3.5) Signals wires connection.

3.5) Signals wires connection.

3.5) Signals wires connection.

3.5) Signals wires connection.    

Single

Single

Single

Single----phase version

phase version

phase version

phase version    

    

Three

Three

Three

Three----Phase Version

Phase Version

Phase Version

Phase Version    

    

 

Figure 6

Figure 6

Figure 6

Figure 6    

 

Figure 7

Figure 7

Figure 7

Figure 7    

 

1.-  RS 485 communications output to connect various inverters. Up to 4 units. 

2.-  Auxiliary input for an external level switch or a potential-free contact to activate or stop the circuit. 

Note: This input is supplied from the factory with an electric cable bridge. 

3.-  Input of the 4-20mA pressure transducer. 

4.-  Potential-free auxiliary input. Not used. 

5.-  Auxiliary transducer input. Not used. 

6.-  Only  in  single-phase  versions.  230  V  potential  output,  2A  maximum,  external  display  or  acoustic 

operation for alarm signals. 

7.-  Micro-switches used to configure the inverter's operation. 

 

  

WARNING: All external cabling connections must use terminal tips on the ends of each cable. External 
cables  must  comply  with  the corresponding electrical safety and insulation regulations. Installation 
should be made by qualified service personnel. 

 

Avoid any cable pieces from falling inside the circuit, which could lead to its destruction. 

 

DANGER. Risk of electrocution. 
If the unit has to be uncovered due to any circumstance, first disconnect the power supply and wait 5 
minutes  before  starting  work  with  the  circuit.  The  circuit's  capacitors store energy. There is enough 
energy inside the circuit to cause a strong electric discharge, even when the unit is not powered.  

 

Summary of Contents for SPEEDRIVE

Page 1: ...SPEEDRIVE INSTRUCTIONS MANUAL INSTRUCTIONS MANUAL INSTRUCTIONS MANUAL INSTRUCTIONS MANUAL EN EN EN EN...

Page 2: ...he pump or the installation TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS 1 GENERAL INFORMATION 3 2 TECHNICAL SPECIFICATIONS 3 2 1 Models 3 2 2 Dimensions 3 2 3 Features 3 3...

Page 3: ...his Manual can lead to motor overloads diminishment in technical characteristics reduction of the unit s working life and all types of subsequent results for which we decline any responsibility 2 TECH...

Page 4: ...es are primed completely 3 2 Elect 3 2 Elect 3 2 Elect 3 2 Electrical connection to the motor rical connection to the motor rical connection to the motor rical connection to the motor 3 2 1 Speedrive...

Page 5: ...inverter set DANGER Risk of electrocution Never open the Speedrive cover before disconnecting the power supply during at least 5 minutes least 5 minutes least 5 minutes least 5 minutes Figure 2 Figure...

Page 6: ...e Three Three Three Phase Version Phase Version Phase Version Phase Version Prepare the motor wires with ferrites connect the grounding wire 2 Connect the motor wires to the provided socket 3 Single S...

Page 7: ...size Motor size Motor size Motor size Leakage current Leakage current Leakage current Leakage current 0 75 to 3 kW 3 5 mA 4 to 5 5 kW 5 mA The electrical installation should have a multiple separatio...

Page 8: ...used 5 Auxiliary transducer input Not used 6 Only in single phase versions 230 V potential output 2A maximum external display or acoustic operation for alarm signals 7 Micro switches used to configur...

Page 9: ...equipped pumps point for equipped pumps Do not need any further adjustment Do not need any further adjustment Do not need any further adjustment Do not need any further adjustment Speedrive module pur...

Page 10: ...ressure The pump will run automatically as needed To display parameters press View To return to the start screen press Menu MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION It shows...

Page 11: ...by experts ADDITIONAL PARAMETERS SETTING ADDITIONAL PARAMETERS SETTING ADDITIONAL PARAMETERS SETTING ADDITIONAL PARAMETERS SETTING FINE ADJUSTMENTS FINE ADJUSTMENTS FINE ADJUSTMENTS FINE ADJUSTMENTS T...

Page 12: ...does not have to be determined since the circuit communications system detects its number DELAY ON DELAY ON DELAY ON DELAY ON Delay time between the activation of auxiliary pumps Avoid continuous star...

Page 13: ...T PROPORTIONAL CONSTANT START PROPORTIONAL CONSTANT START PROPORTIONAL CONSTANT START PROPORTIONAL CONSTANT Allows the variation of the unit s proportional constant upon start up STAR INTEGRAL CONSTAN...

Page 14: ...o the main screen 2 1 From any screen tap OK to return to the main screen 2 1 From any screen tap OK to return to the main screen 2 1 From any screen tap OK to return to the main screen 2 1 OVERCURREN...

Page 15: ...m will stop when a short circuit is detected in the motor The reset is automatic If the error is not solved 4 new attempts are performed If the error is still present after the fourth attempt the syst...

Page 16: ...rious Espa solutions for a multiple pump booster set control a Booster set with On Off auxiliary pumps equipped with ELV box b Booster set with inverter regulated auxiliary pumps equipped with Speedri...

Page 17: ...rrent of the auxiliary pumps according to his motor s data plate plus 10 plus 10 plus 10 plus 10 All auxiliary pump motors should be of the same power CHANGE FREQUENCY CHANGE FREQUENCY CHANGE FREQUENC...

Page 18: ...is done as described in this manual The connection of the pressure transducer must be made solely on the Master Speedrive A 2 wire twisted and shielded cable 0 5mm2 section must make the communication...

Page 19: ...menu as follows MOTOR FREQUENCY MOTOR FREQUENCY MOTOR FREQUENCY MOTOR FREQUENCY Configuration of the nominal frequency of the motor 50Hz or 60Hz Check the motor s nameplate Note This screen only appea...

Page 20: ...ELECTROMAGNETIC COMPATIBILITY Speedrive M1 and M2 are in compliance with directive 2004 108 CE electromagnetic compatibility for industrial environment For residential environment it will require the...

Page 21: ...21 10 MENU DIAGRAM 10 MENU DIAGRAM 10 MENU DIAGRAM 10 MENU DIAGRAM...

Page 22: ...22...

Page 23: ...23...

Page 24: ...Cod 155854 Cod 155854 Cod 155854 Cod 155854 11 11 11 11 2010 05 2010 05 2010 05 2010 05 ESPA 2025 S L C Mieres s n 17820 BANYOLES GIRONA SPAIN www espa com...

Reviews: