Memo
Technical Helpline - 0121 786 1881
Page 1: ...For your protection please read these instructions completely and keep it for future reference 6320000028H Enterview Multi ...
Page 2: ...installed and used in accordance with the instructions may cause harmful interference to radio communication However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning equipment on and off the user is encouraged to try to correct the interference by...
Page 3: ...by battery or other power source consult the operating instructions 10 Grounding and Polarization This unit may be equipped with either a polarized 2 wire AC line plug a plug having one blade wider than the other or a 3 wire grounding type plug a plug having a third grounding pin The 2 wire polarized plug will fit into the power outlet only one way This is a safety feature If you are unable to ins...
Page 4: ...terview Multi System is the ideal communication solution for apartment and condominium Front panel Side Bottom panel or Position the camera adjustment to get better view and tighten the screws on it with a philip screwdriver before installation 1 Press in the direction of arrow to remove the transparent plate 2 Fill in name or room number with an oil soluble pen etc 3 Attach the plate to the front...
Page 5: ...the front panel with provided hexagonal screws 4 Leave the front panel unattached on the wall before you make sure all the stations have been installed and wired properly Wiring Plug wires from tenant monitor into connectors on the camera respectively according to illustrated diagrams as below Note 1 The connection between wires and connectors should be completed in the reverse side of your desire...
Page 6: ...stalled it functions in the following way To unlock the door during conversation Press door open button The image on the screen disappears when door open button is pressed Specifications Enterview Multi Remark Specification Power Source Regulated DC 12V Power Consumption DC 12V 230mA 330mA Display output 1Vp p 75 Composite CCIR EIA PAL NTSC Maximum Wiring Distance 0 65 AWG22 0 8 AWG20 mm 50m 165 f...
Page 7: ...llation Wiring Installation Extension Panel With Jointers Wiring 1 Put the wires into connectors between the modules 2 Remove the stopper of each flush box 3 Pass the wire A through the jointers and plug to connector B Enterview Multi 10 11 ...