11
Programming table - List of most important CVs
CV
Name
Description
Range
Default
28
RailCom® Configuration
Settings for RailCom®
131
Bit
Description
Value
0
Channel 1 Address broadcast disabled
Channel 1 Address broadcast enabled
0
1
1
No data transmission allowed on Channel 2
Data transmission allowed on Channel 2
0
2
29
Configuration register
The most complex CV within the DCC standards.
This register contains important information, some of which are only relevant for DCC
operation.
14
Bit
Description
Value
0
Normal direction of travel
Reversed direction of travel
0
1
1
14 speed steps DCC
28 or 128 speed steps DCC
0
2
2
Disable analog operation
Enable analog operation
0
4
3
Disable RailCom®
Enable RailCom®
0
8
4
Motor characteristic through CV 2, 6, 5 (For LokSound 5 DCC only!)
Motor characteristic through CV 67 - 94 (always active on LokSound 5)
0
16
5
Short addresses (CV 1) in DCC mode
Long addresses (CV 17 + 18) in DCC mode
0
32
31
Index register H
Selection page for CV257-512
16
16
32
Index register L
election page for CV257-512
0,1,2,3
0