Normally the calibration lasts 3 to 5 seconds.
Step 2 Click
to run the roller.
Step 3 Place items at the entrance of the tunnel, and scanned images will be displayed
on the system interface as they pass through the tunnel.
Step 4 Turn off the software system.
1)
Click
to stop the roller, and then click
to go to the
homepage.
2)
Click Shutdown and then in the prompt box, click Yes. The system will
turn off within 60 seconds. After that, power to the device will be cut off
and the power indicator will switch off.
4.3
Working Status
Turned off: The Machine is not on and the power indicator is off.
Stopped: The Machine is on and the power indicator is on, but the roller is not
running.
Running: The Machine is on, the power indicator is on, and the electric roller is
running.
Scanning: The Machine is on, and both the power and X-ray indicators are on.
To extend the device service life, put the Machine in the stopped state if no items were
inspected for more than 30 minutes after startup. You can also install an automatic
sensor for convenient management.
5
Software System Operation
5.1
System Main Interface
The scanned images are displayed in the center of the main interface. As items pass
through the tunnel on the conveyor belt, the scanned images appear on the interface,
scrolling across it. The area under the scanned images can be divided into three sections.
Figure 5-1 System main interface