background image

 

Page 36 

Sending SMS  

Text  messages  transmitted  from  an  external  device  to  the  4G.VoLTE 
CAN, through the DB-9 connector, are sent via SMS when they comply 
with the following format: 

ES^SMSX…X:Y…Y<CTRL+Z>

 

where: 
ES^SMS    

string start   

X...X 

 

telephone number on which the SMS must be sent 

Y...Y  

 

message text to be sent (max. 160 characters) 

<CTRL+Z>   

non-editable character defining end of text  

The SMS can be sent to the number programmed for notifications (code 
40). In this case, the text format is required to be as follow: 

 

ES^SMS:Y…Y<CTRL+Z>

 

Note: to send SMS, the 4G.VoLTE must be correctly 

registered to the mobile network and the SIM card 
must be topped up. 

Note: for CAN-bus communication please refer to 

corresponding  documentation. 

Notifications sent from 4G.VoLTE CAN to the external device: 

String

 

Meaning

^SMSREC<CTRL+Z>

SMS t

aken in charge

 

^SMSOK<CTRL+Z>

SMS sent correctly 

^SMSERROR<CTRL+Z> 

error in sending the SMS 

^SMSBUSY<CTRL+Z> 

4G.VoLTE CAN being registered to the network or not 

registered 

 

 

Summary of Contents for 4G.next Voice

Page 1: ...27 04 2021 7IS 80490 User s manual...

Page 2: ...recommendations 14 Absorption chart 14 PROGRAMMING 15 Programming by telephone 15 1 SIM card expiration check 22 2 Battery check 22 3 External power failure control 23 4 Relay based notification of ex...

Page 3: ...MS 37 Sending e mails 37 DATA TRANSMISSION 39 FEMALE DB 9 CONNECTOR 42 SIGNALS 43 Tones 43 Call signals 44 LED 44 4G LTE UMTS GSM signal indicator LED GREEN 44 Status indicator LED RED 45 Line status...

Page 4: ...repair The device must be installed in a ventilated place making sure that the ventilation slots are never obstructed Do not install the product in environments with risk of explosion Make sure that...

Page 5: ...relay output which can be activated either locally or remotely via SMS 4G VoLTE CAN 4G VoLTE CAN gateway also comes with a female DB 9 connector for data transmission and SMS and e mails forwarding F...

Page 6: ...al power failure restore 4G LTE UMTS GSM network restore Measurement of 4G LTE UMTS GSM signal level Periodic test Automatic converter of selected telephone number Receiver and transmitter gain adjust...

Page 7: ...t NiMH 800 mAh 7 2 V back up battery Female DB 9 connector 4G VoLTE CAN only Relay output External antenna cable length 2 m External adapter 230 Vac 50 Hz input 12 Vdc 500 mA output CE mark LED The ga...

Page 8: ...ply status blue D Female DB 9 connector 4G VoLTE CAN only E RS 485 termination jumper 4G VoLTE CAN only F CAN bus termination jumper 4G VoLTE CAN only G Telephone line output RJ11 connector for teleph...

Page 9: ...ard into its housing cover Lower the SIM card housing cover and shift it upward until it blocks WARNING The SIM card PIN must be DISABLED If the PIN is enabled it must be disabled through a mobile pho...

Page 10: ...telephone line Connect the gateway to a standard telephone or to the PSTN input terminals of a PABX or autodialer via the RJ 11 connector G in the picture at page 8 or Connect the gateway to a standar...

Page 11: ...in the picture at page 8 taking care to respect the polarity Connect the backup batteries to the dedicated input N in the picture at page 8 Close the gateway cover paying attention to the power supply...

Page 12: ...network Make sure the red LED device status flashes as shown in chapter Signals see page 45 If the red LED stays lit permanently the gateway has not properly registered with the 4G LTE UMTS GSM provi...

Page 13: ...tify an area where the signal is strong enough Note the signal strength may vary according to the telephone provider Drill two holes with 5 mm diameter on the wall at a distance of 50 mm Insert the 2...

Page 14: ...Personal Computers wired radio systems etc or magnetic devices that could be subjected to RF interference from the module recommended distance from the antenna is min 2 5 m Do not install the gateway...

Page 15: ...ne will be heard in case of error In any case the dialling tone will follow after which you can proceed with the programming or make a call Note during programming the inter digit dialling time must n...

Page 16: ...devices effecting tone detection over the line INTER DIGIT DIALLING TIME 8 X X seconds from 1 to 9 0 10 seconds 5 factory default CLIP SETTING 7 1 DDMMYY HH MM Enabling DD day MM month YY year HH hou...

Page 17: ...umber appointed for SMS notifications of SIM card expiration battery external power failure restore mobile network restore and for SMS reading SIM expiration 40 Deleting ADMINISTRATOR TELEPHONE NUMBER...

Page 18: ...5 h e 30 4 4 h 5 2 h e 30 6 1 h e 30 7 1 h minimum number of operating hours in idle mode guaranteed by the battery charge below this threshold a notification SMS is sent out EXTERNAL POWER FAILURE CO...

Page 19: ...e relay is activated in case of mobile network loss 6 the relay is activated in case of external power failure or in case of mobile network loss PERIODIC TEST 5 72 X X X X X X telephone number appoint...

Page 20: ...ALED NUMBER X X programming password Y table position from 1 to 6 25 X X DELETING ALL DIALED NUMBERS X X programming password TRANSMITTER GAIN ADJUSTMENT 10 X X value from 1 min to 7 max 4 factory def...

Page 21: ...a bitmask 0x1 Mode 0 6 60 kbps 0x2 Mode 1 8 85 kbps 0x4 Mode 2 12 65 kbps 0x8 Mode 3 14 25 kbps 0x10 Mode 4 15 85 kbps 0x20 Mode 5 18 25 kbps 0x40 Mode 6 19 85 kbps 0x80 Mode 7 23 05 kbps 0x100 Mode 8...

Page 22: ...s sent with the following text message SIM expiring Note the days internal counter stops when the gateway is powered off and restarts at the next power on 2 Battery check If the battery check is enabl...

Page 23: ...a time interval equal to the preset threshold a new SMS will be sent with the following text message External power restored 4 Relay based notification of external power failure and or mobile network...

Page 24: ...ber the call will be automatically forwarded to the first preset telephone number Note to enable the Automatic converter service you simply need to preset one telephone number to disable this service...

Page 25: ...ne autodialer or other telephone device with the gateway The gateway will check if the number is already matched with a preset telephone number If so it will send a call to the preset number If not it...

Page 26: ...ramming outgoing SMS from the Internet may not be successful if the requested format is not respected Message format The message format is required to be as follows ET IL2 xxx c c where ET IL2 program...

Page 27: ...sword 19 X X Y Y Y Y Enabling SIM card expiration check 53 X X Disabling SIM card expiration check 53 0 Reading SIM card expiration check status 53R Battery check enabling 50 Battery check disabling 5...

Page 28: ...Transmitter gain setting 10 X Reading transmitter gain 10R Receiver gain setting 11 X Reading receiver gain 11R Duration of VoLTE DTMF tones 06 X X Reading duration of VoLTE DTMF tones 06R Volume of...

Page 29: ...ator who previously sent out a programming SMS is the same as the programming message format SMS notifying an accepted command ET IL2 xxx c c SMS notifying a rejected command ET IL2 xxx c cERR Example...

Page 30: ...E UMTS GSM network If the gateway is connected to a PABX please refer to the switchboard s manual If the gateway is connected to a telephone Pick up the handset The LED indicating the line status whit...

Page 31: ...m 3 Tones Good 4 Tones High Since the signal can be subject to variations we recommend repeating the code 30 2 or 3 times a few seconds apart in order to have a reliable measurement Note in case of lo...

Page 32: ...tone will be received if the SIM card expiration control is disabled if the notification number to be alerted has not been previously entered or if the gateway is not correctly registered to the 4G L...

Page 33: ...s you to activate or deactivate the relay Lift the handset and dial 92 Enter 0 to deactivate the relay 1 to activate the relay Dial to confirm After the confirmation tone hang up Pulse Allows you to a...

Page 34: ...illustrative purposes Meaning ET IL2 XXX 904G NET String start 210010001 Feb 4 2020 12 07 15 4G VoLTE software version 25 20 228 T206 POF 229401MOF 220008 T2060A Radio module data 354033074014898 IME...

Page 35: ...only after the communication standard programming 57 XYWZ X bits per second parameter from 1 to 9 1 RS 232 485 115200 CAN bus 1M 2 RS 232 485 57600 CAN bus 500k 3 RS 232 485 38400 CAN bus 250k 4 RS 23...

Page 36: ...be sent to the number programmed for notifications code 40 In this case the text format is required to be as follow ES SMS Y Y CTRL Z Note to send SMS the 4G VoLTE must be correctly registered to the...

Page 37: ...e mail when it complies with the following format ES MAILX X CTRL Z Y Y CTRL Z Z Z CTRL Z where ES MAIL string start X X e mail address of recipient max 50 characters Y Y subject of the e mail to be s...

Page 38: ...ered 4G VoLTE CAN configuration for connection to COMNet Server Send the following configuration SMS to 4G VoLTE CAN ET IL2 xxx 62 n n n n Cy y Fw w Gz z 13 u where ET IL2 programming string start xxx...

Page 39: ...ional serial communication which is commonly performed locally i e between peripherals and custom boards Fig A or between a PC based proprietary application and a lift controller board Fig B Figure A...

Page 40: ...or use similar proprietary application PC application mobile app web server or other solution respecting the COMNet protocol Figure D example of COMNet system Figure E example of COMNet system The COM...

Page 41: ...r voice transmission by means of the dedicated plug or connector i e it can be connected with the elevator emergency phone dialer and the same SIM card needed for remote monitoring 4G VoLTE CAN can ma...

Page 42: ...Page 42 FEMALE DB 9 CONNECTOR RS 232 TX PIN2 RX PIN3 GND PIN5 RS 485 TXD PIN6 TXD PIN7 GND PIN5 CAN bus CANH PIN8 CANL PIN9 GND PIN5...

Page 43: ...der or a delay in dialling or the end of conversation or an access to services not permitted Busy It indicates that the called party is busy Confirmation It indicates that the requested service or pro...

Page 44: ...evel It indicates no signal CALL SIGNALS It indicates an incoming call LED 4G LTE UMTS GSM signal indicator LED GREEN It indicates no signal It indicates low signal level It indicates medium signal le...

Page 45: ...indicator LED Data transmission indicator LED WHITE It indicates that the line is in use or that a data connection is in progress It indicates that the line is not in use and the gateway is registere...

Page 46: ...Page 46 It indicates that the line is not in use and the gateway is registered to a 4G network with high signal level It indicates an incoming call...

Page 47: ...connected and the battery guarantees 1 hour operation in idle state It indicates that the external power supply is connected and the battery is absent or damaged It indicates that the external power...

Page 48: ...e Check the signal strength by your mobile phone Insufficient power supply Check the power supply Generic SW problem Switch off and back on the gateway The red LED blinks but the green LED is unlit Si...

Page 49: ...e ti S r l declares that the equipment type 4G VoLTE is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available from the following Internet address https...

Page 50: ...Page 50...

Page 51: ...Page 51...

Page 52: ...Esse ti s r l via G Capodaglio 9 62019 Recanati MC ITALY tel 39 071 7506066 fax 39 071 7506057 support esse ti it www esse ti it...

Reviews: