Chapter 4
Rack-Mount Driver Installation
This chapter provides instructions for installing the standard rack-mount models of ArcLamp
driver. Instructions for standard wall-mount, emergency wall-mount, and emergency rack-mount
drivers are in these chapters:
•
Wall-Mount Driver Installation on page 15
•
Emergency Driver Power Input Wiring on page 46
Note:
Install this device in a location with restricted access where only qualified
personnel and service persons can gain access with the use of a key. If this equipment is
installed in a location without restricted access, the wiring area of the rack should only
be accessible with the use of a tool.
Electrical and Wiring Specification
WARNING:
Circuits that are installed without an accessible power
disconnect device cannot be serviced or operated safely.
AVERTISSEMENT :
Il est imprudent d'utiliser ou de réparer les circuits
installés sans qu'un dispositif de déconnexion de l'alimentation ne soit
accessible.
The rack-mount ArcLamp Driver accepts 100–240 VAC, 50/60Hz. Emergency models only:
requires normal sense and maintained (emergency) input power. Wire and terminal
specifications are the same for all rack-mount drivers.