esera automation 11325 User Manual Download Page 8

 
 
 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11325 V2.0 R1.0  Manual 

Page 8 of 8 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or 
disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed 
upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

) must be carried out. 

 

17 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship 
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of 
invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for 
damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations, 
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to 
this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. 
Claims made under the Product Liability Act are not affected. 
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is 
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. 
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical 
or electronic errors in the online offer. 
We are constantly developing our products further and reserve the right to make changes and improvements to any of the 
products described in this documentation without prior notice. Should you require documents or information on older 
versions, please contact us by e-mail at 

[email protected]

 

 

 

18 

Trademarks 

All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are 
trademarks, registered trademarks or other copyright or trademarks or titles or legally protected designations of their 
respective owners and are hereby expressly recognized as such by us. The mention of these designations, logos, names 
and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA 
GmbH on these designations, logos, names and trademarks. Moreover, from their appearance on ESERA GmbH 
webpages it cannot be concluded that designations, logos, names and trademarks are free of commercial property rights. 

ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH. 

 

19 

Contact 

ESERA GmbH 
Adelindastrasse 20 
87600 Kaufbeuren 
GERMANY 
Tel.: +49 8341 999 80-0 
Fax: +49 8341 999 80-10 

www.esera.de

 

[email protected]

 

WEEE-Number: DE30249510

 

 

Summary of Contents for 11325

Page 1: ...to worry about 1 Wire commands or formulas for evaluating sensor data The controller independently scans the 1 Wire network for devices sensors and actuators and depending on the device found outputs the corresponding data in plain text Formatted data output The 1 Wire Controller 1 provides the sensor and actuator data ready prepared e g for temperature sensors in C cyclically off Only one divisio...

Page 2: ...F EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 interference immunity EN 61000 6 3 interference radiation RoHS 6 Software In order to protect controller 1 from unauthorized access a password key must be entered before a data connection is established This signals to Controller 1 that the connection setup is an authorized access The factory default is key 1304 7 Setting up Bluetooth A Bluetoot...

Page 3: ...e Controller 1 RFCOMM channel for the connection channel 1 Description of the connection comment 1 Wire_Controller1 Device must of course be adapted rfcomm connect 00 12 6F 2B B1 52 execute in the console Now the serial interface can be accessed with a normal terminal program dev rfcomm0 8 Display LED The module has various display LEDs In the following the function of the displays Display Bezeich...

Page 4: ... ESERA GmbH ESERA Automation 2020 www esera de 11325 V2 0 R1 0 Manual Page 4 of 8 9 Connection diagram Module top side 1 Wire Bus Module top side 7 ground 1 Wire 8 1 Wire Data 9 5V output Module bottom side power supply 1 Minus Supply voltage 2 Plus Supply voltage Note Basics and tips for the 1 Wire Bus system can be found in our eBook in the shop at http www esera de schulung support dokumentatio...

Page 5: ...es the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11325 V2 0 R1 0 Manual Page 5 of 8 10 Connection example 1 Wire Hub III sensors and actuators Der 1 Wire Controller 1 Ethernet is shown here as an example of the 1 Wire Controller 1 Bluetooth ...

Page 6: ...Tool 3 in the form of a COM interface You can find this program in the download area of the ESERA Online shop Configuration and Communication with 1 Wire Controller 1 The 1 Wire Controller 1 has extensive configuration and formatting options that can be read and operated with the ESERA Config Tool 3 Since communication between the 1 Wire controller 1 and the Config tool 3 takes place via the open ...

Page 7: ...id VDE regulations must be observed especially VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the unit is disconnected from the mains Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they...

Page 8: ...ample for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from unauthorized usage and other legal grounds are excluded Excepting to this ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If defects occur f...

Reviews: