Page 17
200-XK-I06-201217
One of the top baffle bricks can be removed and the remainder spaced
evenly to help deal with a poor flue draught. This is designed to be a
temporary measure as it will affect the efficiency of your stove.
RE-FUELLING ON TO A LOW FIRE BED
If there is insufficient burning material in the fire bed to light a new fuel charge,
excessive smoke emission can occur. Refuelling must be carried out onto a sufficient
quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable
period. If there are too few embers in the fire bed, add suitable kindling to prevent
excessive smoke.
FUEL OVERLOADING
The maximum amount of fuel specified in this manual should not be exceeded,
overloading can cause excess smoke.
OPERATION WITH DOOR LEFT OPEN
Operation with the door open can cause excess smoke. The appliance must not be
operated with the appliance door left open except as directed in the instructions.
DAMPERS LEFT OPEN
Operation with the air controls or appliance dampers open can cause excess smoke. The
appliance must not be operated with air controls, appliance dampers or door left open
except as directed in the instructions
.
WOOD BURNING
LIGHTING & CONTROLLING THE FIRE
Front of the stove
Rear of the stove
Top Baffle Bricks