PROGRAMMING
Page 14
ADVANCED PROGRAMMING
CALL CYCLES
FOR EMERGENCY
CALLS
(INST)
(cycles, from
0
to 9; 0 = unlimited)
AUTOMATIC
ANSWER
(INST)
(ring number from 0 to 9; 0 = disabled;
factory default
1
)
CONNECTION
TIME AFTER
AUTOMATIC
ANSWER
(INST)
(minutes, from
1
to 9)
OFFSET FLOOR
MESSAGES
(INST)
(offset, from
0
to 9)
RELAY SETTINGS
(with optional
board)
(INST)
RELAY 1
same behavior as output AI
same behavior as output AR
active for mains failure
RELAY 2
door opener
active as long as the emergency alarm
progresses
active as long as the buttons are pressed
RELAY
INTERMITTENCE
(INST)
relay 1: steady-state / relay 2: steady-state
relay 1: intermittent / relay 2: steady-state
relay 1: steady-state / relay 2 intermittent
relay 1: intermittent / relay 2: intermittent
DTMF
GENERATOR
SETTINGS WITH
GSM200-C
(INST)
DTMF generated by mobile network
DTMF generated by ST56
(DTMF duration = X * 50ms)
READING
GSM200-C
SIGNAL LEVEL
(INST)
Listened or read digits
Quality
0-12
No signal
13-18
Low signal
19-24
Medium signal
>24
High signal