USE 

Page 29  

USE 

Local use 

 : lift the local telephone handset 

 

: lift the local telephone handset and dial 

  to access programming. 

 

LOCAL USE

CONVERSATION 
WITH THE 
SPEAKER UNITS 

 CONVERSATION 

 

 CABIN SPEAKER UNIT (ID 01) 

 

 SPEAKER UNIT ID 02 

 

 SPEAKER UNIT ID 03 

 

 SPEAKER UNIT ID XX (04~16) 

PROGRAMMING 

 

 

CONVERSATION 
WITH THE 
SPEAKER UNITS 

 

 CABIN SPEAKER UNIT (ID 01) 

 

 SPEAKER UNIT ID 02 

 

 SPEAKER UNIT ID 03 

 

 SPEAKER UNIT ID XX (04~16) 

 

 

 DEACTIVATE ALL 

EXTERNAL CALLS 

  

 <TELEPHONE NUMBER> 

DOOR OPENER 
RELAYS 

  

 

 

 
 

Summary of Contents for HELPY 2W-LCP

Page 1: ...17 01 2019 Alarm system for elevators compliant with the European Standard EN 81 28 2018 HELPY 2W LCP QUICK GUIDE...

Page 2: ...plug for connection to elevator CPU D RJ45 connector for GSM200 C module E RJ11 connector for local telephone F Connectors for optional PSTN line board G Serial port for PC connection H Reset pushbut...

Page 3: ...ary input 4 BUS Bus for connecting 2W speaker units BUS Bus for connecting 2W speaker units TEL Local telephone Negative Optional PSTN line board LTI PSTN line or universal GSM gateway input Ground te...

Page 4: ...C module Please see also the GSM200 C User Manual Connect the RJ45 connector D in the picture at page 2 to the GSM200 C module by means of the supplied cable PSTN line or universal GSM gateway Insert...

Page 5: ...ton and indicator lights Note a passive speaker unit must be connected to a 2W speaker unit and allows to double it The passive speaker unit can be installed at max 6 m distance from the 2W speaker un...

Page 6: ...r supply input 12 Vdc Negative AR Received alarm indicator light light positive pole AI Given alarm indicator light light positive pole AR Received alarm indicator light light negative pole AI Given a...

Page 7: ...ing microphone of passive speaker unit or single microphone Negative H Microphone DIP switch The DIP switch allows to assign an ID 01 16 to each 2W speaker unit connected to the bus Note it is possibl...

Page 8: ...to each 2W speaker unit or directly to the Helpy 2W LCP 2W speaker unit Some 2W speaker units come with a built in pushbutton It is also possible to connect external pushbuttons voltage free contact p...

Page 9: ...CONNECTING THE EMERGENCY CALL BUTTONS Page 9 Helpy 2W LCP It is possible to connect voltage free contact pushbuttons Connect the pushbuttons following one of the diagrams shown below...

Page 10: ...ER INPUT CONNECTING THE FILTER INPUT Connect following one of the diagrams shown below the filter contact Note it is also possible to connect the filter contact to the filter input of the 2W speaker u...

Page 11: ...EIVED ALARM INDICATOR LIGHT green switches on when the alarm call is answered It is possible to connect the indicator lights to each 2W speaker unit or directly to the Helpy 2W LCP 2W speaker unit Som...

Page 12: ...Page 12 CONNECTING THE INDICATOR LIGHTS Helpy 2W LCP Connect following the diagram shown below the external indicator lights to the Helpy 2W LCP...

Page 13: ...ice CONNECTING THE AUXILIARY INPUTS Helpy 2W LCP It is possible to configure the IN2 input of Helpy 2W LCP as auxiliary input Connect the external contact as per one of the modes shown in the table C...

Page 14: ...Page 14 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAM WITH 2W SPEAKER UNITS IN THE CAR AND IN THE PIT AND PASSIVE SPEAKER UNIT ON CAR TOP...

Page 15: ...WIRING DIAGRAMS Page 15 WIRING DIAGRAM WITH LANDING FLOORS...

Page 16: ...hang up To listen again to the previous message lift the handset and dial Make an external call to check the GSM200 C module is properly working dial and after the Correct message digit the telephone...

Page 17: ...he trapped person 4 RESETTING THE ALARM Note the alarm reset mode can be configured with the Alarm reset mode programming code 77 1st mode reset by End code factory default Press to end the alarm 2nd...

Page 18: ...TON Note the reset operation does not alter the previously set parameters Use of the reset pushbutton H in the picture at page 2 Pressing shortly Allows to interrupt an alarm call By pressing shortly...

Page 19: ...PERATOR PASSWORD factory default EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD factory default TELEPHONE NUMBERS INST the programming of the telephone number automatically activates the alarm...

Page 20: ...GSM200 C module DATE INST WEEKDAY dd mm yy SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY TIME INST hhmm from 0000 to 2359 RECORD MESSAGES INST identification message max 25s record hang up...

Page 21: ...18 automatic test enabled EN 81 28 2004 Make a test call manually PROTOCOLS IDENTIFICATION CODE INST Esse ti identification code P100 SPEAKER UNITS VOLUME INST OPER speaker unit terminal ID from 01 to...

Page 22: ...Y 2W LCP INPUTS SETTING INST AL2 alarm IN1 filter IN2 gong AL2 auxiliary IN1 filter IN2 gong AL2 alarm IN1 filter IN2 auxiliary AL2 auxiliary IN1 filter IN2 auxiliary AL2 reset IN1 filter IN2 gong AL2...

Page 23: ...ILTER INPUT NORMALLY CLOSED OPEN INST OPER normally closed normally open FILTER BYPASS INST seconds from 15 to 30 ALARM OPERATION WITHOUT TELEPHONE LINE INST AI indicator light lit and courtesy messag...

Page 24: ...Polish 05 Portuguese 06 Russian 07 Spanish MULTI LANGUAGE COURTESY MESSAGE INST second language third language TONE DECODER INST country 00 IT SM AL BA GM MK MT NO 01 GB AE 02 DE LB LU 03 FR GP GF 04...

Page 25: ...ion with the car CONNECTION DURATION AFTER AUTOMATIC RESPONSE INST minutes from 1 to 9 CLI CALL DURATION CLI seconds from 00 to 99 factory default 10 MULTI LINK FUNCTION INST from 0 to 9 1 master 0 fu...

Page 26: ...nnection not guaranteed 13 18 low signal 19 24 medium signal 24 high signal ENTER PIN CODE WHEN PIN ACTIVE INST PIN PIN DISABLE PIN REQUEST INST LISTEN TO THE BATTERY LEVEL INST expressed in mV LISTEN...

Page 27: ...essages of the Helpy 2W LCP set a micro SD card to use for programming customizing the messages and updating the firmware of the Helpy LCP e stant can be downloaded at the following link https www ess...

Page 28: ...assword which allows access to programming and the programming codes to be performed The message format must be as follows Et he xxx c c c c Where Et he is the start of the programming string xxx is t...

Page 29: ...VERSATION WITH THE SPEAKER UNITS CONVERSATION CABIN SPEAKER UNIT ID 01 SPEAKER UNIT ID 02 SPEAKER UNIT ID 03 SPEAKER UNIT ID XX 04 16 PROGRAMMING CONVERSATION WITH THE SPEAKER UNITS CABIN SPEAKER UNIT...

Page 30: ...unit ID 02 to speak with the speaker unit ID 03 to speak with the cabin speaker unit ID XX 04 16 or Dial password factory default to access programming All of the programming and functions below can n...

Page 31: ...lling device status red Normal operation no alarm Alarm Voice connection Battery disconnected or low battery max 1 hour operation in idle state 2W speaker unit connection error or bus problem Absence...

Page 32: ...Page 32 SIGNALS LED signalling GSM200 C signal strength green No signal Low signal level Medium signal level Good signal level High signal level...

Page 33: ...Missed test call notification The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call The flashing sequence ends a...

Page 34: ...se ti S r l declares that the equipment type Helpy 2W LCP is in compliance with Directives 2014 30 EU 2014 33 EU 2014 35 EU The full text of the EU declaration of conformity is available from the foll...

Page 35: ...NOTE Page 35 NOTE...

Page 36: ...Esse ti S r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it support esse ti it...