4 Operation of the ELC
page 38
ELC X-Series-V1.5-06.18-GB
subject to technical alterations
1. Display
Press < 5sec
Shortly press the SET-button to get the lamp
operation data.
Lamp operation data on display:
[Actual Power]: actual power in Watts
[Power Set Value]: required power in Watts
2. Register [Lamp Status]
BUS-input-data (ELC
→
Master)
Byte-
No.
0 1 2 3
4
5
6
7
8
9
10 11 12 13 14
15
Name [ELC
Serial
Number]
[Software
Version]
[ELC
Nominal
Power]
[Error
Register]
[Warning
Register]
[Lamp
Status]
[Actual
Power]
[Actual
Voltage]
[Actual
Current]
[Reserved]
↓
Bit
7
6
5
4
3
2
1
0
Name n/a n/a n/a n/a n/a Lamp
Ignition
Run
Up
Lamp
On
Bits in use in register [Lamp Status]:
Bit 2 {Lamp Ignition}: during the ignition phase of the lamp the ”ignition“ bit is set (value =
1, otherwise 0).
Bit 1 {Run Up}: during warm-up of the lamp the “run-up“-bit is set (value = 1, otherwise 0).
Bit 0 {Lamp On}: as soon as the lamp has reached the required power and lamp voltage is
in a steady state, the ”lamp-on“-bit will be set (value = 1, otherwise 0).
Further operation data of the continuous operation state may be read out from the registers
[Actual Power], [Actual Voltage] and [Actual Current]:
[Actual Power] returns the actual power in Watts.
[Actual Voltage] gives account of the actual lamp voltage in Volts.
[Actual Current] contains the actual current in Ampère*10 with an accuracy of 100 mA
(e.g.: [Actual Current] = 12 means 1.2 A).
ELC ready
Bus connected 19h
PLamp: 5200 W
PSet: 5200 W