Page 24
PLUS-500-I03-160617
Automatic Safety Shut Off
If the power level is not changed during a pre-set time, the
corresponding heater turns off automatically. The maximum time a
heater can stay on, depends on the selected cooking level
Power Level
Maximum Time ON (hours)
1
10
2
10
3
10
4
10
5
10
6
10
7
10
8
10
9
3
Operating the timer
The timer value can be selected between 1 and 99 minutes. It is possible
for the user to time all the heaters at the same time at any power level
(1...P).
To activate a timer for any heater, first of all this heater must be
selected (touch the HEATER SELECTION key). Then, using + or - keys a
power level must be decided (for example power level 2).
Timer option is not operational if power level value is ‘0’.
When required power level is selected, touching again HEATER
SELECTION key, a beep sounds and a letter T with a dot point appears on
the heater display. The remaining time will be displayed in the opposite
part of timed heater. If timed heater is in the down part, timed time will
appear in up displays and vice-verse.