28
www.eta.co.at
Maintenance (expert)
Cleaning and maintenance
2.6
Maintenance (expert)
2.6.1
Preparation
Before this maintenance, perform all steps for the
preceding maintenance intervals
Before this maintenance, all steps for the
preceding maintenance intervals must be
performed.
WARNING!
The following activities may only be performed by
qualified specialist personnel.
If you carry out these activities without the correspond-
ing specialist training, and above all without the
required experience, safe operation is no longer
guaranteed. The resulting defects and consequential
damage are excluded from the guarantee and
warranty.
Equally an incorrect performance of these activities
can lead to serious injuries.
Stop heating
Stop the heating mode of the boiler with the on / off
switch
in the overview of the boiler. The boiler
emits a glowing charge and then switches to operating
mode [Switched off]. Then press the [De-ash]
key
to allow the boiler to perform a final ash removal.
WARNING!
Switch off the electricity to the boiler via the mains
switch
Switch off the electricity to the boiler via the mains
switch. This prevents injuries caused by switching
the boiler on inadvertently.
WARNING!
Burns caused by hot parts
Risk of burning on parts located behind the
boiler housing, even after shutting the boiler
down.
Allow the boiler to cool down sufficiently
before starting any activities.
2.6.2
Clean draught fan
Cleaning the draught fan
Unplug the draught fan's power supply. Loosen the
nuts and remove the draught fan.
Fig. 2-57: Draught fan
Remove the ash from the fan housing.
Fig. 2-58: Fan housing
Summary of Contents for ePE-K