set to Custom. For custom configuration using ElahoAccess, reference the ElahoAccess
Mobile App integrated help system.

Summary of Contents for Echoflex Elaho Inspire Station

Page 1: ...Part Number 8186M1220 3 1 0 Rev A Released 2018 09 Elaho Inspire Stations Programming Guide Echo Protocol Version 3 1 ...

Page 2: ...ronic Theatre Controls Inc in the United States and other countries All other trademarks both marked and not marked are the property of their respective owners Echoflex intends this document whether printed or electronic to be provided in its entirety ...

Page 3: ...5 Preset Mode Raise Lower 5 Sequence Control 5 Function switch Custom 5 With ElahoAccess 5 Without ElahoAccess 6 Function switch Zone 6 Zone Selection 6 Zone Toggle 6 Space Toggle 4 button with fader station only 6 Zone Raise Lower 7 Color Control Mode 4 button with fader station only 8 Record Program Mode 10 Program Preset Start 10 Record Preset 10 Program Zone Start 11 Space Combine 4 button onl...

Page 4: ...ry Defaults 21 Preset 21 Zone 22 Custom 23 Space Combine in Preset 23 Space Combine in Zone 24 Space Combine in Custom 25 4 Button with Fader Station 26 Factory Defaults 26 Preset 26 Zone 27 Zone with Color Control Enabled 28 Custom 30 6 Button Station 31 Factory Defaults 31 Preset 31 Zone 32 Custom 33 8 Button Station 34 Factory Defaults 34 Preset 34 Zone 35 Custom 36 Station Miscellaneous 37 Rem...

Page 5: ...emove Wall Plate 38 Install Wall Plate 38 Install Button Legends 39 Rotary Switch Assignments 40 DIP Switch Settings 40 4 Button with Fader Station Color Mode DIP Switch Settings 41 Table of Contents iii ...

Page 6: ...ion using ElahoAccess reference the ElahoAccess Mobile App integrated help system Document Conventions This document uses the following convention to draw your attention to important information Note Notes are helpful hints and information that is supplemental to the main text Echoflex s user documents are designed for printed or electronic use However there are many advantages to using the electr...

Page 7: ...sources are sufficient contact Echoflex Technical Services directly at one of the offices identified below When calling for help take these steps first Prepare a detailed description of the problem Go near the equipment for troubleshooting Find your notification number if you have called in previously Echoflex 38924 Queensway Unit 1 Squamish British Columbia Canada V8B 0K8 888 324 6359 toll free 1...

Page 8: ...station type and its possible function settings or download the Inspire Station data sheet located on the Echoflex website echoflexsolutions com for the complete listing including model and ordering information This programming guide is provided to detail the basic functions of the Inspire stations For more detailed information about the custom configuration options using ElahoAccess reference the...

Page 9: ...d information regarding these switches and settings Function switch Preset Setting the Function switch to Preset the highest switch setting on an Inspire Station allows you to perform preset related actions such as preset toggle Off record snapshot levels space raise lower and sequence control 1 button station only Preset Toggle Preset toggle control functionality allows you to toggle the preset o...

Page 10: ...the 1 button station in conjunction with Echoflex power control products that support sequences DIP switch 1 must be set to the On position to enable sequence mode For more information DIP Switch Settings on page 40 In sequence mode pressing the station button will toggle the sequence for the selected space i e activate the sequence if it is inactive or deactivate it if it is active Reference the ...

Page 11: ...h is set to Zone the station provides visual indication of its current zone selection with backlit button LEDs When a zone is un selected the associated button will have no LED indication To select a zone push the Zone button The button will illuminate in blue to indicate selection Once a zone is selected raise lower functionality for only that zone is possible Reference Zone Raise Lower for more ...

Page 12: ...ntensity level for all zones in the space Push and hold the raise or lower button to fade the level gradually altering the intensity level for all zones in the space A double tap of the raise or lower button toggles the intensity level to full or off for all zones in the space using a 1 2 second fade Zone Raise Lower from a Fader 4 button with fader station only With a Zone Selected With a zone se...

Page 13: ...he next mode in a repeating fashion Modes are intensity saturation and hue Intensity When the fader knob is controlling intensity the 6 o clock amber dot will be lit As the intensity increases or decreases the fader knob halo indicates intensity level A clockwise rotation of the fader increases zone intensity A counter clockwise rotation decreases zone intensity Saturation Saturation mode has a 0 ...

Page 14: ...ugh three modes where each push selects the next mode in a repeating fashion Modes are intensity color temperature and tint Intensity When the fader knob is controlling intensity the 6 o clock amber dot will be lit As the intensity increases or decreases the fader knob halo indicates intensity level A clockwise rotation of the fader increases zone intensity A counter clockwise rotation decreases z...

Page 15: ...d is preset 3 the button LED will flash 3 times 3 Push any station button to increase the starting preset number by one the count always begins at 1 The station will update the LED indication flashing the LED to reflect the new preset number For example pushing the station button eight times will set the first preset for the station to preset 8 All station preset controls will be consecutively ass...

Page 16: ...station will update the LED indication flashing the LED to reflect the new zone number For example pushing the station button three times will set the first zone for the station to zone 3 All station zone controls will be consecutively assigned beginning with the specified count 4 When the desired zone number is set press and release the Record Program mode button to save the new setting The Mode ...

Page 17: ...ctionality changes as the room configurations change The spaces that combine are determined by the function of the station either Preset or Zone control Note Before space combine functionality is possible your connected system must have all of the spaces configured that you want to combine In the example above the system must be configured with four spaces in order to effectively combine their con...

Page 18: ...bined space pair for the station to Spaces 8 and 9 All station combined space pairs will be consecutively assigned to the controls beginning with the specified count 3 When the desired space combine pair is set press and release the Record Program mode button to save the new setting The Mode LED turns off and the station LEDs will display the new setting before returning to normal operation Note T...

Page 19: ...uding its factory default settings and each button default when the station function switch is set to Preset Custom and Zone 1 Button Station on the next page 2 Button Station on page 18 4 Button Station on page 21 4 Button with Fader Station on page 26 6 Button Station on page 31 8 Button Station on page 34 ...

Page 20: ...witch Settings on page 40 With the Function switch set to Preset Preset 1 is the default With the Function switch set to Zone Zone 1 is the default Preset The 1 button station supports the following button actions Push Note When DIP switch 1 is On and the station Function switch is set to Preset Sequence toggle mode is enabled available on the 1 button station only This feature allows the button t...

Page 21: ...Station Functionality 16 Zone The 1 button station supports the following button actions Push Hold Double tap Double tap the button to toggle the zone to its full or off using a 1 2 second fade time ...

Page 22: ...ation using ElahoAccess Push Hold Double tap Double tap the button to toggle the zone to its full or off using a 1 2 second fade time Note These are the default button actions for the station when the Function switch is set to Custom For custom configuration using ElahoAccess reference the ElahoAccess Mobile App integrated help system ...

Page 23: ...Off functionality All others are set to Off Reference DIP Switch Settings on page 40 With the Function switch set to Preset Preset 1 is the default starting preset With the Function switch set to Zone Zone 1 is the default starting zone Preset The 2 button station supports the following button actions Push Hold Double tap Double tap the button to toggle the preset using a 1 2 second fade time Note...

Page 24: ... supports the following button actions Push Hold Double tap Double tap the button to toggle the zone to its extents using a 1 2 second fade time Custom The 2 button station provides the following button actions by default before configuration using ElahoAccess Push Hold ...

Page 25: ...toggle the zone to its extents using a 1 2 second fade time Note These are the default button actions for the station when the Function switch is set to Custom For custom configuration using ElahoAccess reference the ElahoAccess Mobile App integrated help system ...

Page 26: ...ult settings Rotary switches are set to Address 1 Space 1 Reference Rotary Switch Assignments on page 40 DIP switch 1 is set to On for Use Off functionality All others are set to Off Reference DIP Switch Settings on page 40 With the Function switch set to Preset Preset 1 is the default starting preset With the Function switch set to Zone Zone one 1 is the default starting zone Preset The 4 button ...

Page 27: ...ts extents using a 1 2 second fade time With No Zone Selected When no zone is selected the raise selection and lower selection buttons 1 and 4 change the intensity levels for the configured space A double tap on the raise selection or lower selection buttons 1 and 4 changes the levels for the configured spsace to their extents using a 1 2 second fade time ...

Page 28: ... second fade time Note These are the default button actions for the 4 button station when the Function switch is set to Custom For custom configuration using ElahoAccess reference the ElahoAccess Mobile App integrated help system Space Combine in Preset Setting the Function switch to Preset with DIP switch 3 On enables space combine mode on the 4 button station The 4 button station in Space Combin...

Page 29: ...e with the first space configured for control on the station All combine actions are toggles essentially wall toggles that both combine and un combine the specified spaces Space Combine in Zone Setting the Function switch to Zone with DIP switch 3 On enables Space Combine mode on the 4 button station The 4 button station in Space Combine mode supports the following button actions Push Hold Note Do...

Page 30: ...n in Space Combine mode supports the following button actions by default before configuration using ElahoAccess Push Hold Note Double tap is not a supported feature in Space Combine mode Note These are the default button actions for the 4 button station when the Function switch is set to Custom For custom configuration using ElahoAccess reference the ElahoAccess Mobile App integrated help system ...

Page 31: ...ings on page 40 With the Function switch set to Preset the fader knob is Preset 1 With the Function switch set to Zone Zone 1 is the starting zone Preset The 4 button with fader station supports the following button actions Push Note Hold is not a supported feature in Preset mode Double tap Double tap the button to toggle the preset using a 1 2 second fade time Note When DIP switch 1 is set to On ...

