17

Technical Data

Wireless Programmable Room Thermostat

 

Programming

Power Supply

Temperature 

Sensor Type

Switching Sensitivity

Temperature 

Adjustment Range

Plastic

Protection Rating

Dimensions

Number of Events

per Day

BST/GMT Time Change

Factory Pre-Set

Programme

Complies with:

7 Day, 5/2 Day & 24Hr

2 x 1.5V Alkaline Batteries 

(type: AA size)

NTC 10k ῼ+/- 1% at 25oC

+/-0.2oC or 0oC/-0.2oC

7oC to 34oC

Thermoplastic, flame retardant

IP30

130mm(L) x 80mm(W) 

x 35mm(D)

Up to 6
Automatic

Yes

EN60730-1 EN 60730-2.7, EMC 

Directive 2004/108/EC, LVD 

Directive 2006/95/EC

Transmission Distance Approx. 30m in open terrain

Summary of Contents for ESRTPRF

Page 1: ...User and Installation Instructions ESRTPRF Wireless Programmable Room Thermostat with Delayed Optimum Start M A MANUAL...

Page 2: ...s...

Page 3: ...rogramme 6 Choosing Between 7 Day 5 2 Day 24hr Operation 7 Permanent Manual Overrides 7 Temporary Manual Overrides 8 Holiday Mode 9 Party Mode 10 Frost Protection 10 Setting the Time and Date 11 Chang...

Page 4: ...17 Installation Safety Instructions 19 General Safety Instructions 19 Maintenance 20 Safety Notice 20 Fitting the Programmable Room Thermostat 21 Fitting the Receiver 24 Wiring Diagram 26 Receiver Man...

Page 5: ...User Instructions...

Page 6: ...use temperature and ON house temperature usually 20 c less energy will be required to bring the house temper ature back up to 20 c when the heating is turned back ON The recommended set back OFF tempe...

Page 7: ...sures simpli ed program ming and operation for all users What is Delayed Start Thermostats with the Delayed Start function have been shown to reduce heating costs by as much as 10 This feature delays...

Page 8: ...the Optimum Start function you don t need to do this The actual start time is automatically delayed or advanced to ensure your home reaches the set temperature by the programmed time The Optimum Start...

Page 9: ...tection Mode MAN Selects Programme PROG Resets Unit to Default Settings RESET Blue Backlight Illuminates Display LIGHT Sets Time and Date DAY Selects Operation Mode HOLD Display Temporary Override Set...

Page 10: ...lay Time Display User Set Temperature Low Battery Warning Heating ON Display Room Temperature Holiday Mode Display Programme Events Display Manual Mode Display Symbols 9 2 3 4 5 6 7 8 9 1 Figure 1 Fig...

Page 11: ...e factory pre set settings press the SET button which will revert the thermostat to Run Mode the colon in the LCD display Mon Fri pre set time and temperature settings Sat Sun pre set time and tempera...

Page 12: ...ion is shown by 1 2 3 4 5 ashing 5 Day and 6 7 ashing 2 Day 24 hr operation is shown by 1 2 3 4 5 6 7 ashing 3 Press SET to lock in your selection Permanent Manual Overrides 1 To override the temperat...

Page 13: ...to decrease the set temperature in increments of 0 5 c 3 Once the desired temperature is reached and after approx 6 seconds the time display will be replaced by a display indicating the time left to...

Page 14: ...to set the number of days you will be away 4 Press PROG to con rm settings 5 Press SET to revert back to the main display The number of days chosen will alternate with time symbol on display 6 Once th...

Page 15: ...s the DAY button until the desired number of hours have been selected 1 to 9 Close the ap without pressing any other button 4 Press SET to cancel Frost Protection This function is provided as an optio...

Page 16: ...DAY once until the hour symbol is ashing Use or to adjust the hour 6 Press DAY once until the minute symbol is ashing use or to adjust the minutes 7 Press SET to con rm changes and return to run mode...

Page 17: ...o Run Mode Fig 7 Changing the Programme 5 2 Day Mon Fri 1 Press and hold SET then press PROG until the days of the week are ashing 1 2 3 4 5 6 7 2 Release SET button then press or until 1 2 3 4 5 Mon...

Page 18: ...ashing Fig 9 Press PROG once and the time will ash Fig 8 Use or to adjust the rst time to required setting 3 Press PROG once and the temperature will ash Fig 8 Use or to adjust the temperature 4 Repea...

Page 19: ...h Fig 10 Adjust the time for P1 using the buttons if required 3 Press PROG again and the temperature setting for P1 will ash Fig 10 Adjust the temperature if required 4 Repeat steps 2 and 3 for progra...

Page 20: ...s ashing 3 Press the button to arrive at the day that you want to copy to Press COPY 4 Press SET to lock in changes and return to Auto mode It is possible to copy Day 1 or 2 or 3 etc to 7 Day setting...

Page 21: ...located on the main part of the thermostat Remove the old batteries and insert new ones All settings including time are maintained N B If the display ever goes blank during normal operation the batter...

Page 22: ...y oon less The the new B If the ality to ting med Installer Instructions...

Page 23: ...mber of Events per Day BST GMT Time Change Factory Pre Set Programme Complies with 7 Day 5 2 Day 24Hr 2 x 1 5V Alkaline Batteries type AA size NTC 10k 1 at 25oC 0 2oC or 0oC 0 2oC 7oC to 34oC Thermopl...

Page 24: ...Fixing Power Supply Voltage Power Consumption Plastic Protection Rating Dimensions Complies with Easy Fit Back Plate 6W Thermoplastic ame retardant IP30 135mm L x 90mm W x 33mm D EN60730 1 EN 60730 2...

Page 25: ...s The recommended cable sizes are 1 0mm sqr or 1 5mm sqr No earth connection is required as the product is double insulated but ensure continuity of earth throughout the system General Safety Instruct...

Page 26: ...on the system And please read all instructions before proceeding Arrange for an annual maintenance and inspection sched ule to be carried out by a competent person on every part of the heating and ho...

Page 27: ...ernatively use the stand provided 3 Insert the 2 x AA batteries provided Fig 4 and replace the front cover of the thermostat Product Positioning 21 The ideal position to locate the Programmable Room T...

Page 28: ...22 Fig 1 Fig 2 Fig 3...

Page 29: ...ed and will automatically start to control the room temperature according to the factory pre set programme as shown in the User Instructions The display shows the correct time and date which is automa...

Page 30: ...the screws 4 Ensure an appropriate fuse is tted to the circuit before reconnecting to the mains supply Commissioning Con guring 1 If the receiver and thermostat have been supplied as a kit the units h...

Page 31: ...out 1 and 2 above again 5 If unsuccessful leave the unit powered on for 5 minutes and repeat the steps above M A MANUAL Figure 5 Fig 5 25...

Page 32: ...26 N B Volt free contacts Wiring Diagram Programmable Room Thermostat Receiver...

Page 33: ...FF the heating will turn ON M A red light comes on N B It is important to remember that the automatic control of the receiver is now o and the receiver will only respond to manual operations To return...

Page 34: ...is 0 2 C the display indicates this setting with symbol S 1 which can be modi ed to 0 0 2 C the display indicates this setting with symbol S 2 1 Press the SET button to go to the main screen 2 Press t...

Page 35: ......

Page 36: ...Version 3 1 ESi Controls Limited sales esicontrols co uk www esicontrols co uk...

Reviews: