General Information

9

1.1.2

Correct Use

ETAS GmbH cannot be made liable for damage which is caused by incorrect 
use and not adhering to the safety instructions.

1.1.3

Labeling of Safety Instructions

The safety instructions contained in this manual are shown with the standard 
danger symbol shown below:

The following safety instructions are used. They provide extremely important 
information. Please read this information carefully.    

1.1.4

Demands made re the Technical State of the Product

The following requirements are made to ensure safe operation of the module:

• Ensure you observe the notes on environmental conditions (see section 

5.1.2 on page 37).

• Ensure you adhere to the port and setting values (see section 5.3.1 

on page 39 and section 5.3.2 on page 40).  

WARNING!

Indicates a possible medium-risk danger which could lead to seri-
ous or even fatal injuries if not avoided.

CAUTION!

Indicates a low-risk danger which could result in minor or less seri-
ous injury or damage if not avoided.

CAUTION!

The module can be damaged or destroyed!

 

Do not open or change the module!

 

Work on the module must only be carried out by specialist, quali-
fied personnel.

Manual.book  Seite 9  Montag, 13. Juli 2009  6:24 18

Summary of Contents for ES511.1

Page 1: ...ES511 1 CAN and LIN Network Module User s Guide Manual book Seite 1 Montag 13 Juli 2009 6 24 18 ...

Page 2: ... and copying is only allowed in concurrence with the specifications stipulated in the contract Under no circumstances may any part of this document be copied repro duced transmitted stored in a retrieval system or translated into another language without the express written permission of ETAS GmbH Copyright 2009 ETAS GmbH Stuttgart The names and designations used in this document are trademarks or...

Page 3: ...made re the Technical State of the Product 9 1 2 Taking the Product Back and Recycling 10 1 3 About This Manual 11 1 3 1 Structure 11 1 3 2 Using this Manual 12 1 4 Package Contents 13 2 Hardware Description 15 2 1 Modules of the ES51x Line 15 2 2 ES511 1 Features 15 2 3 Housing 17 2 4 Serial Number 17 2 5 Ports 17 2 5 1 Front Panel 17 2 5 2 Back Panel 18 Manual book Seite 3 Montag 13 Juli 2009 6 ...

Page 4: ...on the Bus 24 3 6 FlexRay Interface FLEXRAY A FLEXRAY B 25 3 6 1 Feature 25 3 6 2 Bus Termination Resistor 25 3 7 Module Network 26 3 8 Time Synchronization 26 3 9 Firmware Update 27 4 Getting Started 29 4 1 Applications 29 4 1 1 ES511 1 with XETK ES590 and ES400 Modules 29 4 1 2 ES510 1 with ES511 and ES512 Measure Modules 30 4 2 Wiring 31 4 2 1 HOST Port 31 4 2 2 6 32V Port 31 4 2 3 ETH1 ETH2 ET...

Page 5: ...ment 42 5 4 1 Interface 6 32V 42 5 4 2 Interface HOST 43 5 4 3 Interface ETH1 43 5 4 4 Interface ETH2 44 5 4 5 Interface ETH3 44 5 4 6 Interface CAN 1 45 5 4 7 Interface CAN 2 45 5 4 8 Interface LIN 1 46 5 4 9 Interface LIN 2 46 6 Cable and Accessories 47 6 1 Power Supply Cable 47 6 2 Ethernet Cable 48 6 2 1 CBE500 3 Cable 48 6 2 2 CBE530 x Cable 48 6 3 CAN LIN FlexRay Cable 49 6 3 1 CAN Terminati...

Page 6: ...oblems 53 8 3 Problems and Solutions 54 8 3 1 Network Adapter cannot be selected via Network Manager 54 8 3 2 Search for Ethernet Hardware fails 55 8 3 3 Personal Firewall blocks Communication 57 9 ETAS Contact Addresses 63 List of Figures 65 Index 67 Manual book Seite 6 Montag 13 Juli 2009 6 24 18 ...

