background image

Setting Up the Bed Sensor 

 

 

Care@Home™ Bed Sensor User Guide 

 

Control Panel Response 

Meaning 

Low pitch beep and 

EMERGENCY

 button ring lights 

blue as 

EMERGENCY

 button 

lights red. 

This bed sensor has already been paired with 
this control panel. 

Beeps and the 

EMERGENCY

 

button ring lights red 

Bed sensor cannot be paired. Control panel 
memory is full.  

8.

 

Attach the mounting base to the transmitter. The LED lights red.  

 

2.3.

 

Placing the Bed Sensor 

Proper placement of the bed sensor is important for accurate detection and the resident's comfort.  

 

 

The pressure pad should be placed in the resident's bed: 

 

On top of the mattress 

 

Covered by a sheet 

 

At the approximate location of the resident's waist/buttocks 

 

With the cable on the side not used for getting in and out of bed 

 

Place the transmitter out of the resident's way, for example: 

 

Under the mattress 

 

Between the bedframe and the mattress 

Transmitter  

Pressure pad 

Summary of Contents for Care@Home ES700BD

Page 1: ...Care Home Bed Sensor User Guide ESUGSC104 Version 1 0 February 2019...

Page 2: ...Bed Sensor 4 2 1 Required Items 4 2 2 Pairing the Bed Sensor 4 2 3 Placing the Bed Sensor 6 2 4 Associating the Bed Sensor with a Motion Detector 7 3 Operating the Bed Sensor 8 3 1 LED Indications 8...

Page 3: ...ireless sensor for detecting the resident s presence in bed Care Home uses the bed sensor together with an associated motion detector PIR to determine if the resident is in the bedroom The bed sensor...

Page 4: ...ed sensor with a motion detector 2 1 Required Items Ensure you have the following One 3 V CR123A lithium battery A flat headed screwdriver 2 2 Pairing the Bed Sensor You need to pair the bed sensor wi...

Page 5: ...damage if it is installed incorrectly 6 Continue to hold the tamper switch until the control panel responds 7 Ensure that pairing was successful based on the response you receive from the control pane...

Page 6: ...h the mounting base to the transmitter The LED lights red 2 3 Placing the Bed Sensor Proper placement of the bed sensor is important for accurate detection and the resident s comfort The pressure pad...

Page 7: ...te a bed sensor with a motion detector using the Care Home web application 1 Log on to the Care Home web application 2 Click Users A list of users appears 3 Click the name of the resident The Resident...

Page 8: ...nds notifications to the control panel for the following events Pressure is applied to the pad Pressure is released from the pad The battery is low The tamper switch is activated 3 3 Supervision The b...

Page 9: ...ry 1 Insert a screwdriver into the transmitter s slot and press the tab to release the mounting base 2 Remove the old battery 3 Press the tamper switch several times 4 Insert the new battery observing...

Page 10: ...curity 32 bit ID over 4 billion combinations Transmitter Security Tamper mechanism for open cover Sensitivity Nominal detection threshold 22 kg 50 lbs Power Consumption Batteries 3V CR123A lithium bat...

Page 11: ...you some or all of the above disclaimers exclusions or limitations may not apply to you By using the information contained herein you agree that the laws of the State of Israel without regard to princ...

Reviews: