ES920.1 - User’s Guide
25
ETAS
Getting Started
5.2
Disassembly
5.2.1
Removing the ES920.1 from the ES910 Module
To remove the ES920.1 from the ES910, you need a flat-bladed screwdriver
(width of edge 2 mm). To make removing the device simpler, make sure you
have two CBF100-2 FlexRay cables readily available.
To remove the ES920.1 from the ES910 module:
• Switch off the power supply to the ES910 module.
• Make sure that all devices connected to the module
with cables are powered off.
• Place the ES910 on a solid surface.
• Unscrew and remove the four screws from the cor
-
ners of the front panel of the extension slot.
Keep the screws in a safe place. They are needed to
attach the front panel.
• Connect one FlexRay cable to each of the FlexRay
ports.
• Get hold of the cables as near as possible to the
module.
• Slide the ES920.1 module out of the ES910 without
getting it off-line.
CAUTION!
Some components may be damaged or even destroyed by
static discharge!
Leave the module in its transport package until you want to install it.
The module should only be taken from its package and installed at a
working place that is protected against static discharge.
CAUTION!
Damage to the ES910 possible!
The ES910 module must not be stood on its back when the ES920.1
is being removed.
The mounting screws of the extension slot must not fall into the mod
-
ule.