ArcSystem Installation Manual
Chapter 4
Standard System Multi-Cell Installation
This chapter provides information on how to install all standard variants of multi-cell luminaires
in your ArcSystem installation.
Installing 100–240 V Multi-Cell Luminaires
100–240 V multi-cell yoke mounted luminaires include the Pro Two-Cell, Pro Four-Cell Linear,
Pro Four-Cell Square, and Pro Eight-Cell. For 100–240 V Pro Four-Cell Round, see
240 V Four-Cell Round Luminaires on the facing page
. For 100–277 V luminaires, see
100–277 V Multi-Cell Luminaires on page 32
.
Note:
Mounting hardware and installation location must support the weight of the
luminaire.
DMX
DMX In and DMX Thru cables terminate to RJ45 connectors. DMX is installed in a daisy chain
topology and includes one pair of wires (Data +, Data -) plus an ISO ground (common). ETC
recommends Cat5e (or better) minimum 24 AWG conductors terminated to T568B standard. Up
to 32 multi-cell luminaires can be connected per DMX run.
RJ45 Pinout Information
Pin
Description
1
Data +
2
Data -
7&8
ISO ground
(common)
Four-cell square
luminaire shown
DMX In and Thru
connections
Power switch
Power connection
Installation Procedure
1.
Attach a C-clamp or other mounting hardware (not provided) to the yoke of the luminaire.
2.
Attach the luminaire to a pipe or other approved mounting device.
3.
Insert or attach additional accessories, if desired.
4.
Connect the provided power cable.
5.
If using hard wired DMX, plug the RJ45 connector into the DMX in port on the rear of the
luminaire.
6.
If linking additional luminaires via DMX, plug a RJ45 cable into the DMX thru port on the
rear of the luminaire.