Page 7: ...ous personal injury or property damage Do not use this ETAS product if you do not have the proper experience and training Also if a product issue develops ETAS will prepare a Known Issue Report KIR and post it on the internet The report includes information regarding the technical impact and status of the solution Therefore you must check the KIR applicable to this ETAS product version and follow ...

Page 8: ...IF YOU FAIL TO FOLLOW THESE INSTRUCTIONS THERE MIGHT BE A RISK OF DEATH SERIOUS INJURY OR PROPERTY DAMAGE THE ETAS GROUP OF COMPANIES AND THEIR REPRESENTATIVES AGENTS AND AFFILIATED COMPANIES DENY ANY LIABILITY FOR THE FUNCTIONAL IMPAIRMENT OF ETAS PRODUCTS IN TERMS OF FITNESS PERFORMANCE AND SAFETY IF NON ETAS SOFTWARE OR MODEL COMPONENTS ARE USED WITH ETAS PRODUCTS OR DEPLOYED TO ACCESS ETAS PRO...

Page 9: ...owing requirements are made to ensure safe operation of the module Ensure you observe the notes on environmental conditions see section 5 1 2 on page 37 Ensure you adhere to the port and setting values see section 5 3 1 on page 39 and section 5 3 2 on page 40 WARNING Indicates a possible medium risk danger which could lead to seri ous or even fatal injuries if not avoided CAUTION Indicates a low r...

Page 10: ...no danger to health or the environment Fig 1 1 WEEE Symbol The WEEE symbol see Fig 1 1 on page 10 on the product or its packaging shows that the product must not be disposed of as residual garbage The user is obliged to collect the old devices separately and return them to the WEEE take back system for recycling The WEEE directive concerns all ETAS devices but not external cables or batter ies For...

Page 11: ...on and the firmware update Chapter 4 Getting Started The Getting Started chapter includes application examples and notes on the wiring of the ES511 1 Chapter 5 Technical Data The Technical Data chapter contains a summary of all technical data and the pin assignments of the ES511 1 module Chapter 6 Cables and Accessories The Cables and Accessories chapter contains an overview of the available cable...

Page 12: ...Possibly an explanation of step 2 Step 3 Possibly an explanation of step 3 Any concluding remarks Typographic Conventions The following typographic conventions are used Important notes for the user are shown as follows Select File Open Menu functions are shown in boldface blue Click OK Buttons are shown in boldface Press ENTER Keyboard commands are shown in angled brackets in block capitals The Op...

Page 13: ...ll required parts and cables see chapter 7 1 on page 51 Additional cables and adapters can be ordered separately from ETAS A list of available accessories and ordering information can be found in the chapter 7 2 on page 51 of this manual or in the ETAS product catalog Manual book Seite 13 Montag 13 Juli 2009 6 24 18 ...

Page 14: ...General Information 14 Manual book Seite 14 Montag 13 Juli 2009 6 24 18 ...

Page 15: ...s have three downstream Ether net interfaces that can be connected with ES51x ES600 measurement and interface modules Fig 2 1 ES511 1 View of the Device Individual measurement calibration and rapid prototyping modules are easy to combine with ES51x line modules ECUs that have an XETK or ECUs that have their own Ethernet interface can be connected directly with an ES51x module and communicate with ...

Page 16: ... Baud rate can be configured by software Two independent LIN interfaces LIN specification LIN V2 1 Operating mode Slave monitoring Transceiver Physical layer MCZ33661EF Additional features of the module Module suitable for use in automotive applications suitable for use in the development environment and in the vehicle on test drives Channels galvanically isolated from each other from the device g...

Page 17: ...evice 2 5 Ports 2 5 1 Front Panel The ES511 1 has an Ethernet port upstream to the host PC or to superordi nate ES51x modules three Ethernet ports downstream for further ES510 1 and or measurement and interface modules and a power supply port RJ 45 compatible Neutrik ports are used at the Ethernet ports The following ports are on the front of the ES511 1 6 32V operating voltage HOST Ethernet SYNC ...

