Hardware
13
2.2
Configuration
This section describes possible configurations of the ES4434.1 Configurable
Load Board.
These are:
• "Exchanging Load Resistors" on page 13
• "Configuring Loads on Battery Nodes" on page 14
• "Configuring Grounds" on page 15
Exchanging Load Resistors
The ES4434.1 Configurable Load Board is fully equipped with 24 510
Ω
resistors on delivery. They can be replaced at any time with other resistors –
please note that the maximum permissible power per load is 3 W.
To exchange resistors on the ES4434.1 Configurable Load Board, proceed as
follows:
• If the board is installed in the ES4408.1 Load
Chassis, switch off the power supply voltage
to the housing.
• Remove the screws with which the ES4434.1
is attached in the housing and pull out the
board.
• Remove the relevant resistors by pressing
down the white clips.
• Insert the new resistors.
Summary of Contents for ES4434.1