WARNING THIS APPLIANCE MUST BE EARTHED

 

IMPORTANT 

The wires in the mains lead are coloured in accordance with the following code. 

 

Green and yellow: 

EARTH 

Blue: 

NEUTRAL 

Red: 

LIVE 

As the colours of the wires in the mains lead of this appliance may not correspond with the colour markings in your plug proceed as 

follows: - 

 

The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the 

letter E, or coloured green or coloured green and yellow, or marked with the earth symbol   

 

The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N, or 

coloured black. 

 

The wire which is coloured brown must be connected to the terminal in the plug which is marked with the letter L, 

or coloured red. 

 

3.

 

Operating the Stove 

The Little Atom’s controls are located at the back of the stove towards the top right hand corner.   

 

The

 

on/off switch is marked with 

I/O

 and will need to be switched to 

I

 to illuminate the flame effect.    

 

The flame effect has to be illuminated for the heater to work.  For heating the controls are located next to the on/off 
switch.  For 1kw of heat push in the switch marked with a single bar 

I

.  For 2kw of heat push in the switch marked 

with the double bars

 

II

.

  Both switches have to be depressed for 2kw of heat. The thermostat should be switched to 

maximum. Once the required room temperature is achieved turn the thermostat towards minimum until you hear a 

click. The thermostat will then regulate the room temperature automatically. 

 

Thermostat information: 

There can be up to a 2 or 3 degrees drop or rise in temperature for the thermostat to activate or 

deactivate.  The temperature is taken from around the stove unlike a wall thermostat that is usually positioned around the 

middle of a room, so please allow for inaccuracies.  Situations such as room size or position of fireplace i.e. near a working 

radiator might cause the thermostat not to work efficiently.  

 

Safety concerns:

 Areas around the stove will become hot when the heater is activated.  We strongly recommend small 

children be kept away from having any direct contact with the appliance by means of fitting a fireguard.  This appliance is not 

intended for use by persons (or children) with reduced physical sensory or mental capabilities or lack of experience or 

knowledge unless they have been given supervision or instruction concerning the use of the appliance by the person 

responsible for their safety.   Children should be supervised to ensure they do not play with this appliance.  

 

Heater thermal cut out:

  The heater is fitted with a thermal cut out to prevent any damage due to overheating. The element 

will continually and automatically cut out if the airflow is obstructed. 

Never

 cover the air outlets.  To reset the thermal cut 

out, switch the stove off, disconnect from the mains supply, remove the cause of overheating and allowed to cool for a 

suitable period then switch the stove back on. Caution: In order to avoid a hazard due to inadvertent resetting of the thermal 

cut out, the appliance must not be supplied through an external switching device, such as a timer, or connected to circuit 

regularly switched on and off by a utility.    

 

4.

 

Maintenance 

Before any maintenance/cleaning is undertaken always disconnect the stove from the mains power supply.  Be aware of any sharp edges due to 

exposed steel work or plastics. 

 

       

 4.1. Replacing the fuel effect lamps 

Your Stove uses two 7w E14 LED lamps to illuminate its fuel effect.  Replacement lamps are available from Flamerite Fires and its 

stockists (see top of page 1).  Please note that replacement lamps are not covered under warranty. 

 

Unscrew the door handle by applying pressure and turning anti-clockwise; open the door (will not open fully). 

 

Remove the fuel effect and the two orange fuel beds.  A hole will be visible to allow a thin electrical screwdriver to be insert 

enabling the base fuel bed to be removed. 

 

Unscrew the lamp and replace. 

 

Replace the orange fuel bed and fuel effect.  

See section 2.3 & 2.4 under installation.

 

 

Summary of Contents for Little Atom

Page 1: ... the Stove Your Stove has primarily been designed for use as part of a fireplace suite although it may be used freestanding Due to its weight The Little Atom comes with its cast iron top and door packed separately so it may be better manoeuvred into position If using in conjunction with one of our Fireplace suites a piece of glass is also supplied which should be placed on the hearth for the stove...

Page 2: ...ts rear these will line up with corresponding holes on the very top of the stove Gently place the cast top on the stove Fig 8 Fig 7 Fig 8 2 6 Fitting Optional Stove Flue Pipe An optional flue pipe is available and may be used with the 150mm deeper stove insert Quite simply place the round block supplied with the flue pipe magnets facing down into the recess on the cast top Next place the flue pipe...

Page 3: ...or might cause the thermostat not to work efficiently Safety concerns Areas around the stove will become hot when the heater is activated We strongly recommend small children be kept away from having any direct contact with the appliance by means of fitting a fireguard This appliance is not intended for use by persons or children with reduced physical sensory or mental capabilities or lack of expe...

Page 4: ...remove dust from around or on the impellor 5 Warnings Do not use the stove in the vicinity of a bath shower or swimming pool Never use the stove to dry laundry Never install the stove directly underneath a fixed main socket Never cover the appliance during the operation of the stove The use of an extension lead is not recommended Particular caution should be applied to ensure that children do not ...

Page 5: ...m heat output indicative Pmin 1 kW Maximum continuous heat output Pmax c 2 kW Auxiliary electricity consumption At nominal heat elmax 29 W At minimum heat elmin 29 W In standby elSB 0 kW Type of heat output room temperature control With mechanical thermostat room temperature control Yes Contact details Flamerite Fires Ltd Greenhough Road Lichfield Staffs WS13 7AU ...

Reviews: