installation
48
installation
49
V.1.0
V.1.0
Hose
Duct
Maximum length
4 m
5 m
One 45° elbow connector
- 1 m
- 0.3 m
One 90° elbow connector
-1.8 m
- 0.6 m
One short 90° elbow connector
- 2.7 m
One bulkhead connector
- 2 m
- 2 m
Each elbow connector and other passages must be subtracted from the maximum length
mentioned above.
−
Ventilation hose connector:
1.
Connect the air ventilation hose to
the hose clamping piece by turning
it anti-clockwise.
2.
Organise the pipe passages as
shown in the adjacent figure.
•
Humid air from the dryer released
into the room can cause issues. It can damage the walls and furniture in the room.
•
The ventilation hose can be brought outside through a window or connected to the air
exhaust duct in the bathroom.
•
The air exhaust duct must be brought directly outside. A minimum number of elbow
connectors should be used to avoid impeding air circulation.
•
To prevent water from accumulating in the hose, make sure that the hose is not bent at
ground level.
The ventilation hose must not be connected to the exhaust duct of a stove or
chimney.
Do not operate your dryer at the same time as heating appliances such as
coal or gas stoves. The air flow could cause the exhaust duct to explode.
!
Adjusting the feet
Your appliance must be stable, horizontal and level to ensure
silent operation without vibration. Adjust the front feet to level
the dryer.
1.
Manually loosen the feet.
2.
Adjust the feet until the appliance is level and balanced.
•
Do not use any tools to unscrew the adjustable feet as you
may damage them.
•
Never unscrew the adjustable feet from their housing.
Electrical connection
Your appliance can only be connected to a wall outlet powered by single phase 230 V ~ 50 Hz.
Before plugging your dryer in, make sure that your home’s mains voltage matches that
specified on the dryer’s data plate and that the mains plug is correct for the wall socket.
−
Earthing
•
This appliance is equipped with an earthed mains plug.
•
It must be plugged into a wall socket with a properly installed earth that is connected to the
electricity network in accordance with the applicable standards.
•
It is imperative for this power cord to remain accessible after installation.
•
WARNING: Risk of electric shock if the earth is not connected correctly.
In the event of a short circuit, the earth connection reduces the risk of electric
shock by providing a route to earth for the current to take.
•
If you have any questions about earthing or the electrical connection, please consult a
qualified person.
•
We cannot be held responsible in the event of accidents or incidents caused by a non-
existent or defective earthing.
•
If the power cord is damaged, it must be replaced by your dealer, the customer
service department or a similarly qualified person to prevent harm.
•
Never use with an extension cord to connect the appliance.
•
If your home's fuse or circuit breaker is less than 16 amps, have a qualified electrician
install a 16-amp fuse.
Summary of Contents for 0008007957
Page 83: ......