Wiring the outputs
5.4. Wiring the outputs
5.4.1. Solenoid turnout drives
You may use any of the commercially available solenoid turnout
drives from the well-known manufacturers with the SwitchPilot 3
Plus. Figure 8 shows the wiring of a turnout at output 1.
a) The common wire from the two coils is connected to terminal
C.
b) Terminal Out A is connected to the wire for the diverging route.
c) Terminal Out B is connected to the wire for the straight route.
Should the turnout not be aligned as you intended after pressing
the respective button on your command station respectively con-
trol panel (diverging and straight route are reversed), please swap
the wires at terminals Out A and Out B.
The power consumption of PECO switch drives is so high that the
PECO operating mode must be set.
5.4.2. Daylight signals with incandescent lamps or LEDs
If you are using daylight signals with incandescent lamps (bulbs)
or LEDs (light-emitting diodes), the corresponding output must be
configured in the K84 mode (Bistable continuous operation).
Incandescent lamps, as shown in Figure 8, Output 2, may be di-
rectly connected to the SwitchPilot 3 Plus.
Figure 8: Wiring the outputs
R
For uncouplers:
K83 operation (momentary
operation) to adjust.
Example for output 8:
OUTPUT 8
MODE :K83
Time :Permanent
Zoom :Disabled