8.0 C
OMMISSIONING THE
P
UMP AND
C
ALIBRATION
8.1 HD-PH
(
COMMISSIONING THE PUMP
)
1
Suction hose connector nipple
11
Control panel
2 Delivery hose connector nipple
12
Electrode cable connector
3
Stroke Led (red)
13
Set-point selector “pH set”
4
Power Led (green)
15
Acid/Alk switch
5
Injection frequency regulation knob
16
Calibration trimmer
“pH/mV”
17
Calibration trimmer “
∆
0 “
6
Front cover fixing screw
18
Display
9
Fuse
10 Supply cable
a. Install the metering pump as described in Chapter 6.0 “P
UMP INSTALLATION
”.
b. Place the electrode in the electrode holder.
c. Connect the electrode to the metering pump by means of the male BNC connec-
tor (12), rotating it through 90°C.
d. Position the "pH set" knob (13) to the desired pH value, bearing in mind that the
scale dimensions are such as to give rise to a possible discordance between the
intervention point and the reading on the display (18). For example, if the "pH
set" knob is set to pH 7 and one then notes that pump has not yet come into
operation at pH 7.2, it would be desirable to carry out a check and, if necessary,
correct the set point by adjusting the "pH set" knob.
e. Use the "ACID/ALK" switch (15) to select the required type of intervention (acid
or alkaline). Example: If the intervention point is set at pH 9 and an acidification
is required, set the switch to ACID. The pump will then start dosing the addi-
tive every time the pH rises above 9. If it is desired to alkalinize the system, set
the switch to ALK, in which case the pump will come into operation every time
the pH drops below 9.
f. Use the FLOW knob (5) to set the number of injections per minute, reducing or
increasing the pump discharge according to requirements. In this connection it
36
ENG
fig.9
Summary of Contents for HD-PH
Page 2: ......
Page 4: ......
Page 85: ...Allegato Disegni Drawings Annexe des Dessins Dibujos Anexos 85...
Page 86: ...86...
Page 90: ...90 6401 6101 6501 6301 2401 1901 1801 Exx ELETTROMAGNETE COMPLETO COMPLETE ELECTROMAGNET...
Page 91: ...NOTE...
Page 92: ...NOTE...
Page 93: ...NOTE...
Page 94: ...NOTE...
Page 95: ......
Page 96: ...COD 4063 052 00...