Manual   Override   Bypass   

The   Manual   Override   push   to   exit   timing   may   be   adjusted   from   approximately   half   a   second   to   sixty   seconds.      This   function   is   
designed   to   be   used   if   the   microwave   radar   sensor   becomes   non-­‐functional,   to   allow   exiting   through   an   emergency   egress   door.      
This   is   internally   configured   as   a   “failsafe”   function,   the   locking   mechanism   should   also   release   when   the   power   fails   to   the   switch.      
Manual   override   operates   a   second   relay   controlled   by   a   timer   circuit,   that   is   normally   energized,   so   that   if   power   fails   this   relay   
will   activate   the   locking   mechanism,   (in   fail   secure),   or   release   the   locking   mechanism,   (in   fail   safe).   

Mounting   
HEWMO-­‐1

   is   designed   for   narrow   or   mullion   mount   applications.   For   recessed   installation,   use   template   provided   to   mark   

and   remove   material.   For   surface   mount   installation,   an   optional   spacer   ring   is   available.      

HEWMO-­‐2   

is   designed   to   mount   to   a   standard   U.S.   Single   Gang   switchbox.      An   optional   back   box   (BAK   BOX-­‐SGS)   is   available   

for   surface   mount   installation.   

HEWMO-­‐3

   is   designed   to   mount   to   a   standard   U.S.   Double   Gang   switch   box.   

TYPICAL   INSTALLATIONS   

There   are   two   sets   of   relay   contacts   that   may   be   used,   each   of   which   is   routed   through   the   manual   override.      The   normally   closed   
contacts,   the   white   wire   to   the   yellow   wire,   would   be   in   series   with   a   normally   powered   locking   mechanism,   such   as   a   magnetic   
door   lock.      This   would   also   be   in   series   with   the   controller   applying   locking   power.      The   normally   open   contacts,   the   orange   to   the   
blue   wires,   could   be   used   to   apply   a   “request   to   exit”   or   “REX”   signal   to   the   controller,   which   would   then   apply   power   to   unlock.      
Since   both   sets   of   contacts   are   not   normally   used   at   the   same   installation,   the   set   that   is   not   being   used   as   described   may   be   used   
to   indicate   that   the   HEW   has   been   activated   to   a   control   panel   or   security   system.   

Regulatory   Compliance   -­‐   FCC   

End   Product   Labeling   

The   next   assembly   should   have   instructions   and   a   label   that   refers   to   the   manufacturer   FCC   ID:   UXS-­‐IPM165      &   Canada   IC:   6902A-­‐IPM165   for   all   
models   of   the   Hand-­‐E-­‐Wave.      
This   device   HEW   has   been   tested   and   approved   to   be   compliant   with   Part   15.245   of   the   FCC   Rules   and   with   RSS-­‐210   Issue   7   of   Industry   
Canada.   Operation   is   subject   to   the   following   conditions:   

1.

 

This   device   may   not   cause   harmful   interferences,   and   

2.

 

This   device   must   accept   any   interference   received,   including   interference   that   may   cause   undesired   operation.   

This   equipment   has   been   tested   and   found   to   comply   with   the   limits   for   a   Class   B   digital   device,   pursuant   to   part   15   of   the   FCC   Rules.      These   

limits   are   designed   to   provide   reasonable   protection   against   harmful   interference   in   a   residential   installation.      This   equipment   generates,   uses   
and   can   radiate   radio   frequency   energy   and,   if   not   installed   and   used   in   accordance   with   the   instructions,   may   cause   harmful   interference   to   
radio   communications.      However,   there   is   no   guarantee   that   interference   will   not   occur   in   a   particular   installation.      If   this   equipment   does   cause   
harmful   interference   to   radio   or   television   reception,   which   can   be   determined   by   turning   the   equipment   on   and   off,   the   user   is   encouraged   to   
correct   the   interference   by   one   or   more   of   the   following   measures:   

 

Reorient   or   relocate   the   receiving   antenna   

 

Increase   the   separation   between   the   equipment   and   receiver   

 

Connect   the   equipment   into   an   outlet   on   a   circuit   different   from   that   to   which   the   receiver   is   connected   

 

Consult   the   dealer   or   and   experienced   radio/TV   technician   for   help   