background image

Art. No. 11211 
 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11211 V2.0 R1.0  Manual 

Page 7 of 7

 

 

21 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship defects 
and have the contractually assured characteristics. The statutory warranty period of two years begins from date of invoice. 
The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for damages, for 
example, for non-performance, fault in contracting, breach of secondary contractual obligations, consequential damages, 
damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to this, ESERA GmbH accepts 
liability for the absence of a guaranteed quality resulting from intent or gross negligence. Claims made under the Product 
Liability Act are not affected. 
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is faulty, 
the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. 
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or 
electronic errors in the online offer. 
We are constantly developing our products further and reserve the right to make changes and improvements to any of the 
products described in this documentation without prior notice. Should you require documents or information on older 
versions, please contact us by e-mail a

[email protected]

 

 

22 

Trademarks 

All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are trademarks, 
registered trademarks or other copyright or trademarks or titles or legally protected designations of their respective owners 
and are hereby expressly recognized as such by us. The mention of these designations, logos, names and trademarks is 
made for identification purposes only and does not represent a claim of any kind on the part of ESERA GmbH on these 
designations, logos, names and trademarks. Moreover, from their appearance on ESERA GmbH webpages it cannot be 
concluded that designations, logos, names and trademarks are free of commercial property rights. 

ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH. 

 

23 

Contact 

ESERA GmbH 
Adelindastrasse 20 
87600 Kaufbeuren 
GERMANY 
Tel.: +49 8341 999 80-0

 

Fax: +49 8341 999 80-10

 

www.esera.de

 

[email protected]

 

WEEE-Number: DE30249510

 

 

 

Summary of Contents for 11211

Page 1: ...lectricity water and gas meters or wind turbines All S0 devices manufactured according to DIN 43864 can be equipped with an isolated S0 interface can be connected If in doubt check the data sheet of your energy measuring device After applying the operating voltage the Dual S0 counter module is ready for operation The integrated Counter modules count the input pulses continuously The counter readin...

Page 2: ... 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 Interference immunity EN 61000 6 3 Interference radiation RoHS 6 LED display The module has two yellow LED displays which flash when an input is being closed When the input is open a 5V power is measurable The edge is being counted during the closing of the input A continuously closed input does not cause a modification of the counter read...

Page 3: ...und for example on the Wikipedia website https en wikipedia org wiki Electricity_meter https de wikipedia org wiki S0 Schnittstelle 10 Data output 1 Wire Controller 1 Wire Gateway For the Dual S0 counter module the following data of the 32Bit counter values are output The 1 Wire interface of the Dual S0 counter module is controlled by standard commands for the DS2423 block and the data is read out...

Page 4: ...written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11211 V2 0 R1 0 Manual Page 4 of 7 12 Connection example 1 Combination of AC meter and Dual S0 counter module 13 Connection example 2 Combination of three phase meter and Dual S0 counter module ...

Page 5: ...echnical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11211 V2 0 R1 0 Manual Page 5 of 7 14 Connection example 3 Combination of wind sensor and Dual S0 counter module 15 Connection example 4 The following example shows the combination of 1 Wire Controller 20 1 Wire Gateway 20 Modbus 1 Wire Analog Input Module and 1 Wire S0 Dual Counter Module ...

Page 6: ...r applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged Live cables or wires to which the device or an assembly is connected must always be tested for insulation faults or breaks If an error is detected in the supply line the...

Page 7: ...urchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We are constantly developing our products further and reserve the right to make changes and improvements to any of the products described in this documentation without prior notic...

Reviews: