PROGRAMMING 

Page 17  

Advanced programming 

ADVANCED PROGRAMMING 

CHANGE THE 
INSTALLER 
PASSWORD “0” 
(INST) 

 

 [

]  

   (old) 

..

 [

]  

..

 [

 (new)            (new)

 

CHANGE THE 
OPERATOR 
PASSWORD “1” 
(INST) 

 

 [

]  

     (old)

 

..

 [

]  

..

 [

  (new)            (new)

 

INPUTS 
NORMALLY 
OPEN/CLOSED 
(INST) 

 

  

input  
(2=AL2  
3=IN1) 

  

type  
(0=normally closed 

1=normally open

 

 
 
 
 
 
 
 
 
 
INPUTS PRESET 

*

  

(INST) 
 
 
 
 
 

*

 

for the complete 

configuration of the 
inputs, please refer 
to the Expert 
Programming Guide

 

 

 AL2=alarm input / IN1=filter input 

 AL2=auxiliary input / IN1=filter input 

 

AL2=alarm input / IN1=gong input

 

 AL2=auxiliary input / IN1=gong input

 

 

AL2=reset input / IN1=filter input 

 AL2=reset input / IN1=gong input

 

 AL2=reset input / IN1=alarm input

 

 

AL2=reset input / IN1=auxiliary input

 

 AL2=alarm input / IN1=alarm input 

in listening mode the value 9 indicates inputs set with 
the code 390 

Summary of Contents for HELPY COMPACT-Q

Page 1: ...Alarm system for elevators compliant with the European Standard EN 81 28 2018 HELPY COMPACT Q QUICK GUIDE To download User guides in other languages please scan the QR code or visit https www esse ti it en manuals ...

Page 2: ... F Received alarm indicator light G Pushbutton connection cable connect to T H Micro SD Card slot I Jumpers J16 J17 L Connector not used M Given alarm indicator light N Terminal blocks O Wiring exit slot P Built in microphone Q Crosshead screw for cover fixing R Built in loudspeaker connection cable connect to A S Built in loudspeaker T Pushbutton connection cable connect to G U Microphone hole To...

Page 3: ...eived alarm indicator light 12 Vdc or 0 Vdc via jumper J17 12 12 Vdc output max 100 mA C Common terminal for inputs AL1 and IN1 Negative AL1 Alarm input 1 1 AL2 Reset input 2 2 freely programmable IN1 Filter input 2 freely programmable ALT2 Output for connecting loudspeaker of passive speaker unit top or bottom of elevator car MIC2 Input for connecting microphone of passive speaker unit or single ...

Page 4: ... Helpy Compact Q up to 2 passive speaker units or cables with microphone on top and bottom of elevator car Make the connections as shown in the table below TERMINAL BLOCKS HELPY COMPACT Q TERMINAL BLOCKS MAX DISTANCE PASSIVE SPEAKER UNIT A ALT2 6 m with shielded cable B MIC2 or MIC3 CABLE WITH MICROPHONE red wire MIC2 or MIC3 cable length 3 m white wire ...

Page 5: ...O The pushbuttons of pit top and bottom of elevator car can only be connected to AL2 terminal block if they are voltage free Note the reset input AL2 must be configured as alarm input with the Inputs setting programming codes 390 or 55 Note the AL2 input can be configured as NO or NC with the Inputs normally open closed programming code 41 Connect following the diagram shown below the external pus...

Page 6: ...TING THE FILTER INPUT It is possible to use a voltage free contact NO or NC Connect following the diagram shown below the filter contact Note the IN1 input can be configured as NO or NC with the Inputs normally open closed programming code 41 ...

Page 7: ...n after pressing the emergency button to indicate the beginning of the alarm procedure The RECEIVED ALARM INDICATOR LIGHT green switches on when the alarm call is answered It is also possible to connect external indicator lights Connect following one of the diagrams shown below the external indicator lights to the Helpy Compact Q Output 12 Vdc factory setting Output 0 Vdc ...

Page 8: ...ion Connect the telephone line to LTI terminals CONNECTING THE LOCAL TELEPHONE Connect the local telephone for programming and managing the device to TEL and terminals irrespective of the polarity CONNECTING THE RESET CONTACT It is possible to use a voltage free contact NO or NC Connect the reset contact to AL2 and terminals CONNECTING THE RELAY Connect the external contact to RL1 NO or RL1 NC and...

Page 9: ...WIRING DIAGRAMS Page 9 WIRING DIAGRAMS ...

Page 10: ...URNING ON Connect the external 12 Vdc 30 Vdc power supply to and terminals Helpy Compact Q lights up and the device status LED starts flashing TURNING OFF Disconnect the external 12 Vdc 30 Vdc power supply from and terminals The device status LED turns off ...

Page 11: ...To listen again to the previous message lift the handset and dial Make an external call to check the PSTN line or the universal gateway is properly working dial and digit the telephone number to make a test call 2 TESTING THE ALARM PROCEDURE Press the emergency call button for more than 3 seconds factory value The alarm starts 3 ANSWERING THE ALARM Note the activation mode of the communication wit...

Page 12: ...ry default Press to end the alarm 2nd mode automatic reset Hang up or press to end the alarm 3nd mode automatic reset with local acknowledgement Hang up to end the call Press the reset pushbutton or close the reset input to end the alarm An end of alarm call will be generated Answer by the called party Press Without local acknowledgement the alarm is automatically ended after 6 hours Note the rese...

Page 13: ...at page 2 Pressing shortly Allows to interrupt an alarm call By pressing shortly you get the same result as lifting the handset of the local telephone and entering Password Pressing longer 10 seconds Allows to reset the device By pressing longer the Helpy Compact Q will be re started with no need to disconnect the power supply Note it is also possible to reset the device through the code 995 0 ...

Page 14: ...CESS TO PROGRAMMING INSTALLER or OPERATOR PASSWORD factory default EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD factory default TELEPHONE NUMBERS INST the programming of the telephone number automatically activates the alarm call position from 01 to 24 SOURCE RECEIVER X X telephone number max 20 digits 2 sec pause emergency call button battery alarms USER periodic automatic test call ESS...

Page 15: ... TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY TIME INST hhmm from 0000 to 2359 RECORD MESSAGES INST identification message max 25s record hang up courtesy message max 25 s LISTEN TO MESSAGES INST OPER identification message listen courtesy message LOW BATTERY ALARM INST disabled alarm enabled alarm BATTERY VOLTAGE THRESHOLD INST mV from 1 to 5 digits factory default 11500 ...

Page 16: ... EN 81 28 2004 Make a test call manually PROTOCOLS IDENTIFICATION CODE INST Esse ti identification code P100 SPEAKER UNITS VOLUME INST OPER loudspeaker from 1 to 9 factory default 3 microphone from 1 to 9 factory default 5 MESSAGES VOLUME INST OPER from 1 to 4 factory default 3 4 loudspeaker volume 3 of loudspeaker volume 2 of loudspeaker volume 1 of loudspeaker volume LISTEN TO THE PROGRAMMING AG...

Page 17: ... INST for the complete configuration of the inputs please refer to the Expert Programming Guide AL2 alarm input IN1 filter input AL2 auxiliary input IN1 filter input AL2 alarm input IN1 gong input AL2 auxiliary input IN1 gong input AL2 reset input IN1 filter input AL2 reset input IN1 gong input AL2 reset input IN1 alarm input AL2 reset input IN1 auxiliary input AL2 alarm input IN1 alarm input in l...

Page 18: ...cation 201 16 18 X telephone number where X receiver notification mode 2 user 3 Esse ti 4 CLI 6 P100 if receiver 3 set the Esse ti protocol ID 222 YYYYYYYYYY if receiver 6 set the P100 protocol ID 223 ZZZZZZZZZZ if receiver 6 customize the P100 protocol codes using the e stant software programming code 203 Note AL2 and IN1 are automatically configured as normally closed if the connected contacts a...

Page 19: ...02 to 59 00 no courtesy message 01 one courtesy message for each call CALL DELAY AFTER COURTESY MESSAGE INST seconds of waiting after the courtesy message before sending the call from 0 to 9 factory default 3 PLAYBACK OF COMMUNICA TION ACTIVA TED MESSAGE WHEN THE SPEAKER UNIT IS ACTIVATED INST never only in case of remote connection always TWO WAY COMMUNICATIO N MODE DURING AN ALARM INST two way c...

Page 20: ...uese 06 Russian 07 Spanish 09 Czech MULTI LANGUAGE COURTESY MESSAGE INST second language third language TONE DECODER INST country 00 IT SM AL BA GM MK MT NO 01 GB AE 02 DE LB LU 03 FR GP GF 04 PL 05 PT 06 RU BY 07 ES AD CY 08 BG BR KY DK ID IR IS KW MO MW MX PY UY VE YE ZM FO LR 10 HR 11 GR EE FI 12 NL AW VU 13 SI 14 HU 15 IL 16 AT 17 AU IE 18 CH 19 CN 20 US CA JM AI AG BB BM VG DM MS KN TT TC 21 ...

Page 21: ...TEST CALLS TO THE SAME NUMBER INST minutes from 01 to 99 00 30 seconds factory default 02 DURATION OF CALL TO EACH NUMBER INST seconds from 15 to 60 CLI CALL DURATION INST seconds from 00 to 99 factory default 10 AUTOMATIC ANSWER INST ring number from 1 to 9 0 disabled factory default 2 OPERATION MODE AFTER AUTOMATIC ANSWER INST programming mode direct connection with the car CONNECTION DURATION A...

Page 22: ...ses active as long as the buttons are pressed active for telephone line absence active for low battery RELAY INTERMITTENCE INST steady state intermittent 500 ms ON 500 ms OFF LISTEN TO THE BATTERY LEVEL INST expressed in mV TEST OF ALARMS INST emergency call button battery alarm periodic automatic test call built in speaker unit diagnostic alarm auxiliary alarm end of alarm ...

Page 23: ... customizing the messages and updating the firmware of the Helpy Compact Q e stant can be downloaded at the following link https www esse ti it en download software request Local programming via micro SD card The micro SD card properly set allows to program the Helpy Compact Q update the firmware of the Helpy Compact Q customize the messages of Helpy Compact Q To use of the micro SD card see the r...

Page 24: ...S TELEPHONE NUMBER DOOR OPENER RELAY Use remotely with Helpy Compact Q at rest Call Helpy Compact Q and wait for a response Listen to the elevator identification message if present Dial to speak with all speaker units or Dial password factory default to access programming All of the programming and functions below can now be performed USE REMOTELY WITH HELPY COMPACT Q AT REST PROGRAMMING CONVERSAT...

Page 25: ...SIGNALS Page 25 SIGNALS Device status LED Normal operation no alarm Alarm Voice connection Low battery max 1 hour operation in idle state Absence of telephone line Button failure ...

Page 26: ... test call notification EN 81 28 2018 The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call The flashing sequence ends after the next successful test call or emergency call Given alarm indicator light Received alarm indicator light ...

Page 27: ...ti S r l declares that the equipment type Helpy Compact Q is in compliance with Directives 2014 33 EU 2014 53 EU The full text of the EU declaration of conformity is available from the following Internet address https www esse ti it en dichiarazioni di conformita ...

Page 28: ...Esse ti S r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it support esse ti it ...