background image

ETC Installation Guide

ColorSource Fresnel V v1.1

FCC Compliance

ColorSource Fresnel V

(For any FCC matters):

Electronic Theatre Controls, Inc.
3031 Pleasant View Road
Middleton, WI 53562
+1 (608) 831-4116

etcconnect.com

This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received;
including interference that may cause undesired operation. Visit

etcconnect.com/products

for current and complete compliance

information including FCC compliance.

Note:

This equipment has been tested and found to comply with

the limits for a Class A digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful
interference to radio communications. Any modifications or
changes to this product not expressly approved by Electronic
Theatre Controls, Inc. could void the user’s authority to operate
the product. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be
required to correct the interference at their own expense.

This device contains a wireless module with the following identification
numbers:

FCC ID: VU65995

ISED Compliance

This device contains a license-exempt transmitter/receiver that complies
with Innovation, Science, and Economic Development Canada’s license-
exempt RSSs. Operation is subject to the following two conditions:

1. This device may not cause interference.
2. This device must accept any interference, including interference that

may cause undesired operation of the device.

Contains IC ID: 7480A-5995

CAN ICES-005 (A)

ColorSource Fresnel V

Page 15 of 16

ETC

Summary of Contents for ColorSource Fresnel V

Page 1: ...ecifications subject to change ETC intends this document to be provided in its entirety 7417M2100 1 1 Rev A Released 2022 10 Overview The ColorSource Fresnel V is an affordable LED fixture that uses the RGBIL red green blue indigo and lime color system to provide a rich bright light The fixture features motorized zoom and wireless configuration and control via NFC and the Set Light app The ColorSo...

Page 2: ...ur sur ou à côté d une surface inflammable Lorsque le luminaire est accroché l axe entre les points de fixation de la lyre doit être parallèle au sol Le montage du luminaire dans une orientation non parallèle risque de causer des dommages matériels ou corporels Débranchez le projecteur de son alimentation et du DMX et laissez le refroidir avant d installer des accessoires ou d effectuer un nettoya...

Page 3: ...afety device must be attached to the fixture The attachment loop is on the top of the fixture Leave as little slack as possible in the safety cable to avoid catching the yoke of the fixture Connectors Power Two powerCON TRUE1 connectors for power in and thru Data DMX512 RDM Two five pin XLR connectors for data in and thru Note The ColorSource Fresnel V is not self terminating You must terminate th...

Page 4: ...us the Fixture DOWN UP MODE DMX IN POWER THRU POWER IN ZOOM ZOOM Yoke locking knob Zoom encoder Turn to adjust zoom Press to enter Focus mode 1 Press the Zoom encoder to enter Focus mode All LEDs turn on at full and the display shows Foc 2 Turn the Zoom encoder to adjust the zoom between flood and spot Turn the encoder clockwise to adjust toward flood or counterclockwise to adjust toward spot 3 Pr...

Page 5: ...tton The display shows the current DMX control mode 4 Press the Up button or Down button to change the DMX control mode The currently saved mode is indicated by a decimal point at the end of the mode name Stn Standard mode intensity red green blue strobe zoom and fan This is the default mode dir Direct emitter control intensity red green blue indigo lime strobe zoom and fan 1ch 1 channel mode cont...

Page 6: ...lues that set these parameters DMX Parameter Values Parameter DMX Value Description Comments Fan 0 9 Auto As fixture temperature increases the fan speed increases to accommodate it 10 19 Off When the fixture gets too hot the fixture reduces the intensity instead of turning on the fan 20 Slow Minimum fan speed 21 248 Linear Increase in Speed Fan speed remains constant and intensity is reduced as ne...

Page 7: ...ity levels 201 240 No Strobe Shutter open 241 254 LEDs Off Shutter closed 255 No Strobe Shutter open Zoom 0 Full Spot 1 254 Linear Change from Spot to Flood 255 Full Flood Data Loss Behavior When DMX data is lost the fixture does one of the following actions If you selected a preset or sequence that preset or sequence automatically plays If no preset or sequence is active in the background the fix...

Page 8: ... shows rAd Radio and then press the Mode button to display the Multiverse settings 3 Use the Up button or Down button to navigate to the Multiverse setting that you want to change see table that follows Press the Mode button to select the setting use the Up button and Down button to modify it and then press the Mode button again to return to the Multiverse settings The currently saved mode is indi...

Page 9: ...L Signal Quality 1 100 Display of the signal quality Values above 50 are good signal quality and above 80 are excellent This value can be helpful when troubleshooting wireless performance SSi Signal Strength 20 120 Display of RSSI Received Signal Strength indicator in dBm ranging from 20 strongest to 120 weakest Note that the negative symbol does not display on the fixture A display of indicates t...

Page 10: ...matically If DMX data is present the current preset or sequence plays in the background and DMX data continues to take priority 2 Press the Up button or Down button as needed to scroll through the available presets and sequences 3 To stop the selected preset or sequence press the Mode button a second time The display will revert to show the DMX start address Pre configured Presets Zoom is set to 5...

Page 11: ...you want to edit 3 Press and hold the Mode button for 3 seconds The display shows L followed by either an intensity level from 0 99 or FL for full 4 Press the Up button or Down button to change the intensity level of the preset in real time 5 Press the Mode button to confirm your selection and return to the Presets Sequences menu If you don t press the Mode button the display returns to the Preset...

Page 12: ... do not need to disconnect them before pushing the updated fixture software The update process will ignore any other fixture types in the DMX run Note Not sure what version of fixture software is installed The version number appears on the display when the fixture powers up 1 Remove power and DMX In from the fixture that is running the software version that you want to push to other fixtures 2 Pre...

Page 13: ...issue Reload software to clear the error If the error persists contact ETC Technical Support visit etcconnect com contactETC LnS Indicates a motor power fault or a motor motion error If the error occurs regularly after a power cycle contact ETC Technical Support visit etcconnect com contactETC Specifications and Reference For current and complete compliance and specifications see the ColorSource F...

Page 14: ... ID 0x6574 Electronic Theatre Controls Model ID 0x0281 ColorSource Fresnel V with Multiverse 0x0282 ColorSource Fresnel V DMX Start Address 0x00F0 Range 1 512 DMX Personality 0x00E0 1 Standard 2 Direct 3 1 Channel 4 RGB Output Frequency 0x8123 0 Standard 5 kHz 1 High 25 kHz Multiverse Universe 0x8C05 Set the Universe value Multiverse SHoW ID 0x8C00 Set the SHoW ID value This value must match the S...

Page 15: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Any modifications or changes to this product not expressly approved by Electronic Theatre Controls Inc could void the user s authority to operate the product Operation of this equipment in a residential area is like...

Page 16: ...ent est soumis aux deux conditions suivantes 1 L appareil ne doit pas produire d interférences 2 L utilisateur de l appareil doit accepter toute interférence même si l interférence est susceptible d en compromettre le fonctionnement Contient ID IC 7480A 5995 CAN NMB 005 A Licensed Software This product uses licensed software provided by third parties Please visit etcconnect com licenses for licens...

Reviews: