Care and Maintenance

IMPORTANT: We recommend cleaning your humidifier every two weeks.
Follow instructions. 

Humidifiers provide comfort by adding moisture to dry, heated indoor air. To get the most
benefit from the humidifier and to avoid product misuse, follow all instructions carefully,
specifically the operation and care and maintenance guidelines. Please note this is an electri-
cal appliance and requires careful attention when in use. 
In addition, if you do not follow the recommended care and maintenance guidelines, microor-
ganisms may be able to grow in the water within the humidifier’s reservoir. 

Caution: Disconnect power before cleaning or servicing unit. 
WARNING: It is very important that cleaning solutions, such as bleach, bacte-
ria treatment, or descaler which could be used to clean the cabinet are not
sprayed or applied to the chassis/power pack assembly. Additionally, do not
immerse the power pack in water or any other solution. These solutions can
cause a serious electrical malfunction of the humidifier. 

1) Turn unit off by turning humidistat completely counterclockwise. 
2) Unplug electrical cord from wall outlet.
3) Lift out water bottle.
4) Lift off chassis/power pack.
5) Carefully lift wick with rod and float assembly from cabinet, allowing any water to drain

from it into cabinet reservoir. Then remove float assembly from wick. 

REMOVING SCALE FROM THE CABINET

6) Remove any remaining water in the reservoir with a sponge. Fill the reservoir with one

gallon of fresh warm water and one 8-oz. cup of undiluted white vinegar. Let solution
stay 20 minutes. Clean all interior surfaces with soft brush. Dampen soft cloth with undi-
luted white vinegar and wipe out the reservoir to remove scale. 

7) Rinse the reservoir thoroughly with water to remove scale and cleaning solution before

disinfecting. 

DISINFECTING CABINET RESERVOIR

8) Fill the reservoir with a mixture of one teaspoon chlorine bleach and one gallon of fresh

warm water. Let solution stay 20 minutes, swishing every few minutes. Make sure the
cleaning solution does not come in contact with the chassis/power pack. Do not attempt
to pour liquid directly through the grille into the humidifier cabinet. 

9) Empty the reservoir after 20 minutes. Rinse with water until bleach smell is gone. Dry

with clean cloth or paper towel. 

10) Clean all surfaces of the chassis/power pack with a soft, dry cloth. DO NOT USE LIQ-

UID CLEANING SOLUTIONS, INCLUDING WATER, TO CLEAN THE CHASSIS/POWER
PACK. AN ELECTRIC SHOCK MAY RESULT OR THE HUMIDIFIER MAY BE DAMAGED. 

Summary of Contents for Bemis H10 400

Page 1: ...r OWNERS CARE USE MANUAL Models H10 400 Console Two Speed H12 001 Console Three Speed H12 300 Console Three Speed H12 400 Console Three Speed H12 600 Console Three Speed Easiest to Fill Easiest to Cle...

Page 2: ...It is very important that cleaning solutions and other liquids such as bleach which may be used to clean the cabinet are not sprayed or applied to the power pack chassis assembly These cleaning solut...

Page 3: ...hen fanned out into the room 1 Water bottle 2 Chassis Power Pack motor and fan assembly 3 Evaporative wick 4 Water reservoir 5 Dry room air intake 6 Moist air output 5 Locate your humidifier on an ins...

Page 4: ...nside back of the cabinet The white float must be positioned into the pocket in the bottom of the cabinet B AIR CLEANING FILTER OPTIONAL 7 The AirCare filter has four tangs C that engage into four key...

Page 5: ...et operation or a high setting for maximum output 13 All models have an automatic humidistat The humidistat will turn the humidifier on when the relative humidity in your home is below the humidistat...

Page 6: ...4 Lift off chassis power pack 5 Carefully lift wick with rod and float assembly from cabinet allowing any water to drain from it into cabinet reservoir Then remove float assembly from wick REMOVING SC...

Page 7: ...r Wicks guarantee the certified output of your humidifier Use of evaporative wicks other than Bemis by Essick Air evaporative wicks will void your warranty as well as the certification of output and m...

Page 8: ...Bacteria Treatment in Canada Controls bacteria growth in humidifiers and helps eliminate unpleasant odors Follow directions on bottle for proper application This solution should not be used to clean...

Page 9: ...may also have other rights which vary from state to state or province to province This warranty does not cover damage resulting from misuse or abuse of the humidifier accidents or alterations to the p...

Page 10: ...s velocidades H12 400 Consola tres velocidades H12 600 Consola tres velocidades El m s r pido de llenar El m s r pido de limpiar Configuraci n silenciosa para uso nocturno Arranque autom tico Interrup...

Page 11: ...midificadores y productos qu micos de marca Bemis by Essick Air Para ordenar piezas mechas vaporizadoras y productos qu micos llame al 1 800 547 3888 7 Se recomienda limpiar con regularidad Referirse...

Page 12: ...r la botella dentro del dep sito Luego que la botella se ha vaciado dentro del dep sito esta debe ser llenada nuevamente a fin de obtener el m ximo de tiempo de trabajo 3 Cuando se llena la botella y...

Page 13: ...cada v stago de rueda dentro de los cuatro agujeros para las ruedas en cada esquina del fondo del humidificador Las ruedas de agua deben calzar ajustadas y deben ser A insertadas hasta que el hombro d...

Page 14: ...ra de la botella de agua mire hacia el interior D Reemplace la cobertura negra de la botella de agua y esto completar el ensamblado No intente mover al humidificador lleno dado que el agua del dep sit...

Page 15: ...o Los filtros AirCare son opcionales y no son requeridos para una operaci n normal del humid ificador FILTRETE es marca registrada de 3M Corp Cuidado y Mantenimiento IMPORTANTE Recomendamos limpiar el...

Page 16: ...sta que el olor al cloro se haya disipado Secar con trapo limpio o tohalla de papel 10 Limpiar todas las superficies de la fuente alimentadora chassis con un trapo suave y seco NO USAR SOLUCIONES LIMP...

Page 17: ...otante Almacenamiento en verano Secar la unidad antes del almacenaje desenchufar el cord n quitar y vaciar la botella de agua quitar la fuente de poder y usar broches de la ropa para asegurar el ancho...

Page 18: ...1970CN 32 Onzas aprox 900 ml Controla el desarrollo de bacterias en los humidificadores y ayuda a elimi nar olores desagradables Seguir las indicaciones de la botella para su apli caci n adecuada Est...

Page 19: ...var an de un estado a otro y de una provincia a otra Esta garant a no cubre los da os ocasionados por mal uso o abuso del humidificador accidentes o alteraciones al producto uso comercial o da o duran...

Page 20: ...tesses H12 300 Console trois vitesses H12 400 Console trois vitesses H12 600 Console trois vitesses Plus facile remplir Plus facile nettoyer Mode silencieux pour la nuit Hygrostat automatique Arr t au...

Page 21: ...our maintenir cette classification UL voir le centre de service de la r gion pour toute r paration 5 Pour maintenir la valeur nominale certifi e n utiliser que les produits chimiques et les fil tres m...

Page 22: ...eur s arr te automatiquement et se remet automatiquement en marche une fois la bouteille d eau et le r servoir remplis 2 Au premier remplissage de la bouteille d eau la m che est s che cela prend envi...

Page 23: ...optionnel Vendu comme accessoire Assemblage DES ROULETTES A 4 Retourner le meuble de l humidificateur vide l envers Ins rer une tige de roue dans chacun des quatre orifices situ s aux quatres coins de...

Page 24: ...capuchon du clapet vers le bas afin que la rainure de la bouteille d eau soit dirig e vers l int rieur D Remettre le couvercle noire de la bouteille d eau pour compl ter l assemblage Ne pas tenter de...

Page 25: ...si re le pollen et les particules polluantes dans l air Il est suivi de la deuxi me tape d humidification qui consiste en un m dia au charbon activ qui absorbe les odeurs laiss es par la cuisson les a...

Page 26: ...r toutes les surfaces internes l aide d une brosse poils souples Mouiller un chiffon doux en utilisant le vinaigre blanc non dilu et essuyer le r servoir pour enlever le calcaire 7 Rincer le r servoir...

Page 27: ...ie de l humidificateur 19 REMARQUE Lors du remplacement de la m che la retenue de la tige du flotteur doit tre tir e avant l insertion de la tige du flotteur Entreposage lors de la saison estivale Pou...

Page 28: ...la croissance des bact ries dans les humidificateurs et favorise l limination des odeurs d sagr ables Suivre les directives sur la bouteille pour une application appropri e Cette solution ne doit pas...

Page 29: ...d une province l autre Cette garantie ne couvre pas les dommages caus s par une mauvaise utilisation un emploi abusif un accident ou des modifications port es sur le produit une utilisation commercial...

Page 30: ...Essick Air Products 5800 Murray Street Little Rock AR 72209 501 562 1094...

Reviews: