24
www.eta.co.at
Getting to know the control system
ETAtouch controller
If the error symbol at the bottom of the screen is
tapped, a window appears. In this, the function block in
which the error occurred will be displayed.
Fig. 6-10: Display of the function blocks in which the error
occurred
If the function block is selected, the view changes to
the messages menu. By tapping the error, the error
description is displayed.
Fig. 6-11: Error description
To acknowledge, press the [Acknowledge] button.
Depending on the nature of the fault, this either
remains visible or disappears.
You can also switch to the messages menu to
display any errors. Just tap on the
symbol and then select
.
6.1.5
Inputs and outputs
See terminal assignment of individual
components
The terminal assignments of the individual
components of the selected function block are
displayed in the inputs and outputs menu, e.g. pumps,
temperature sensors, and mixers.
When authorization is given, the terminal
assignment can be changed. Also, manual mode
for, e.g. a pump or a mixer, is possible.
Below is an example of the function block of the
heating circuit. To view the terminal assignment, first
select the heating circuit. To access the inputs and
outputs menu, tap on the
symbol, followed by
. An overview screen opens.
Fig. 6-12: Overview
Details of a component, such as the current situation
or the operating state, are displayed when the
symbol is tapped. Try this with the heating circuit
mixing valve. A settings window appears.
Fig. 6-13: Settings window
With the appropriate authorization, the heating
circuit mixing valve can be manually put into
operation in the settings window using the [Forward],
[Back] and [Stop] buttons. However, this is primarily
intended for specialists.
Close the settings window using the arrow on the left
side.
Summary of Contents for HACK 20
Page 1: ...2017 01 30 EN 0000000294 V 003 2 38 0 3005 3106 93526 001 Wood chip boiler 20 90 kW Operation ...
Page 15: ...Changing the fuel Settings 15 4 2 Settings ...
Page 35: ...ETAtouch controller Boiler function block HACK 35 ...
Page 45: ...ETAtouch controller Buffer function block 45 ...
Page 49: ...ETAtouch controller Hot water tank function block 49 ...
Page 53: ...ETAtouch controller Fresh water module function block 53 ...
Page 67: ...ETAtouch controller Solar function block 67 ...
Page 73: ...ETAtouch controller Heating pipeline function block 73 ...
Page 92: ...www eta co at www eta co at downloads DOWNLOAD ...