The Factory Pre-Set Programme
This Channel Programmer has been designed to be simple
to use, requiring minimal user intervention with a pre-
programmed heating profile.
The pre-set heating times and temperatures will suit most
people
(see table below)
. To accept the factory pre-set settings,
move the slider to
RUN
which will revert the programmer to
Run Mode (the colon (:) in the LCD display will begin to flash).
N.B.
Every time the reset is pressed, the programmer will default
to prog1 boost only.
7 Day:
In 7 day setting, the pre-set settings are the same as 5/2 Day
programme (Mon to Fri and Sat/Sun).
24 Hr:
In 24hr setting, the pre-set settings are the same as Mon to Fri
of the 5/2 Day programme.
Programming the unit
(Only when in program 0)
Event
Std Time
Econ
Time
Std Time
Econ
Time
W
eek Days
1st ON
06:30
00:00
W
eek
ends
07:30
00:00
1st OFF
08:30
05:00
10:00
05:00
2nd ON
12:00
13:00
12:00
13:00
2nd OFF
12:00
16:00
12:00
16:00
3rd ON
17:00
20:00
17:00
20:00
3rd OFF
22:30
22:00
22:30
22:00
N.B.
If 2PU or 2GR is selected, then events 2nd ON and 2nd OFF
are skipped