Page 18: ...the operational error and synchroni zation state of the module as well as with LEDs which display the functional state of the assigned Ethernet interface LED Display ON ER Operational state and possible error states of the module SYNC Synchronization state of the module TX Function of the HOST interface TX Function of the assigned ETHx interface one LED each for ETH1 ETH2 ETH3 Manual book Seite 18...

Page 19: ...ooting or booting was unsuccessful Red flashing 500 ms on 500 ms off Firmware update in progress Green flashing 100 ms on 900 ms off Operational state Standby Green Operational state On Off No power supply LED Display Operational State SYNC Blue flashing fully bright The module is a synchronization master the module is not synchronized exter nally Blue flashing lsemi and fully bright alternately T...

Page 20: ...Hardware Description 20 Manual book Seite 20 Montag 13 Juli 2009 6 24 18 ...

Page 21: ...by 3 3 Ethernet Switch The integrated Ethernet switch is used for the connection of the ES511 1 mod ule and other measurement or interface modules to a user PC Data from the connected modules of the ES51x line is acquired synchronously ETAS device Power Supply 6 32V Ethernet Traffic Detection Time Synchronization Unit ETH 3 6 32V Ethernet Phy ETH 2 ETH 1 HOST Ethernet Phy Ethernet Phy Ethernet Phy...

Page 22: ...olated from each other and from the power supply 3 3 1 HOST Port The upstream Ethernet interface HOST combines the ES511 1 module with the user PC or a further module of the ES51x line This interface allows the ETAS software tools access to the connected modules 3 3 2 ETH1 ETH2 ETH3 Port The downstream Ethernet interfaces ETH1 ETH2 and ETH3 connect the ES511 1 module to other ES51x modules measure...

Page 23: ...One each of the CAN interfaces is routed to the two 9 pin CAN 1 and CAN 2 connectors DSUB socket on the back panel CAN 1 and CAN 2 are complete independent CAN channels with sepa rated connections and CAN controllers The CAN interfaces produce a simple and direct connection between the ES511 1 and the CAN network The interfaces are galvanically isolated from each other and from the other interface...

Page 24: ...nd LIN 2 connectors DSUB socket on the back panel LIN 1 and LIN 2 are completely independent LIN interfaces with separate connections and LIN controllers The LIN interfaces establish a simple and direct connection between the ES511 1 and the LIN network The interfaces are gal vanically isolated from each other and from the other interfaces of the ES511 1 and are also protected against overload and...

Page 25: ...ent FlexRay channels with separated connections The FlexRay interfaces produce a simple and direct connection between the ES512 1 and the FlexRay network The interfaces are galvanically isolated from each other and from the other interfaces of the ES512 1 3 6 1 Feature You can find a list of FlexRay applications supported by the ES512 1 in chapter 5 2 3 on page 38 3 6 2 Bus Termination Resistor Th...

Page 26: ...aster synchronizes the connected modules via the Ethernet lines The synchronization signal is relayed to con nected modules at the ETH1 ETH2 and ETH3 interfaces SYNC OUT The ES51x slave modules adapt to the clock pulse specified by the master mod ule The periodic synchronization signal is superimposed onto the Ethernet signals without affecting data transfer This excludes the possibility of a phas...

Page 27: ...y the user so that future ver sions of the module can also be implemented The firmware is updated on the connected PC using service software Note Neither the power supply nor the Ethernet connection can be interrupted during a firmware update Manual book Seite 27 Montag 13 Juli 2009 6 24 18 ...

Page 28: ...Functional Description 28 Manual book Seite 28 Montag 13 Juli 2009 6 24 18 ...

Page 29: ...S511 1 with XETK ES590 and ES400 Modules Cable in Fig 4 1 Function Short Name 1 Power supply cable CBP510 2 2 PC connecting cable CBE500 3 3 Ethernet connecting cable CBE530 x 4 PC connecting cable CBE200 x 5 ECU Adapter cable CBAM230 CBAM240 6 PC connecting cable CBE100 x 7 PC connecting and power supply cable ES4xx CBEP410 x 3 1 6 32V DC 4 1 6 32V DC 2 7 6 ES590 ES591 ES510 ES510 ES400 XCP on Et...

Page 30: ...ng cable CBE530 x 4 PC connecting cable CBE200 x 5 ECU Adapter cable CBAM230 CBAM240 6 PC connecting cable CBE100 x 7 PC connecting and power supply cable ES4xx CBEP410 x 3 1 6 32V DC 4 2 6 ES590 ES591 ES511 ES510 Ethernet Application Ethernet CAN XETK ETK ECU ECU XCP on Ethernet ETK Interface CAN Interface 5 1 6 32V DC ES512 3 1 6 32V DC Ethernet ECU ECU CAN Interface 7 7 CAN Interface LIN Interf...

Page 31: ...he HOST port of the ES511 1 with the PC interface cable CBE500 2 or Connect the HOST port of the ES511 1 with an Ethernet patch cable Connect the cable s RJ 45 connector with the free Ethernet interface of your PC 4 2 2 6 32V Port To connect the ES511 1 Network Module with the power supply you require the CBP510 2 cable provided To connect the ES511 1 with the power supply Connect the CBP510 2 pow...

Page 32: ...a single ES511 1 module with connected measure modules ES51x measure modules are used in the following example To connect an ES511 1 with ES51x measure modules Connect the ETH1 port of the ES511 1 with the Ethernet cable CBE530 x or Connect the ETH1 port of the ES511 1 with an Ethernet patch cable Connect the second cable connector with the HOST port of an ES51x measure module Connect further modu...

Page 33: ...module with other ES51x modules To cascade an ES51x module connect the HOST port of the subordinate ES51x module with one of the ETH1 to ETH3 ports of the superordinate ES51x module The superordi nate ES51x module is nearer the host PC in the hierarchy Connect further ES51x modules in accordance with this principle with the ETH2 and ETH3 ports of the ES51x module ES51x ES512 ES51x ES511 ES511 ES51...

Page 34: ...o the PC Start the HSP program on the PC Click Hardware Search Highlight the ES511 1 to be configured in the Hardware window Right click System Configuration The default web browser launches the web interface for configuring the ES511 1 with the current IP address of the module in the address field The home page of the ES511 1 web interface is displayed 4 3 3 Configuring the Auto On Switch Functio...

Page 35: ...Getting Started 35 The HOST interface is activated if the mod ule is energized Manual book Seite 35 Montag 13 Juli 2009 6 24 18 ...

Page 36: ...Getting Started 36 Manual book Seite 36 Montag 13 Juli 2009 6 24 18 ...

Page 37: ...io disturbances by additional shielding measures 5 1 2 Environmental Conditions Norm Test EN 61326 Electrical equipment for measure ment control and laboratory use EMC requirements EN 61000 6 2 Immunity industrial environments EN 61000 6 4 Emission standard industrial environ ments WARNING This is a class A product In a domestic environment this product may cause radio interference in which case t...

Page 38: ... this func tion Example Link down Power saving 5 2 3 Supported Applications and Software Requirements Software in the following versions is required to configure and control the ES511 1 and for data acquisition purposes Dimensions H x W x D 52 mm x 169 mm x 107 mm 2 05 in x 6 65 in x 4 25 in Weight 520 g 1 43 lb Note It is imperative you disable the function which automatically switches to power s...

Page 39: ... 2 1 1 MC Measurement and Calibration Connection 10 100Base T Ethernet Full Duplex PC Card 32 bit Protocol Ethernet Switching Layer 2 IEEE802 3 Note To ensure successful initialization of the network card of your PC refer to chapter 5 2 2 on page 38 Support in Application Software Inter face Application Classifi cation 1 INCA INTECRIO ASCET RP Manual book Seite 39 Montag 13 Juli 2009 6 24 18 ...

Page 40: ...0 100 MBit s Protocol TCP IP Resolution synchronization 1 μs Upstream connection PC Laptop ES510 1 Network Module ES51x Measurement Modules Downstream connection ECUs with XETK ECUs with Ethernet interface ES510 1 Network Module ES600 Network Module ES400 Measurement Modules ES51x Measurement Modules ES590 ES591 Interface Modules 1 ES910 2 Rapid Prototyping Module 1 ES910 3 Rapid Prototyping Modul...

Page 41: ...d Identifier CAN V2 0b Extended Identifier Controller IP Core FPGA Transceiver Physical Layer TJA1040 Transfer speed Max 1 MBaud with a bus length of 20 m LIN 1 and LIN 2 2 independent interfaces galvanically isolated from each other and from the other interfaces Specification LIN V2 1 Controller IP Core FPGA Transceiver Physical Layer MCZ33661EF Operating mode Slave Monitoring Manual book Seite 4...

Page 42: ... Interface 6 32V Fig 5 1 Interface 6 32V Note All connectors are shown with a view of the interfaces of the ES510 1 Pin Signal Meaning 1 Reserved 2 UBATT Supply voltage plus 3 Ground Ground 3 1 2 Manual book Seite 42 Montag 13 Juli 2009 6 24 18 ...

Page 43: ...ed 5 n c Reserved 6 ETH1_TX Send data minus 7 n c Reserved 8 n c Reserved G ETH1_GND Ground interface HOST Pin Signal Meaning 1 ETH2_TX Received data plus 2 ETH2_TX Received data minus 3 ETH2_RX Send data plus 4 n c Reserved 5 n c Reserved 6 ETH2_RX Send data minus 7 n c Reserved 8 n c Reserved G ETH2_GND Ground interface ETH1 Manual book Seite 43 Montag 13 Juli 2009 6 24 18 ...

Page 44: ...ed 5 n c Reserved 6 ETH3_RX Send data minus 7 n c Reserved 8 n c Reserved G ETH3_GND Ground interface ETH2 Pin Signal Meaning 1 ETH4_TX Received data plus 2 ETH4_TX Received data minus 3 ETH4_RX Send data plus 4 n c Reserved 5 n c Reserved 6 ETH4_RX Send data minus 7 n c Reserved 8 n c Reserved G ETH4_GND Ground interface ETH3 Manual book Seite 44 Montag 13 Juli 2009 6 24 18 ...

Page 45: ...served 5 CAN 1_Shield Cable shield 6 n c Reserved 7 CAN 1_H CAN HIGH 8 n c Reserved 9 CAN 1_UBatt CAN UBATT Pin Signal Meaning 1 n c Reserved 2 CAN 2_L CAN LOW 3 CAN 2_UBatt CAN GND 4 n c Reserved 5 CAN 2_Shield Cable shield 6 n c Reserved 7 CAN 2_H CAN HIGH 8 n c Reserved 9 CAN 2_UBatt CAN UBATT Manual book Seite 45 Montag 13 Juli 2009 6 24 18 ...

Page 46: ... n c Reserved 5 LIN 1_Shield Cable shield 6 n c Reserved 7 LIN 1 LIN 8 n c Reserved 9 LIN 1_UBatt LIN UBATT Pin Signal Meaning 1 n c Reserved 2 n c Reserved 3 LIN 2_UBatt LIN GND 4 n c Reserved 5 LIN 2_Shield Cable shield 6 n c Reserved 7 LIN 2 LIN 8 n c Reserved 9 LIN 2_UBatt LIN UBATT Manual book Seite 46 Montag 13 Juli 2009 6 24 18 ...

Page 47: ...ble cables and accessories 6 1 Power Supply Cable Fig 6 1 CBP510 2 Cable Side A Side B Side A Side B Pin Signal Plug Signal 1 n c Red UBATT 2 UBATT Black Ground 3 Ground Product Length Order Number CBP510 2 2 m F 00K 106 273 CBP510 2 F 00K 106 273 Power Supply Cable 0000 Manual book Seite 47 Montag 13 Juli 2009 6 24 18 ...

Page 48: ...E530 x Cable Note You can also use Ethernet patch cables 1 1 twisted pair Cat5 in limited environmental conditions e g in the lab Product Length Order Number CBE500 3 3 m F 00K 106 275 Product Length Order Number CBE500 0m45 0 45 m F 00K 106 274 CBE500 3 3 m F 00K 106 362 Manual book Seite 48 Montag 13 Juli 2009 6 24 18 ...

Page 49: ...g Resistor Fig 6 5 CBCX131 0 Terminating Resistor Product Length Order Number CBH500 2 2 m F 00K 106 276 Product Length Order Number CBCX131 1 0 F 00K 103 786 CBH500 2 F 00K 106 276 CAN LIN FLX 0000 FMH1 5 4 3 2 1 6 7 8 9 5 4 3 2 1 9 8 7 6 120 Ohm Manual book Seite 49 Montag 13 Juli 2009 6 24 18 ...

Page 50: ...Cable and Accessories 50 Manual book Seite 50 Montag 13 Juli 2009 6 24 18 ...

Page 51: ...trik NC3FXX Banana 3mc 2mc 2 m CBP510 2 F 00K 106 273 Order Name Short Name Order Number Ethernet PC Connection Cable Neutrik NE8MC1 RJ45 RJ45 9mc 9mc 3 m CBE500 3 F 00K 106 275 Ethernet Cable Neutrik NE8MC1 RJ45 Neutrik NE8MC1 RJ45 9mc 9mc 0m45 CBE530 0m45 F 00K 106 274 Ethernet Cable Neutrik NE8MC1 RJ45 Neutrik NE8MC1 RJ45 9mc 9mc 3 m CBE530 3 F 00K 106 362 Order Name Short Name Order Number CAN...

Page 52: ...g Informationen 52 7 2 4 CAN Termination Resistor Order Name Short Name Order Number CAN Termination Resistor 120 Ohm 2xDSUB 9fc 9mc 0 m CBCX131 0 F 00K 103 786 Manual book Seite 52 Montag 13 Juli 2009 6 24 18 ...

Page 53: ...e following table lists some of the possible problems with a remedy If you have any further questions please contact our Customer Support see chapter 9 on page 63 Problem Diagnostic Questions Possible Solutions Data is lost during data transfer Are you using WLAN in your test setup WLAN is not permissible within this ETAS net work Wire your test setup ETAS modules and their connection to the PC wi...

Page 54: ...etwork administrator To enable the APIPA mechanism Open the Registry Editor Windows XP Click Start and then click Run Enter regedit and click OK Windows Vista Click Start enter regedit in the entry field and push ENTER The registry editor is displayed Open the folder HKEY_LOCAL_MACHINE SYSTEM CurrentControlSet Services Tcpic Parameters Click Edit Find to search for the key IPAutoconfigurationEnabl...

Page 55: ...d for tunneling filters messages As an example Cisco VPN clients with versions before V4 0 x in some cases erroneously filtered certain UDP broadcasts If this might be the case please update the software of your VPN client Cause ETAS Hardware hangs Occasionally the ETAS hardware might hang In this case switch the hardware off then switch it on again to re initialize it Cause Network Adapter tempor...

Page 56: ...etwork adapter right click on it again and select Enable Cause Laptop power management deactivates the network card The power management of a laptop computer can deactivate the network card Therefore you should turn off power monitoring on the laptop To switch off power monitoring on the laptop From the Windows Start Menu select Windows XP Control Panel System Then select the Hardware tab and clic...

Page 57: ... typically cannot find any Ethernet hardware at all although the configuration parameters are correct Certain actions in ETAS products may lead to some trouble if the firewall is not properly parameterized e g upon opening an experiment in ASCET or search ing for hardware from within INCA or HSP If a firewall is blocking communication to ETAS hardware you must either dis able the firewall software...

Page 58: ...r for each personal firewall software used Therefore please refer to the user documentation of your personal firewall software for further details As an example for a firewall configuration you will find below a description on how to configure the widely used Windows XP firewall if the hardware access is prohibited under Windows XP with Service Pack 2 Solution for Windows XP Firewall Users with Ad...

Page 59: ...n survives a restart of the program or even the PC Instead of waiting for the Windows Security Alert dialog window you can unblock ETAS products in advance To unblock ETAS products in the firewall control From the Windows Start Menu select Settings Control Panel In the control panel double click the Win dows Firewall icon to open the Windows Firewall dialog window Manual book Seite 59 Montag 13 Ju...

Page 60: ... This tab lists the exceptions not blocked by the firewall Use Add Program or Edit to add new programs or edit existing ones Make sure that the ETAS products and ser vices you want to use are properly configured exceptions Open the Change Setup window Manual book Seite 60 Montag 13 Juli 2009 6 24 18 ...

Page 61: ...ify priv ileges within the ETAS ETASData and ETAS temporary directories Other wise an error message opens if the product is started and a database is opened In that case no correct operation of the ETAS product is possible because the database file and some ini files are modified during opera tion The ETAS software has to be installed by an administrator anyway It is recom mended that the administ...

Page 62: ...e the option For this program don t show this message again Click OK to close the window An administrator has to select the respective ETAS software in the Exceptions tab of the Windows Firewall dialog window to avoid further problems regarding hardware access with that ETAS product Manual book Seite 62 Montag 13 Juli 2009 6 24 18 ...

Page 63: ...s well as your local technical support team and product hotlines take a look at the ETAS website Borsigstraße 14 Phone 49 711 89661 0 70469 Stuttgart Fax 49 711 89661 106 Germany WWW www etas com ETAS subsidiaries WWW www etas com en contact php ETAS technical support WWW www etas com en hotlines php Manual book Seite 63 Montag 13 Juli 2009 6 24 18 ...

Page 64: ...ETAS Contact Addresses 64 Manual book Seite 64 Montag 13 Juli 2009 6 24 18 ...

Page 65: ...IN Bus 25 Fig 4 1 ES511 1 with XETK ES590 and ES400 Modules 29 Fig 4 2 ES510 1 with ES511 and ES512 Measure Modules 30 Fig 4 3 Example of a Module Network 33 Fig 5 1 Interface 6 32V 42 Fig 6 1 CBP510 2 Cable 47 Fig 6 2 CBE500 3 Cable 48 Fig 6 3 CBE530 x Cable 48 Fig 6 4 CBH500 2 Cable 49 Fig 6 5 CBCX131 0 Terminating Resistor 49 Manual book Seite 65 Montag 13 Juli 2009 6 24 18 ...

Page 66: ...66 Manual book Seite 66 Montag 13 Juli 2009 6 24 18 ...

Page 67: ... Terminating Resistor 24 CAN bus termination resistor 25 CAN Interface CAN 1 CAN2 23 CAN interfaces 41 CAN LIN FlexRay Cable 49 51 Cascading modules 26 CBCX131 0 Terminating Resistor 49 Clock pulse 26 Correct Use 9 D Data electrical 39 mechanical 38 E Electrical data 39 ETAS Contact Addresses 63 ETAS device synchronization 26 Ethernet Cable 48 Ethernet Cables 51 Ethernet Interfaces 40 Ethernet pat...

Page 68: ...ions 12 Use Case 12 Ordering Informationen 51 P Package contents 13 Phase shift 26 Pin Assignment 42 Ports 17 Power Supply 40 Power supply 21 Power Supply Cable 47 Power Supply Cables 51 Power saving feature 23 Product Back 10 Product liability disclaimer 7 R Recycling 10 Reference level 25 Representation of Information 12 S Safety Instructions Labeling of 9 Serial number 17 Standards 37 Standards...

Page 69: ...Index 69 W Waste Electrical and Electronic Equipment 10 WEEE 10 WEEE take back system 10 Wiring 31 Manual book Seite 69 Montag 13 Juli 2009 6 24 18 ...

Reviews: