Operation
13
2.4
Cabling and Operation
The order in which you attach the cables to the interfaces of the ES590 is
irrelevant. The interface cable for the host PC and the power supply cable for
the ES590 are part of the standard delivery scope. You can order other cables
in various lengths from ETAS.
The maximum cable length for the individual interfaces are specified in the
following table:
To start up the ES590:
•
Connect the ECUs used with the relevant inter-
faces on the front of the device.
SMB measuring devices can be connected with
the
SERIAL
interface on the back of the device.
Measuring devices at the serial measuring bus
have to have a separate power supply as they are
not supplied by the ES590.
•
Use the CBE 100-3 cable supplied for connecting
the host PC and the ES590. Plug it into the
Host
interface on the back of the device and the rele-
vant output of your Ethernet board at the PC.
•
Use the CBP 100-2 cable supplied for the power
supply. Plug it into the
6-32 V
interface on the
back of your device and the continuous plus in
the vehicle.
note
Carefully check the software version numbers and cable names. Wrong software
versions and cables could impair the proper functioning of your ES590 or dam-
age the ES590 and the connected devices.
Interface Maximum Cable Length
ETK
20 m
CAN
4 m at 1 MBit/s. The transfer rate decreases the longer the cable is.
K-Line
8 m at 250 kBaud. The max. admissible cable length is project-specific.
6–32 V
2 m trouble-free operation guaranteed at UBatt 6 V.
SERIAL
8 m
HOST
20 m