Page 3: ...l 3 1 3 Off Frost Protection 5 3 2 All Day Mode AL 5 3 3 Holiday Mode HOLI 6 4 Main Menu 4 1 Copy Function CoPy 7 4 2 Backlight On Off LIGH 7 4 3 Resetting the Unit rESE 8 5 Programme Settings ProG 5...

Page 4: ...ructions 14 7 1 3 Warning Notices 15 7 1 4 Maintenance 15 7 2 1 Fitting the Programmable Room Thermostat 15 7 2 2 Installing the Programmable Room Thermostat 16 7 2 3 Wiring Diagram 17 8 Technical Set...

Page 5: ...me and date will need to be set Use the dial to adjust the hour then press Repeat this to set the minute day date and month date Next set the year by using the dial to adjust the first digit then pres...

Page 6: ...on mode Off Frost protection mode Manual operation mode Flame symbol when system calling for heat Cancels and returns to the previous menu Either confirms and saves the setting or moves you to next op...

Page 7: ...1 2 Quick Command Guide 2...

Page 8: ...nd hold until the display shows tINE then press 2 Turn the dial to adjust the hour then press 3 Turn the dial to adjust the minute then press 4 Turn the dial to adjust to the current day then press 5...

Page 9: ...range 5o C 35o C Default 21o C N B The temporary set temperature will not replace the original program event s set temperature When the program event ends it will return to the default heating program...

Page 10: ...e dial to desired temperature then press to confirm and automatically return to the homescreen Press in the homescreen to exit All Day mode and return to Auto mode 3 1 2 MAN Permanent manual override...

Page 11: ...splay will alternate between HOLI Days Holiday HOLI Current room temperature To adjust the settings in Holiday mode turn the dial to adjust holiday days press to confirm Then turn the dial to adjust s...

Page 12: ...ress and hold until the display shows tINE Turn the dial until display shows CoPy then press Use the dial to select the day to be copied then press to confirm Use the dial to select the day to be copi...

Page 13: ...If set permanently ON the light will automatically switch to a lower light setting and be dimmer 4 3 Resetting the Unit rESE Resetting the unit will return the thermostat to default setting The time d...

Page 14: ...ure settings 9 5 Programme Settings ProG 5 1 Factory Pre Set Programme This unit has been designed to be a simple to use thermostat requiring minimal user intervention with a pre programmed heating pr...

Page 15: ...ally return to homescreen 10 Choose 5 2 day operation see 5 2 for details Then press Turn the dial to select the days to programme either 1 5 for weekdays or 6 7 for weekends then press Turn the dial...

Page 16: ...i then press Turn the dial to choose the program P1 P6 Then press to enter time setting Turn the dial to adjust the time 10 minutes increments Then press to enter temperature setting Turn the dial to...

Page 17: ...Installa on Instruc ons...

Page 18: ...00 24 00 See 5 1 for details Program event set temperature 5o C 35o C See 5 1 for details Program operation mode 5 2 day 7 day 24hr Default 5 2 day Number of programs 4 or 6 Default 6 Manual mode temp...

Page 19: ...s Power supply 230VAC 3 1 A SPDT Temperature Sensor Type 1o C at 20o C Total Switch Rating 3 1 A 230 VAC Contact Type SPDT Volt Free changeover contacts Plastic Thermoplastic flame retardant Protectio...

Page 20: ...ired as the product is double insulated but ensure continuity of earth throughout the system 7 1 2 General Safety Instructions This product complies with the essential requirements of the follow ing E...

Page 21: ...oom Thermostat The ideal position to locate the Programmable Room Thermostat is about 1 5m above floor level in a location where the thermostat is accessible reasonably lit and free from extremes of t...

Page 22: ...t 1 Use a flat headed screwdriver to press the fastener at the top of the unit then gently loosen from the unit unhooking from top to bottom Fix the 35mm back box terminals at the top onto a 2 flange...

Page 23: ...al 4 NC Normally Closed 5 NO Normally Open 17 Route the wires through the back of the wall plate Fit the wires to the wall plate in accordance with the relevant diagram and in accordance with I E E re...

Page 24: ...8 Technical Settings 8 1 Quick Command Guide 18...

Page 25: ...nt room tempera ture tPI TPI Default is OFF Use the dial to choose between OFF function disabled 3CYC each hour has 3 heating cycles recommended for oil boilers or 6CYC each hour has 6 heating cycles...

Page 26: ...due by displaying SER in the screen 30 days before due date The operation of the system will not be affected 2 Reminds the user when the annual service is due by displaying SER in the screen 30 days b...

Page 27: ...9 1 and use the dial to select CODE then press Use the dial to set the first digit of the new password then press to move to the next digit Repeat this for all 4 digits On the last digit press to con...

Page 28: ...continuous product improvement we reserve the right to alter designs specifications and materials without prior notice and cannot accept liability for errors WARNING Interference with sealed parts ren...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...Version 6 9 3 ESi Controls Limited sales esicontrols co uk www esicontrols co uk...

Reviews: