26
ALL ABOUT IMAGE RECOGNITION & PROCESSING
9. FACTORY DEFAULT
Press [ENTER] button when half-tone green bar is in on
FACTORY DEFAULT.
FACTORY DEFAULT
ALL SETUP
CAMERA COLOR
CAMERA TITLE
MOTION MASK
PAN/TILE COMMAND
SYSTEM STATUS
RUN
HDD MANAGEMENT
1) CAMERA COLOR
SELECT
, EDIT ENTER /
FACTORY DEFAULT is parameters setting done just
before delivery by manufacturer, and manufacturer
recommend our users to use DVMR unit with settings
done by manufacturer until our users become to have full
understanding about DVMR system.
FACTORY DEFAULT can be set group by group or as a
whole at once.
Parameter settings about color of camera like brightness,
contrast and others of camera. If we set CAMERA COLOR
at YES, all changes you made in ADJUST COLOR/
CAMERA SETUP shall be deleted and return to settings
done by manufacturer before delivery.
2) CAMERA TITLE
Default camera title is CH-01, CH-02, and so on.
3) MOTION MASK
Motion mask is for motion detection area, motion window, and sensitivity.
If we set MOTION MASK at YES, all changes you made in MOTION SETUP/CAMERA SETUP shall
be deleted and return to settings originally done by manufacturer.
4) PAN/TILT COMMAND
As explained in PAN/TILT COM SETUP/MISCELLANUOUS SETUP, this DVMR system includes
built-in protocol models like PELCO D type and we can select model of PTZ camera connected to
DVMR unit.
In case PTZ camera you are going to connect to DVMR unit is not one of models whose protocol is
already incorporated into DVMR system, you can input protocol of PTZ camera in USER DEFINE
mode/PAN TILT SMD SETUP menu.
Even though you set PAN/TILT COMMAND at YES, built-in protocol remain unchaged
However, protocol you input in USER DEFINE model is deleted if you set PAN/TILT COMMAND at
YES and set at FACTORY DEFAULT. Be careful not to set at YES to keep protocol you input as a
USER DEFINE model.
5) SYSTEM STATUS
It is setting related recording parameters like recording speed, IP address, and others related to
system. If you set SYSTEM STATUS at YES and set at FACTORY DEFAULT, you have to set
recording speed, and input IP address and others again.
6) ALL SETUP
If you set ALL SETUP at YES and set at FACTORY DEFAULT, all groups of FACTORY DEFAULT are
initialized. That is, all parameter settings is done again just as done by manufacturer before deliverly.
---
NO
NO
NO
NO
NO
8 channel stand-alone DVMR