Universal Coil-On-Plug Ignition Flex Probe Kit Operating Instructions
Page 2
F-00K-104-952
for comparison measurements between individual ignition coil circuits. Voltage readings observed on the
tester may not represent actual voltage levels in the circuit.
CONNECTION AND OPERATION
Universal COP Ignition Flex Probe
Use this probe when performing diagnostics on most secondary ignition coil-on-plug systems.
1. Turn on the engine analyzer and select
Secondary Quick Check
from the tester’s main menu.
2. Connect the circular black connector of the Flex Probe to the
SEC IGN
input of the analyzer.
3. With the vehicle running, place the tip of the flexible probe as close to the ignition coil as you can to
obtain a signal.
4. When a signal appears on the tester’s screen, adjust the Volts/Div setting for optimum signal viewing.
5. Repeat steps 1-3 to view each cylinder for comparison.
Please note that when comparing measurements of individual cylinders, the probe must always be held at the
same distance and position to the coil for each cylinder being analyzed.
WARNING!
SAFETY INSTRUCTIONS
• Do not attempt to touch moving or rotating parts with this probe when
the engine is running. Always make sure when using these probes that
it does not come into contact with moving parts.
• Do not route tester cables near moving parts.
• Ignition systems produce high voltages which can cause serious injury
or death when direct contact is made with defective and disassembled
ignition components. To avoid shock from electrical systems while
vehicle is in operation, always inspect ignition components under test
before connecting test equipment.