8.

 

A warning that wireless security is not enabled will be displayed. Press the Next button to continue. 

 
9.

 

All ESTeem 195Ed on the network must use the same RF bandwidth.  Set the RF Bandwidth to 5 MHz and press the Next button to 
continue. 

 
10.

 

All Model 195Eds on the network must be on the same radio channel, representing a particular frequency.  If a particular channel has 
not been assigned for use, leave the 195Ed at a default value of 5 (912 MHz) and press the Next button. 

 

Step 8 – Security Warning Screen 

 

 

Step 9 – Bandwidth Selection 

 

 

Step 10 – Set Radio Channel 

Summary of Contents for 195Ed

Page 1: ...e following procedure will provide an initial communication link between two or more Model 195 s for testing purposes All the example commands listed in this guide can be adjusted to fit your communication network Please consult the ESTeem Model 195Ed User s Manual for more details Unpack Contents Each node in your ESTeem Model 195Ed s network may have different hardware components based upon the ...

Page 2: ...or Reset Switch RS 232 Configuration RJ 45 10 100BaseT Ethernet Port Transmit LED Receive LED Status LED Power over Ethernet LED Aux Power LED RS 232 Data Port Second Ethernet Port Antenna Overview Antenna Connectors TNC Female RP Antenna Port A Single Receive Antenna Antenna Port B Dual Receive Antennas ...

Page 3: ...3 Begin Programming 1 Assemble the ESTeem Model 195Ed using the following Antenna Connections Leave Open Single Antenna Configuration Dual Antenna Configuration Power and Data Connection ...

Page 4: ...et sent with each 195Ed If the factory default address matches your network configuration please proceed to Using Setup otherwise continue to step 4 4 Install the ESTeem Discovery Utility The ESTeem Discovery Utility will allow you to configure the IP address on the Model 195Ed to match your network Install the Discovery Utility on your computer by inserting the Resource Disk in your CD drive Note...

Page 5: ...Model 195Ed will be displayed in the program by the Ethernet MAC address and Current IP Address Figure 3 Note The SSID and Mode of Operation will be adjusted later in the configuration Double click on the 195Ed you wish to program and the Configure IP Address window will be displayed Figure 4 Enter an IP address and Subnet Mask for the 195Ed that matches your network subnet and press the OK button...

Page 6: ...nter admin for both the username and password and press the OK button 2 Select Setup on the top menu 3 Press the drop down menu and select AP Bridge and press the Next button Step 1 Sign In Screen Step 3 Select AP Bridge ...

Page 7: ...t the DHCP services to NONE and press the Next button 5 Verify the IP address and netmask for the 195Ed listed as bridge device are correct press the Next button Step 4 Turn DHCP Off Step 5 Verify IP Address ...

Page 8: ...cation SSID The default SSID is ESTeem and we will use this for demonstration Enter the SSID as listed above and turn off the wireless security features by selecting the NO radial Press the Next button to continue Note It is recommended that security be used in all wireless applications This procedure will forgo the security configuration for brevity Please see the example applications and the sec...

Page 9: ... RF Bandwidth to 5 MHz and press the Next button to continue 10 All Model 195Eds on the network must be on the same radio channel representing a particular frequency If a particular channel has not been assigned for use leave the 195Ed at a default value of 5 912 MHz and press the Next button Step 8 Security Warning Screen Step 9 Bandwidth Selection Step 10 Set Radio Channel ...

Page 10: ...cate with in the Peer 1 MAC Addr field below Leave the Priority Path Cost settings at the default values Encryption Type to None and change the Enable Link radial to Enable and press the Create Repeater Peer button Press the Next button Step 11 Repeater Peer Configuration Example Addresses Name Serial Number IP Address Ethernet MAC WLAN MAC 195Ed We Are Programming E 14096 172 16 48 189 00 04 3f 0...

Page 11: ...save all the changes made and reboot The reboot time is approximately 1 minute to be ready for operation 13 Complete all steps in this Setup Programming section for the other Model 195Ed s you will be testing before moving on the Testing Communication section ...

Page 12: ...splayed showing the status of all ports and memory in the 195Ed Under the Wireless Status heading click on the View Peer Table Figure 5 The Peer Table will list all other 802 11b or 802 11g wireless activity seen by the 195Ed and how it is classified Find the opposite 195Ed in the Repeater Peers list and information such as signal strength in dBm and time speed of last data packet will be displaye...

Page 13: ... ESTeems is to conduct a Ping test to the opposite modem s IP address This will test all links in the Ethernet bridge Technical Support User s Manual and Technical Documentation http www esteem com E Mail Support Support esteem com Phone Support 8AM to 5PM PST Monday Friday 509 735 9092 ...

Reviews: