Installation
FETK-T3.0 - User’s Guide
37
5.2.2
Connection to the ECU and to the Debugger
The FETK-T3.0 provides a connector for connecting 3rd party debugger and
trace tools. This connector (CON4) is located on the bottom side of the PCB.
CON4 is a Samtec 34 pin interface, and the cable should be procured from the
3rd party tool supplier. For additional details to connect the FETK-T3.0 to a 3rd
party debugger and trace tool, see Fig. 5-6.
Fig. 5-6
FETK-T3.0 Connection to the ECU and to the Debugger
ECU
Open Wires
M olex 87437-0543
+
Open Wire
M olex 87437-0543
ETAM 2
ETAM 5
or
ETAM 9
or
Debugger
Debugger cable to 34 pin Samtec
FETK-T3.0
CO
N
2
CON4
C
O
N1
Samtec ASP-137973-01
ETAN2 or ETAN8
Open Wires
ETV5