Page 32: ...second fade time Push the fader knob to execute an Off command anytime presets or zones are On in the same space otherwise the action toggles the space With No Zone Selected When no zone is selected rotate the fader knob to perform a space raise lower changing all zone levels for the configured space Double tap on the fader knob to change the zone levels for the configured space to their extents u...

Page 33: ...Enabled With the Function switch set to Zone and with Color Control mode enabled by configuring DIP switches 5 and 6 the 4 button with fader station supports the following fader actions HSI Color Mode Intensity Saturation Hue Color Temp Mode Intensity ...

Page 34: ...tion Programming Guide Color Temp Studio Mode Intensity Color Temp Tint With No Zone Selected When no zone is selected rotate the fader knob to perform space wide commands changing all zone levels for the configured space ...

Page 35: ...the button or fader knob to toggle the zone or space using a 1 2 second fade time Push the fader knob to execute an Off command anytime presets or zones are On in the same space otherwise the action toggles the space Note These are the default button and fader actions for Custom control mode For custom configuration using ElahoAccess reference the ElahoAccess Mobile App integrated help system ...

Page 36: ...witch 1 is set to On for Use Off functionality All others are set to Off Reference DIP Switch Settings on page 40 With the Function switch set to Preset Preset 1 is the default starting preset With the Function switch set to Zone Zone 1 is the default starting zone Preset The 6 button station supports the following button actions Push Hold Double tap Double tap the button to toggle the preset usin...

Page 37: ...ed zone or space using a 1 2 second fade time With No Zone Selected When no zone is selected the raise and lower buttons 1 and 6 perform a space raise and space lower changing all zone levels for the configured space A double tap on the raise or lower button changes the zone levels for the configured space to their extents using a 1 2 second fade time ...

Page 38: ...ration using ElahoAccess Push Hold Double tap Double tap the button to toggle the selected zone or space using a 1 2 second fade time Note These are the default button actions for the station when the Function switch is set to Custom For custom configuration using ElahoAccess reference the ElahoAccess Mobile App integrated help system ...

Page 39: ... All DIP switches are set to Off Reference DIP Switch Settings on page 40 With the Function switch set to Preset Preset 1 is the default starting preset With the Function switch set to Zone Zone 1 raise is the default starting zone Preset The 8 button station supports the following button actions Push Hold Double tap Double tap the button to toggle the preset using a 1 2 second fade time Note When...

Page 40: ... the selected zone or space using a 1 2 second fade time With No Zone Selected When no zone is selected the raise and lower buttons 7 8 perform a space raise and space lower changing all zone levels for the configured space A double tap on the raise or lower button changes the zone levels for the configured space to their extents using a 1 2 second fade time ...

Page 41: ...ing ElahoAccess Push Hold Double tap Double tap the button to toggle the selected zone or space using a 1 2 second fade time Note These are the default button actions for the station when the Function switch is set to Custom For custom configuration using ElahoAccess reference the ElahoAccess Mobile App integrated help system ...

Page 42: ...s section provides information pertaining to the mechanical features of the Inspire Stations including the following Remove or Install the Wall Plate on the facing page Install Button Legends on page 39 Rotary Switch Assignments on page 40 DIP Switch Settings on page 40 ...

Page 43: ...tabs on the top of the station electronics assembly Install Wall Plate 1 Align the top of the wall plate to the station and angle the bottom approximately 20 degrees 2 Hook the top of the wall plate to the tabs located on the station electronics assembly To ensure the wall plate is hooked properly on the top hook wiggle it slightly side to side 3 Swing the bottom of the wall plate down until the m...

Page 44: ... the button lens To remove install or replace a button legend you must first remove the bezel and button lens from the station electronics 1 Remove the bezel from the station electronics Each corner of the bezel is provided with a notch to assist with bezel removal Use a nail to lift a corner free then gently remove the bezel from the station 2 Remove the button lens Using the pads of your thumb p...

Page 45: ...Function switch is set to Preset mode enables sequence toggle 2 Amber LED Disable When this switch is set to On amber button LEDs on the station will be disabled The default setting is Off Amber LEDs are provided as the default so the station glows in darkened spaces allowing it to be easily located 3 Space Combine Mode 4 button station only changes the station personality enabling space combine 4...

Page 46: ...trol mode MODE DIP 5 DIP 6 Push action Rotate action Intensity Off Off Selection Toggle Selection Raise Lower Color Temp Off On Toggle between Intensity and Color Temp Selection Raise Lower for Intensity and Color Temp HSI Color On Off Toggle between Intensity Saturation and Hue Selection Raise Lower for Intensity Saturation and Hue Studio On On Toggle between Intensity Color Temp and Tint Selecti...

Page 47: ...Station Miscellaneous 42 ...

Page 48: ...n Fax 604 815 0078 Email info echoflexsolutions com n Web echoflexsolutions com n Product information and specifications subject to change n 2018 Echoflex Solutions Inc n Echoflex intends this document to be provided in its entirety 8186M1220 3 1 0 n Revision A n Released 2018 09 ...

Reviews: