background image

www.etsolar.com

Subject to technical modifications without notice.   2016 © ET Solar Group

www.etsolar.com

Subject to technical modifications without notice.   2016 © ET Solar Group

12

13

www.etsolar.com

There are other options in addition to using a wiring type junction box only consisting of 
two terminals marked with "+" and "-" to represent the positive and negative terminals of 
the power supply. Some junction boxes include three or more terminals. Only those 
terminals indicated with "+" and "-" should be connected to the load. The others are 
designed for the bypass diodes to reduce the damage to modules caused by hot spots 
and to ensure undisrupted electrical energy output from the array. The hex nut in the exit 
position on the junction box is used to hold a rubber ring to seal the box.

When disconnecting the connectors of a photovoltaic module in a module array that is 
exposed to sunlight, electric arcs may result. Such arcs may cause burns and fires. 
Therefore, PV system commissioning and maintenance must be performed by a qualified 
electrician in accordance with the NEC.  Before disconnecting a module in a solar array, 
disconnect the string of module from the DC Disconnect at the inverter side, and then 
fully cover the module with an opaque material. Do not short the positive and the 
negative connectors of a module exposed to sunlight. 

The specification of wire for the electric coupler that ET Solar provides is 1 x 4.0mm². 
Equivalent wire should be used if the user prefers to use his own wire. When the module’ s 
rated current is lower, 12AWG wire is recommended for use, and the strength of the wire 
should be taken into consideration. ET Solar does not provide any output wiring for 
module installation. 

The modules will generate electrical energy under sunlight and otherlight sources.
Refer to Section 690-8 of the National Electrical Code for an additional multiplying factor 
of 125 percent (80 percent derating) which may be applicable.

ET Solar modules are designed to use copper wire only. The Wiring used is UL listed, 
rated 1000 V/600V, temperature rating 90 ° C ,wet or dry, Sunlight Resistant, 12 AWG, Type 
PV Wire.

The installation in Canada shall be in accordance with CSA C22.1, Safety standard for 
electrical installations,Canadian Electrical Code, Part 1.

WARNING! 

Wiring must only be completed by a qualified engineer with suitabletools.

The open-circuit voltage (Voc), short-circuit current (Isc) and maximal power (Pmax) are 
printed on the PET label on the backside of the module. The electrical characteristics are 
within ±10 percent of the indicated values of Isc, Voc and Pmax under standard 
test  conditions (irradiance of 100 mW/cm², AM1.5 spectrum, and a cell temperature of   
25°C (77°F)).
Under normal conditions, a photovoltaic module is likely to experience conditions that 
produce more current and/or voltage than reported at standard test conditions. 
Accordingly, the values of Isc and Voc marked on this module should be multiplied by a 
factor of 1.25 when determining component voltage ratings, conductor capacities, fuse 
sizes, and size of controls connected to the PV output. If modules are to be installed in 
parallel (electrically), each module (or series string of modules so connected) shall be 
provided with the maximum series fuse as specified.

3.4 Output Voltage, Current and Maximum Power

WARNING! 

In order to avoid electric shock and scalding, it is necessary to cover the surface of the 
module with a suitable material to prevent incidental light contacting the modules 
during the connection process.

Summary of Contents for ET-M536 series

Page 1: ...r modules If you have any further questions your dealer and ET Solar will gladly assist you Subject to technical modi cations without notice 2016 ET Solar Group Tel 86 25 86898096 86898098 Fax 86 25 8...

Page 2: ...ent solar cells and a behind the membrane multi layer backsheet These elements are laminated into a plate by being heated in a vacuum After installing the aluminum alloy frame and wiring compartment a...

Page 3: ...n the local wind and snow loads additional module clamps may be required e g if the combined wind and snow load is as high as 5400pa please use eight clamps When installing the modules the face of the...

Page 4: ...agram covering the entire grounding area We recommend fluorocarbon varnish For mounting system with bolts refer to picture 1 and 2 For photovoltaic systems to be installed near the coastline we recomm...

Page 5: ...e instructions strictly personal protective equipment such as goggle mask gloves etc may be needed during the operation No photovoltaic module should be installed within 50 meters from the edge of the...

Page 6: ...O type GBL 4DBT installed to frame using stainless steel screw secured to hole opening by star washer flat washer split washer and nut All hardware used is stainless steel The starwasher is used to br...

Page 7: ...e of rain ET Solar provides a wiring type box When the integrated J box is adopted no tool is necessary for wiring Just connect the modules in series according to or You can complete complex series an...

Page 8: ...ot provide any output wiring for module installation The modules will generate electrical energy under sunlight and otherlight sources Refer to Section 690 8 of the National Electrical Code for an add...

Page 9: ...essed or implied ET Solar reserves the right to change the manual the product the specifications or product information sheets without prior notice The array consists of modules in series and parallel...

Page 10: ...9 22 360 ET M672365xx 48 22 9 77 39 38 9 27 365 ET M672370xx 48 45 9 88 39 70 9 32 370 ET Poly ET P636 series ET P636115xx 21 75 7 55 17 2 6 68 115 ET P636120xx 21 75 7 63 17 4 6 89 120 ET P636125xx 2...

Reviews: