THIS APPLIANCE MUST BE COMMISSIONED BY A OFTEC REGISTERED ENGINEER

THE WARRANTY CARD MUST BE RETURNED TO ENSURE GUARANTEE VALIDITY

Ouzledale Foundry Co. Limited, Long Ing, Barnoldswick, Lancashire BB18 6BN

Tel: 01282 813235 Fax: 01282 816876 Email: [email protected] Website: http://www.esse.com

T H E A U T H E N T I C O R I G I N A L

1. BOILER BURNER

ECOFLAM PART NO

A. COMMON PARTS

Mounting Gasket

18.04.2001

Oil Pump

Danfoss BFP 11R3

02.02.0002

Flexible Oil Line

740mm –

1

/

4

BSP Braided

01.02.3002

Control Box

Landis and GYR LOA 24

04.03.1013

Photocell

Landis & GYR QRB1

04.03.3007

B. 0-106 BURNER

Nozzle

1.0 x 80ES

2021-258

Flame Tube

BFB 01.153/002

01.01.1002

C. 0-80 BURNER

Nozzle

0.75 x 80ES

2021-256

Flame Tube

BFB 01.002/002

01.01.1001

D. 0-60 BURNER

Nozzle

0.6 x 80ES

2021-254

Flame Tube

BFB 01.104

01.01.1010

2. COOKER BURNER

Nozzle

Danfoss 0.3 x 80ºH or Delavan

02.02.1150

0.3 80ºA

Flame Tube

BFB 01.016/002

01.01.1020

Oil Pump

Danfoss BFP 21 R3

02.02.0202

Flexible Oil Line

740mm –

1

/

4

BSP Braided

01.02.3002

Control Box

Landis & GYR LOA 24

04.03.1013

Photocell

Landis & GYR QRB 1S

04.03.3011

3. THERMOSTATS

ESSE PART NO

Boiler Thermostat

Altecnic 540095

CENT 081 BO

Boiler Limit Stat

Altecnic 541510

2040-640

Cooker Thermostat

Anglo Nordic 1300608

2040-636

Cooker Limit Stat

Altecnic 541887

CENT 082 BO

Neon Light

2040-645 BO

Control Knob Cooker

Altecnic

2023-384 BO

Control Knob Boiler

Altecnic

2040-200 BO

When ordering replacement parts, quote the cooker serial number and type.

REPLACEMENT PARTS

OIL FIRED COOKERS & BOILERS

INSTALLATION & COMMISSIONING INSTRUCTIONS

MODELS: OC, O-60, O-80 & O-106

09/07

Summary of Contents for O-106

Page 1: ...lame Tube BFB 01 002 002 01 01 1001 D 0 60 BURNER Nozzle 0 6 x 80ES 2021 254 Flame Tube BFB 01 104 01 01 1010 2 COOKER BURNER Nozzle Danfoss 0 3 x 80 H or Delavan 02 02 1150 0 3 80 A Flame Tube BFB 01...

Page 2: ...0 1 O 60 OC 36 000 Btu h 80 A or H 87 1 notch 4 5 O 106 170 4 41 O 80 130 3 62 O 60 100 2 96 MODEL AIR SUPPLY MIN TOTAL FUEL CONSUMP CM 2 l h MODEL OUTPUT INPUT Nozzle Pressure Fuel Air C02 Soot No kW...

Page 3: ...e fitted to the programmer Commission the programmer as described in figs 3a 3b Typical systems are shown in Figs 4 5 5A 6 6A The water system and the electrical wiring system used must be in accordan...

Page 4: ...em can allow the boiler and pump to operate on bypass only the bypass must be placed at least 1 5m 5 3 away from the boiler Inhibitor Attention is drawn to the current issue of BS5449 and BS 7593 on t...

Page 5: ...is firing check and if necessary adjust oil pressure see Technical Data Carry out combustion checks by inserting probe into sampling point provided at the flue box Fig 8 The air setting is pre set at...

Page 6: ...CentaurPlus controls are fitted with battery reserve which maintains programmed times in the event of a mains power failure Battery Reserve The battery must be commissioned prior to fitting the contr...

Page 7: ...L Boiler stat Boiler burner Cooker programmer Cylinder stat L641A or equivalent DHWS Cylinder primary motorised valve 28mm V4043H or equivalent Heating circuit motorised valve V4043H or equivalent Roo...

Page 8: ...1 L N E HORSTMANN C17 Model OC COOKER ONLY Fig 6a Boiler stat Boiler burner Cooker programmer Cylinder stat L641A or equivalent DHWS Cylinder primary motorised valve 28mm V4043H or equivalent Heating...

Page 9: ...nce overheat device has operated Control relay or photo cell defective Burner fails to start Lamp not lit Oil not being delivered Excess flue draught is preventing flame establishment No spark Burner...

Page 10: ...Tel No Fax No OFTEC Reg No Engineers Name Date Address Tel No Fax No OFTEC Reg No Engineers Name Date Address Tel No Fax No OFTEC Reg No 18 Engineers Name Date Address Tel No Fax No OFTEC Reg No Engin...

Reviews: