![eta Hack 200 kW Service Manual Download Page 4](http://html1.mh-extra.com/html/eta/hack-200-kw/hack-200-kw_service-manual_2430170004.webp)
4
www.eta.co.at
Maintenance notes
Cleaning and maintenance
2
Cleaning and maintenance
2.1
Maintenance notes
Performing regular cleaning and maintenance
To ensure satisfactory functionality, cleaning and
maintenance must be performed at regular intervals.
You will receive a timely reminder about this from the
ETAtouch control system.
Cleaning of the boiler must be carried out at least
once a year, or when requested by the control
system. Maintenance is necessary at least every
3 years, or when requested by the control system. We
recommend that you perform maintenance annually.
You can also enter into a service agreement for your
heating system. Find out more from your heating
contractor or customer service.
All tasks where the maintenance table reads
"Customer" or "Customer or expert" in the column
"To be carried out by" can be carried out by any trained
adult. Instruction may be provided by the heating
technician or our customer service.
Steps that are marked with "Expert" only can only be
carried out by the heating technician or our customer
service.
Operation only by trained personnel
The product may be operated by trained adults only.
Training may be provided by the heating technician or
our customer service. Please read the associated doc-
umentation carefully in order to avoid errors during
operation and maintenance.
Persons who lack experience and knowledge as well
as children may not operate, clean, or maintain the
product.
Explanation of pictograms
Clean panels
If necessary, clean the panels of the boiler and the
ETAtouch screen with a moist cloth.
Switch the boiler on/off with the mains
switch.
Perform a visual check of the components.
Clean the components with a soft cloth, for
example.
Remove deposits with a vacuum cleaner or
an ash vacuum.
Remove deposits with the poker.
Remove deposits with the cleaning brush.
Replace the wear parts (e.g., seals) with new
items.
Lubricate the components. The lubricant to
use is listed in the respective step.
Mount the components (e.g., screws or nuts)
by hand only, without tools.
Install the components with some force (e.g.,
the retaining tube or the Lambda probe).
Handle the components carefully, since they
break very easily.
Measure or check dimensions or clearances
on the components.
Mark the components so that the correct
position can be found, for example, when
mounting.
Wear a protective mask to avoid injuries to
the airways.
Seal the components. The sealant to use is
listed in the respective step.
Use glue to adhere the seals, for example.
Do not use compressed air to clean the
components.
Do not use cleaning brushes to clean the
components.
Do not use an ash vacuum or vacuum
cleaner.
Do not lubricate the components.
No water or moisture in this area.